CoChat

Flexible Single-Electrode Triboelectric Nanogenerator and Body Moving Sensor Based on Porous Na2CO3/Polydimethylsiloxane Film

Cui, Chunmei, Wang, Xingzhao, Yi, Zhiran, Yang, Bin, Wang, Xiaolin, Chen, Xiang, Liu, Jingquan, Yang, Chunsheng · 2018 · ACS Applied Materials & Interfaces

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Abstract

Triboelectric nanogenerators (TENGs) converting mechanical energy into electrical energy have received much attention because of their huge potential applications for supplying power to electronic devices. Improving the performance of TENGs has become a research hot point because of their output limited current. In this paper, we propose a flexible single-electrode triboelectric nanogenerator based on porous Na 2 CO 3 /polydimethylsiloxane (PDMS) structure to enhance the triboelectric performance for nanogenerators. To compare their output performance, NaCl and sugar are normally used as sacrificial template for triboelectric nanogenerator. As an experimental result, the nanogenerator based on porous Na 2 CO 3 /PDMS structure obtains the open-circuit voltage of 125 V and maximum output current of 100 μA, which are higher than that generated by NaCl/PDMS and sugar/PDMS TENGs. And the generated electric energy of Na 2 CO 3 /PDMS TENG could instantaneously power 42 commercial light-emitting diodes without any energy storage devices. This developed porous Na 2 CO 3 /PDMS TENG could open a new application field for self-powered personal electronics because of its flexibility, simple manufacturing process, and the ability to harvest mechanical energy from human motions.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsami.7b17585

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 48 references

Research works printed but not linked: 1

  1. 10.1016/j.nanoen.2014.12.009 · DOI

Cited by

See all 136

Metadata

Authors
Cui, C., Wang, X., Yi, Z., Yang, B., Wang, X., Chen, X., Liu, J., & Yang, C.
Affiliations
Shanghai Jiao Tong University (CN)
Corresponding author
Yang, Bin
Venue
ACS Applied Materials & Interfaces
Published
2018-01-16
Volume
10
Issue
4
Pages
3652-3659
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2783608365
Cited by
134
References
48
Citations by year
2026: 12 · 2025: 9 · 2024: 15 · 2023: 12 · 2022: 11 · 2021: 26 · 2020: 21 · 2019: 21 · 2018: 7
FWCI
7.51
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Applied Materials & Interfaces (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Science and Technology of the People's Republic of China (2015AA043503)
  • Shanghai Municipal Education Commission (14ZZ019)
  • National Natural Science Foundation of China (61674104)
  • Shanghai Committee of Science and Technology of China (14DZ1940305)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
  • Physical Sciences › Engineering › Mechanics of Materials › Tribology and Wear Analysis
Keywords
triboelectric nanogenerator, single-electrode TENG, flexible energy harvesting, sacrificial template, mechanical-to-electrical energy conversion, self-powered devices, open-circuit voltage, output current

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Flexible Single-Electrode Triboelectric Nanogenerator and Body Moving Sensor Based on Porous Na2CO3/Polydimethylsiloxane Film. https://app.cochat.ai/papers/10.1021/acsami.7b17585
The paper
Cui, C., Wang, X., Yi, Z., Yang, B., Wang, X., Chen, X., Liu, J., & Yang, C. (2018). Flexible Single-Electrode Triboelectric Nanogenerator and Body Moving Sensor Based on Porous Na2CO3/Polydimethylsiloxane Film. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.7b17585

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.