Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 169

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Improved Piezoelectric Sensing Performance of P(VDF–TrFE) Nanofibers by Utilizing BTO Nanoparticles and Penetrated Electrodes

Hu, Xiaohe, Yan, Xing, Gong, Longlong, Wang, Feifei, Xu, Yuanhang, Feng, Lin, Zhang, Deyuan, Jiang, Yonggang·2019·ACS Applied Materials & Interfaces

Abstract

Piezoelectric polymers with good flexibility have attracted tremendous attention in wearable sensors and energy harvesters. As the piezoelectricity of polymers such as polyvinylidene fluoride (PVDF) and polyvinylidene fluoride–trifluoroethylene [P(VDF–TrFE)] is lower than that of their ceramic counterparts, various approaches have been employed to improve the piezoelectric output of PVDF-based sensors, such as electrospinning, heat annealing, nanoconfinement, polymer blending, and nanoparticle addition. Here, we report two strategies to improve the piezoelectric sensing performance of polymer-based piezoelectric nanofibers, which include the formation of barium titanate (BTO)/P(VDF–TrFE) composite nanofibers and fabrication of penetrated electrodes to enlarge the interfacial area. BTO/P(VDF–TrFE) nanofibers with a BTO weight fraction of 5 wt % exhibit the maximum β-phase crystallinity and piezoelectricity. The piezoelectric output of the BTO/P(VDF–TrFE) nanofiber mat is significantly improved compared with that of pristine P(VDF–TrFE), which is confirmed by piezoresponse force microscopy (PFM) and compression loading tests. In order to form the penetrated electrodes, oxygen (O 2 ) plasma treatment is employed, followed by an electroless plating process. The BTO/P(VDF–TrFE) nanofibers with penetrated electrodes demonstrate increased dielectric constants and enhanced piezoelectric outputs. A BTO/P(VDF–TrFE) nanofiber-based sensor with penetrated electrodes is capable of discerning the energy of a free-falling ball as low as 0.6 μJ and sensing the movement of a walking ant.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.8b19824

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 169

Metadata

Authors
Hu, X., Yan, X., Gong, L., Wang, F., Xu, Y., Feng, L., Zhang, D., & Jiang, Y.
Venue
ACS Applied Materials & Interfaces
Published
2019-01-24
Volume
11
Issue
7
Pages
7379-7386
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2914040069
Cited by
169
References
1
FWCI
5.39
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Improved Piezoelectric Sensing Performance of P(VDF–TrFE) Nanofibers by Utilizing BTO Nanoparticles and Penetrated Electrodes. https://app.cochat.ai/papers/10.1021/acsami.8b19824
The paper
Hu, X., Yan, X., Gong, L., Wang, F., Xu, Y., Feng, L., Zhang, D., & Jiang, Y. (2019). Improved Piezoelectric Sensing Performance of P(VDF–TrFE) Nanofibers by Utilizing BTO Nanoparticles and Penetrated Electrodes. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.8b19824

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.