Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 173

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

High-Resolution and High-Sensitivity Flexible Capacitive Pressure Sensors Enhanced by a Transferable Electrode Array and a Micropillar–PVDF Film

Luo, Zebang, Chen, Jing, Zhu, Zhengfang, Li, Lin, Su, Yi, Tang, Wei, Omisore, Olatunji Mumini, Wang, Lei, Li, Hui·2021·ACS Applied Materials & Interfaces

Abstract

Flexible pressure sensors have attracted increasing attention because they can mimic human skin to sense external pressure; however, for mimicking human skin, the sensing of a pressure point is far from sufficient. To realize fully biomimetic skins, it is crucial for flexible sensors to have high resolution and high sensitivity. We conducted simulations and experiments to determine the relationship between the sensor sensitivity and physical parameters, such as the effective relative permittivity and air ratio of the dielectric layer. According to the results, a micropillar–poly(vinylidene fluoride) (PVDF) dielectric layer was designed to achieve high sensitivity (0.43 kPa –1 ) in the low-pressure regime (<1 kPa). An 8 × 8 pixel sensor matrix was prepared based on a micropillar–PVDF (MP) film and electrode array (MPEA) to detect the pressure distribution with high resolution (13 dpi). Each pixel could reflect the point of applied pressure through an obvious change in the relative capacitance; moreover, objects with various geometries could be mapped by the pixels of the flexible sensor. A counterweight, a plastic flag, and pine leaves were placed on the flexible sensor, and the shapes were successfully mapped; in particular, the mapping of the ∼0.005 g ultra-lightweight pine leaves with a length of 7 mm and a width of 0.6 mm shows the high sensitivity and high resolution of our flexible pressure sensor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.0c23042

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 173

Metadata

Authors
Luo, Z., Chen, J., Zhu, Z., Li, L., Su, Y., Tang, W., Omisore, O. M., Wang, L., & Li, H.
Venue
ACS Applied Materials & Interfaces
Published
2021-02-04
Volume
13
Issue
6
Pages
7635-7649
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W3128935756
Cited by
173
References
5
FWCI
8.75
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Resolution and High-Sensitivity Flexible Capacitive Pressure Sensors Enhanced by a Transferable Electrode Array and a Micropillar–PVDF Film. https://app.cochat.ai/papers/10.1021/acsami.0c23042
The paper
Luo, Z., Chen, J., Zhu, Z., Li, L., Su, Y., Tang, W., Omisore, O. M., Wang, L., & Li, H. (2021). High-Resolution and High-Sensitivity Flexible Capacitive Pressure Sensors Enhanced by a Transferable Electrode Array and a Micropillar–PVDF Film. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.0c23042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.