Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 255

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat

Li, Quan-Fu, Chen, Xu, Wang, Hai, Liu, Ming, Peng, Hui-Ling·2023·ACS Applied Materials & Interfaces

Abstract

Wearable non-invasive sensors facilitate the continuous measurement of glucose in sweat for the treatment and management of diabetes. However, the catalysis of glucose and sweat sampling are challenges in the development of efficient wearable glucose sensors. Herein, we report a flexible wearable non-enzymatic electrochemical sensor for continuous glucose detection in sweat. We synthesized a catalyst (Pt/MXene) by the hybridization of Pt nanoparticles onto MXene (Ti 3 C 2 T x ) nanosheets with a broad linear range of glucose detection (0–8 mmol/L) under neutral conditions. Furthermore, we optimized the structure of the sensor by immobilizing Pt/MXene with a conductive hydrogel to enhance the stability of the sensor. Based on Pt/MXene and the optimized structure, we fabricated a flexible wearable glucose sensor by integrating a microfluidic patch for sweat collection onto a flexible sensor. We evaluated the utility of the sensor for the detection of glucose in sweat, and the sensor could detect the glucose change with the replenishment and consumption of energy by the body, and a similar trend was observed in the blood. An in vivo glucose test in sweat indicated that the fabricated sensor is promising for the continuous measurement of glucose, which is essential for the treatment and management of diabetes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.2c20543

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Metadata

Authors
Li, Q.-F., Chen, X., Wang, H., Liu, M., & Peng, H.-L.
Venue
ACS Applied Materials & Interfaces
Published
2023-03-02
Volume
15
Issue
10
Pages
13290-13298
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W4322757968
Cited by
255
References
31
FWCI
18.69
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat. https://app.cochat.ai/papers/10.1021/acsami.2c20543
The paper
Li, Q.-F., Chen, X., Wang, H., Liu, M., & Peng, H.-L. (2023). Pt/MXene-Based Flexible Wearable Non-Enzymatic Electrochemical Sensor for Continuous Glucose Detection in Sweat. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.2c20543

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.