The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Wearable Temperature Sensors with Enhanced Sensitivity by Engineering Microcrack Morphology in PEDOT:PSS–PDMS Sensors
Abstract
Wearable temperature sensors with high sensitivity, linearity, and flexibility are required to meet the increasing demands for unobtrusive monitoring of temperature changes indicative of the onset of infections and diseases. Herein, we present a new method for engineering highly sensitive and flexible temperature sensors made by sandwiching a poly(3,4-ethylenedioxythiophene):polystyrene (PEDOT:PSS) sensing film between two poly(dimethylsiloxane) (PDMS) substrates. Pre-stretching the sensor to a certain strain can create stable microcracks in the sensing layer that bestow high senstivity and linearity. The average length and density of the microcracks, which dictate the sensor’s temperature sensitivity, can be engineered by controlling three key processing parameters, incuding (a) pre-stretching strain, (b) sulfuric acid treatment time, and (c) surface roughness of the substrate. For a given acid treatment time and surface roughness condition, the density and average length of the microcracks increase pre-stretching strain. A smooth PDMS substrate tends to yield long and straight cracks in the PEDOT:PSS film, compared to shorter microcracks with higher density on rough surfaces. Crack density can be further increased via sulfuric acid treatment with an optimum duration of approximately 3 h. Prolonged treatment would result in weak adhesion between the PEDOT:PSS film and the PDMS substrate, which in turn reduces the microcrack density but increases the crack length. By optimizing the three design parameters we have designed a high performance PEDOT:PSS–PDMS sensor that provides a combined high temperature sensitivity of 0.042 °C –1 with an excellent linearity of 0.998 (from 30 to 55 °C), better than the highest temperature sensitivity of PEDOT:PSS based sensors reported in the literature. With a good optical transparency, high temperature sensitivity, excellent linearity, and high flexibility, this microcrack-based sensor is a very promising wearable temperature-sensing solution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Ultrathin conformal devices for precise and continuous thermal characterization of human skin
Webb, R. C., Bonifas, A. P., Behnaz, A., Zhang, Y., Yu, K. J., Cheng, H., Shi, M., Bian, Z., Liu, Z., Kim, Y.-S., et al. (2013) · Nature Materials · doi:10.1038/nmat3755 · Cited by 1,229
Recent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104
Trung, T. Q., Ramasundaram, S., Hwang, B., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504441 · Cited by 870
A Flexible Bimodal Sensor Array for Simultaneous Sensing of Pressure and Temperature
Tien, N. T., Jeon, S., Kim, D., Trung, T. Q., Jang, M., Hwang, B., Byun, K., Bae, J., Lee, E., Tok, J. B. ‐., et al. (2014) · Advanced Materials · doi:10.1002/adma.201302869 · Cited by 438
Ultraflexible, large-area, physiological temperature sensors for multipoint measurements
Yokota, T., Inoue, Y., Terakawa, Y., Reeder, J., Kaltenbrunner, M., Ware, T., Yang, K., Mabuchi, K., Murakawa, T., Sekino, M., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1515650112 · Cited by 382
Stretchable Graphene Thermistor with Tunable Thermal Index
Yan, C., Wang, J., & Lee, P. S. (2015) · ACS Nano · doi:10.1021/nn507441c · Cited by 359
Kanao, K., Harada, S., Yamamoto, Y., Honda, W., Arie, T., Akita, S., & Takei, K. (2015) · RSC Advances · doi:10.1039/c5ra03110a · Cited by 148
Cited by
Transparent Electronics for Wearable Electronics Application
Won, D., Bang, J., Choi, S. H., Pyun, K. R., Jeong, S., Lee, Y., & Ko, S. H. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00139 · Cited by 339
Su, Y., Ma, C., Chen, J., Wu, H., Luo, W., Peng, Y., Luo, Z., Li, L., Tan, Y., Omisore, O. M., et al. (2020) · Nanoscale Research Letters · doi:10.1186/s11671-020-03428-4 · Cited by 287
Metadata
- Authors
- Yu, Y., Peng, S., Blanloeuil, P., Wu, S., & Wang, C. H.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-07-15
- Volume
- 12
- Issue
- 32
- Pages
- 36578-36588
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W3043157317
- Cited by
- 164
- References
- 9
- FWCI
- 6.34
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.