CoChat

Single and Networked ZnO–CNT Hybrid Tetrapods for Selective Room-Temperature High-Performance Ammonia Sensors

Open access
Schütt, Fabian, Postica, Vasile, Adelung, Rainer, Lupan, Oleg · 2017 · ACS Applied Materials & Interfaces
Cited by 141

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Highly porous hybrid materials with unique high-performance properties have attracted great interest from the scientific community, especially in the field of gas-sensing applications. In this work, tetrapodal-ZnO (ZnO-T) networks were functionalized with carbon nanotubes (CNTs) to form a highly efficient hybrid sensing material (ZnO-T–CNT) for ultrasensitive, selective, and rapid detection of ammonia (NH 3 ) vapor at room temperature. By functionalizing the ZnO-T networks with 2.0 wt % of CNTs by a simple dripping procedure, an increase of 1 order of magnitude in response (from about 37 to 330) was obtained. Additionally, the response and recovery times were improved (by decreasing them from 58 and 61 s to 18 and 35 s, respectively). The calculated lowest detection limit of 200 ppb shows the excellent potential of the ZnO-T–CNT networks as NH 3 vapor sensors. Room temperature operation of such networked ZnO–CNT hybrid tetrapods shows an excellent long-time stability of the fabricated sensors. Additionally, the gas-sensing mechanism was identified and elaborated based on the high porosity of the used three-dimensional networks and the excellent conductivity of the CNTs. On top of that, several single hybrid microtetrapod-based devices were fabricated (from samples with 2.0 wt % CNTs) with the help of the local metal deposition function of a focused ion beam/scanning electron microscopy instrument. The single microdevices are based on tetrapods with arms having a diameter of around 0.35 μm and show excellent NH 3 sensing performance with a gas response ( I gas / I air ) of 6.4. Thus, the fabricated functional networked ZnO–CNT hybrid tetrapods will allow to detect ammonia and to quantify its concentration in automotive, environmental monitoring, chemical industry, and medical diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.7b03702

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

Metadata

Authors
Schütt, F., Postica, V., Adelung, R., & Lupan, O.
Venue
ACS Applied Materials & Interfaces
Published
2017-06-27
Volume
9
Issue
27
Pages
23107-23118
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2727239280
Cited by
141
References
1
FWCI
7.61
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.