Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Wearable Temperature Sensors with Enhanced Sensitivity by Engineering Microcrack Morphology in PEDOT:PSS–PDMS Sensors

Yu, Yuyan, Peng, Shuhua, Blanloeuil, Philippe, Wu, Shuying, Wang, Chun H. · 2020 · ACS Applied Materials & Interfaces

Abstract

Wearable temperature sensors with high sensitivity, linearity, and flexibility are required to meet the increasing demands for unobtrusive monitoring of temperature changes indicative of the onset of infections and diseases. Herein, we present a new method for engineering highly sensitive and flexible temperature sensors made by sandwiching a poly(3,4-ethylenedioxythiophene):polystyrene (PEDOT:PSS) sensing film between two poly(dimethylsiloxane) (PDMS) substrates. Pre-stretching the sensor to a certain strain can create stable microcracks in the sensing layer that bestow high senstivity and linearity. The average length and density of the microcracks, which dictate the sensor’s temperature sensitivity, can be engineered by controlling three key processing parameters, incuding (a) pre-stretching strain, (b) sulfuric acid treatment time, and (c) surface roughness of the substrate. For a given acid treatment time and surface roughness condition, the density and average length of the microcracks increase pre-stretching strain. A smooth PDMS substrate tends to yield long and straight cracks in the PEDOT:PSS film, compared to shorter microcracks with higher density on rough surfaces. Crack density can be further increased via sulfuric acid treatment with an optimum duration of approximately 3 h. Prolonged treatment would result in weak adhesion between the PEDOT:PSS film and the PDMS substrate, which in turn reduces the microcrack density but increases the crack length. By optimizing the three design parameters we have designed a high performance PEDOT:PSS–PDMS sensor that provides a combined high temperature sensitivity of 0.042 °C –1 with an excellent linearity of 0.998 (from 30 to 55 °C), better than the highest temperature sensitivity of PEDOT:PSS based sensors reported in the literature. With a good optical transparency, high temperature sensitivity, excellent linearity, and high flexibility, this microcrack-based sensor is a very promising wearable temperature-sensing solution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.0c07649

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Yu, Y., Peng, S., Blanloeuil, P., Wu, S., & Wang, C. H.
Venue
ACS Applied Materials & Interfaces
Published
2020-07-15
Volume
12
Issue
32
Pages
36578-36588
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3043157317
Cited by
164
References
9
FWCI
6.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.