Appropriate Size of Magnetic Nanoparticles for Various Bioapplications in Cancer Diagnostics and Therapy
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
The development of multifunctional nanoparticles has attracted increasing attention. The versatility of nanoparticles largely depends on their physiochemical properties (especially size). However, the optimized size range may be different for the bioapplications of each function associated with multifunctional nanoparticles. It is important to investigate every optimized size range to ascertain which size enables the best function of the nanoparticles before deciding their final size. In this work, we synthesized a series of monodisperse Fe3O4 nanoparticles with identical surface properties ranging in size from 60 to 310 nm and systematically investigated their biobehavior and application. Our data indicate that compared to their large counterparts, small Fe3O4 nanoparticles exhibited greater cellular internalization and deeper penetration into multicellular spheroids, thus enabling a higher photothermal ablation efficacy in vitro. Interestingly, larger Fe3O4 nanoparticles showed greater accumulation in tumors, thereby inducing more efficient tumor growth inhibition. In addition, 120 nm may be the optimal diameter of Fe3O4 nanoparticles for magnetic resonance imaging and photoacoustic tomography in vitro. However, more efficient in vivo imaging mediated by Fe3O4 nanoparticles will predominantly depend on their high accumulation. Our work presents a different appropriate size range for each biofunction of Fe3O4 nanoparticles, which could be a valuable reference for future nanoparticle design.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laurent, S., Forge, D., Port, M., Roch, A., Robic, C., Vander Elst, L., & Muller, R. N. (2008) · Chemical Reviews · doi:10.1021/cr068445e · Cited by 6,852
Recent advances with liposomes as pharmaceutical carriers
Torchilin, V. P. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1632 · Cited by 5,282
Photoacoustic tomography: In vivo imaging from organelles to organs
Wang, L. V., & Hu, S. (2012) · Science · doi:10.1126/science.1216210 · Cited by 4,331
Nanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233
The effect of particle design on cellular internalization pathways
Gratton, S. E. A., Ropp, P. A., Pohlhaus, P. D., Luft, J. C., Madden, V. J., Napier, M. E., & DeSimone, J. M. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801763105 · Cited by 2,918
He, C., Hu, Y., Yin, L., Tang, C., & Yin, C. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.065 · Cited by 2,607
Accumulation of sub-100 nm polymeric micelles in poorly permeable tumours depends on size
Cabral, H., Matsumoto, Y., Mizuno, K., Chen, Q., Murakami, M., Kimura, M., Terada, Y., Kano, M. R., Miyazono, K., Uesaka, M., et al. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.166 · Cited by 2,429
Multifunctional Magnetic Nanoparticles: Design, Synthesis, and Biomedical Applications
Gao, J., Gu, H., & Xu, B. (2009) · Accounts of Chemical Research · doi:10.1021/ar9000026 · Cited by 1,907
Spheroid-based drug screen: Considerations and practical approach
Friedrich, J., Seidel, C., Ebner, R., & Kunz-Schughart, L. A. (2009) · Nature Protocols · doi:10.1038/nprot.2008.226 · Cited by 1,742
Cited by
Iron Oxide Nanoparticles in Photothermal Therapy
Estelrich, J., & Busquets, M. A. (2018) · Molecules · doi:10.3390/molecules23071567 · Cited by 354
Ansari, S. A. M. K., Ficiarà, E., Ruffinatti, F. A., Stura, I., Argenziano, M., Abollino, O., Cavalli, R., Guiot, C., & D’Agata, F. (2019) · Materials · doi:10.3390/ma12030465 · Cited by 274
Huang, B.-W., & Gao, J.-Q. (2018) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.12.005 · Cited by 174
Bauleth-Ramos, T., Feijão, T., Gonçalves, A., Shahbazi, M.-A., Liu, Z., Barrias, C., Oliveira, M. J., Granja, P., Santos, H. A., & Sarmento, B. (2020) · Journal of Controlled Release · doi:10.1016/j.jconrel.2020.04.025 · Cited by 79
“For example, NPs larger than 100 nm have shown limited penetration in MCTS, accumulating preferentially in the periphery [71, 72].”
Background3D Tumor Spheroid Models for In Vitro Therapeutic Screening of Nanoparticles
Daunys, S., Janonienė, A., Januškevičienė, I., Paškevičiūtė, M., & Petrikaitė, V. (2021) · Advances in experimental medicine and biology · doi:10.1007/978-3-030-58174-9_11 · Cited by 32
Metadata
- Authors
- Guo, X., Wu, Z., Li, W., Wang, Z., Li, Q., Kong, F., Zhang, H., Zhu, X., Du, Y. P., Jin, Y., Du, Y., & You, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2016-01-27
- Volume
- 8
- Issue
- 5
- Pages
- 3092-3106
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2233779473
- Cited by
- 117
- References
- 9
- FWCI
- 5.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Appropriate Size of Magnetic Nanoparticles for Various Bioapplications in Cancer Diagnostics and Therapy. https://app.cochat.ai/papers/10.1021/acsami.5b10352
- The paper
- Guo, X., Wu, Z., Li, W., Wang, Z., Li, Q., Kong, F., Zhang, H., Zhu, X., Du, Y. P., Jin, Y., Du, Y., & You, J. (2016). Appropriate Size of Magnetic Nanoparticles for Various Bioapplications in Cancer Diagnostics and Therapy. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.5b10352
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.