The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Flexible and Highly Sensitive Resistive Pressure Sensor Based on Carbonized Crepe Paper with Corrugated Structure
Abstract
Recently, cellulose paper based materials have emerged for applications in wearable “green” electronics due to their earth abundance, low cost, light weight, flexibility, and sustainability. Herein, for the first time, we develop an almost all cellulose paper based pressure sensor through a facile, cost-effective, scalable, and environment-friendly approach. The screen-printed interdigital electrodes on the flat printing paper and the carbonized crepe paper (CCP) with good conductivity are integrated into a flexible pressure sensor as substrates and active materials, respectively. The porous and corrugated structure of the CCP endows the pressure sensor with high sensitivity (2.56–5.67 kPa –1 in the range of 0–2.53 kPa), wide workable pressure range (0–20 kPa), fast response time (<30 ms), low detection limit (∼0.9 Pa), and good durability (>3000 cycles). Additionally, we demonstrate the practical applications of the CCP pressure sensor in detection of finger touching, wrist pulse, respiration, phonation, acoustic vibration, etc., and real-time monitoring of spatial pressure distribution. The proposed CCP pressure sensor has great potentials in various applications as wearable electronics. Moreover, the subtle fabrication of the desired materials based on commercially available products provides new insights into the development of green electronics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kim, D.-H., Lu, N., Ma, R., Kim, Y.-S., Kim, R.-H., Wang, S., Wu, J., Won, S. M., Tao, H., Islam, A., et al. (2011) · Science · doi:10.1126/science.1206157 · Cited by 4,836
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Schwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
A flexible and highly sensitive strain-gauge sensor using reversible interlocking of nanofibres
Pang, C., Lee, G.-Y., Kim, T.-I., Kim, S. M., Kim, H. N., Ahn, S.-H., & Suh, K.-Y. (2012) · Nature Materials · doi:10.1038/nmat3380 · Cited by 1,695
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Park, J., Lee, Y., Hong, J., Ha, M., Jung, Y.-D., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn500441k · Cited by 915
Carbonized Silk Nanofiber Membrane for Transparent and Sensitive Electronic Skin
Wang, Q., Jian, M., Wang, C., & Zhang, Y. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605657 · Cited by 549
Cited by
Zheng, Y., Yin, R., Zhao, Y., Liu, H., Zhang, D., Shi, X., Zhang, B., Liu, C., & Shen, C. (2021) · Chemical Engineering Journal · doi:10.1016/j.cej.2020.127720 · Cited by 469
All Paper-Based Flexible and Wearable Piezoresistive Pressure Sensor
Gao, L., Zhu, C., Li, L., Zhang, C., Liu, J., Yu, H.-D., & Huang, W. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b07465 · Cited by 365
Wearable Pressure Sensors Based on MXene/Tissue Papers for Wireless Human Health Monitoring
Yang, L., Wang, H., Yuan, W., Li, Y., Gao, P., Tiwari, N., Chen, X., Wang, Z., Niu, G., & Cheng, H. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c22001 · Cited by 283
Shi, Z., Meng, L., Shi, X., Li, H., Zhang, J., Sun, Q., Liu, X., Chen, J., & Liu, S. (2022) · Nano-Micro Letters · doi:10.1007/s40820-022-00874-w · Cited by 282
Cutting-Edge Perovskite-Based Flexible Pressure Sensors Made Possible by Piezoelectric Innovation
Naz, A., Meng, Y., Luo, J., Khan, I. A., Abbas, R., Yu, S., & Wei, J. (2024) · Materials · doi:10.3390/ma17174196 · Cited by 14
Metadata
- Authors
- Chen, S., Song, Y., & Xu, F.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-09-18
- Volume
- 10
- Issue
- 40
- Pages
- 34646-34654
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2890299014
- Cited by
- 176
- References
- 9
- FWCI
- 6.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.