Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 235

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Laser-induced graphene non-enzymatic glucose sensors for on-body measurements

Open access
Zhu, Jia, Liu, Shangbin, Hu, Zhihui, Zhang, Xianzhe, Yi, Ning, Tang, Kairui, Dexheimer, Michael Gregory, Lian, Xiaojun, Wang, Qing, Yang, Jian, Gray, Jennifer, Cheng, Huanyu·2021·Biosensors and Bioelectronics

Abstract

Non-enzymatic glucose sensors outperform enzymatic ones in terms of cost, sensitivity, stability, and operating duration. Though highly sensitive, it is still desirable to further improve the sensitivity of non-enzymatic glucose sensors to detect a trace amount of glucose in sweat and other biofluids. Among the demonstrated effective approaches using bimetals or 3D porous structures, the porous laser-induced graphene (LIG) on flexible polymers showcases good conductivity and a simple fabrication process for the integration of sensing materials. The uniform electroless plating of the nickel and gold layer on LIG electrodes demonstrates significantly enhanced sensitivity and a large linear range for glucose sensing. The sensor with the porous LIG foam exhibits a high sensitivity of 1080 μA mM−1 cm−2, whereas a further increased sensitivity of 3500 μA mM−1 cm−2 is obtained with LIG fibers (LIGF). Impressively, a large linear range (0 – 30 mM) can be achieved by changing the bias voltage from 0.5 to 0.1 V due to the Au coating. Because the existing non-enzymatic glucose sensors are limited to use in basic solutions, their application in wearable electronics is elusive. In addition to the reduced requirement for the base solution, this work integrates a porous encapsulating reaction cavity containing alkali solutions with a soft, skin-interfaced microfluidic component to provide integrated microfluidic non-enzymatic glucose sensors for sweat sampling and glucose sensing. The accurate glucose measurements from the human sweat and cell culture media showcase the practical utility, which opens up opportunities for the non-enzymatic glucose sensors in wearable electronics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.bios.2021.113606

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 235

Metadata

Authors
Zhu, J., Liu, S., Hu, Z., Zhang, X., Yi, N., Tang, K., Dexheimer, M. G., Lian, X., Wang, Q., Yang, J., Gray, J., & Cheng, H.
Venue
Biosensors and Bioelectronics
Publisher
Elsevier BV
Published
2021-12
Volume
193
Pages
113606
ISSN
0956-5663 (ISSN-L)
OpenAlex
W3197321815
Cited by
235
References
4
FWCI
11.16
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Laser-induced graphene non-enzymatic glucose sensors for on-body measurements. https://app.cochat.ai/papers/10.1016/j.bios.2021.113606
The paper
Zhu, J., Liu, S., Hu, Z., Zhang, X., Yi, N., Tang, K., Dexheimer, M. G., Lian, X., Wang, Q., Yang, J., Gray, J., & Cheng, H. (2021). Laser-induced graphene non-enzymatic glucose sensors for on-body measurements. Biosensors and Bioelectronics. https://doi.org/10.1016/j.bios.2021.113606

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.