The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Hierarchically Structured Vertical Gold Nanowire Array-Based Wearable Pressure Sensors for Wireless Health Monitoring
Open accessAbstract
We have recently demonstrated that vertically aligned gold nanowires (v-AuNWs) are outstanding material candidates for wearable biomedical sensors toward real-time and noninvasive health monitoring because of their excellent tunable electrical conductivity, biocompatibility, chemical inertness, and wide electrochemical window. Here, we show that v-AuNWs could also be used to design a high-performance wearable pressure sensor when combined with rational structural engineering such as pyramid microarray-based hierarchical structures. The as-fabricated pressure sensor featured a low operation voltage of 0.1 V, high sensitivity in a low-pressure regime, a fast response time of <10 ms, and high durability with stable signals for the 10 000 cycling test. In conjunction with printed electrode arrays, we could generate a multiaxial map for spatial pressure detection. Furthermore, our flexible pressure sensor could be seamlessly connected with a Bluetooth low-energy module to detect high-quality artery pulses in a wireless manner. Our solution-based gold coating strategy offers the benefit of conformal coating of nanowires onto three-dimensional microstructured elastomeric substrates under ambient conditions, indicating promising applications in next-generation wearable biodiagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
An ultra-lightweight design for imperceptible plastic electronics
Kaltenbrunner, M., Sekitani, T., Reeder, J., Yokota, T., Kuribara, K., Tokuhara, T., Drack, M., Schwödiauer, R., Graz, I., Bauer-Gogonea, S., et al. (2013) · Nature · doi:10.1038/nature12314 · Cited by 2,485
A wearable and highly sensitive pressure sensor with ultrathin gold nanowires
Gong, S., Schwalb, W., Wang, Y., Chen, Y., Tang, Y., Si, J., Shirinzadeh, B., & Cheng, W. (2014) · Nature Communications · doi:10.1038/ncomms4132 · Cited by 2,064
Self-citationSchwartz, G., Tee, B. C.-K., Mei, J., Appleton, A. L., Kim, D. H., Wang, H., & Bao, Z. (2013) · Nature Communications · doi:10.1038/ncomms2832 · Cited by 2,042
Pan, L., Chortos, A., Yu, G., Wang, Y., Isaacson, S., Allen, R., Shi, Y., Dauskardt, R., & Bao, Z. (2014) · Nature Communications · doi:10.1038/ncomms4002 · Cited by 1,519
Self-citationA bioinspired flexible organic artificial afferent nerve
Kim, Y., Chortos, A., Xu, W., Liu, Y., Oh, J. Y., Son, D., Kang, J., Foudeh, A. M., Zhu, C., Lee, Y., et al. (2018) · Science · doi:10.1126/science.aao0098 · Cited by 1,466
Bio-Integrated Wearable Systems: A Comprehensive Review
Ray, T. R., Choi, J., Bandodkar, A. J., Krishnan, S., Gutruf, P., Tian, L., Ghaffari, R., & Rogers, J. A. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00573 · Cited by 1,350
Nanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
User-interactive electronic skin for instantaneous pressure visualization
Wang, C., Hwang, D., Yu, Z., Takei, K., Park, J., Chen, T., Ma, B., & Javey, A. (2013) · Nature Materials · doi:10.1038/nmat3711 · Cited by 1,182
Cited by
Chen, W., & Yan, X. (2020) · Journal of Materials Science & Technology · doi:10.1016/j.jmst.2019.11.010 · Cited by 481
Progress of flexible strain sensors for physiological signal monitoring
Shen, Z., Liu, F., Huang, S., Wang, H., Yang, C., Hang, T., Tao, J., Xia, W., & Xie, X. (2022) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2022.114298 · Cited by 250
Metadata
- Authors
- Zhu, B., Ling, Y., Yap, L. W., Yang, M., Lin, F., Gong, S., Wang, Y., An, T., Zhao, Y., & Cheng, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-07-19
- Volume
- 11
- Issue
- 32
- Pages
- 29014-29021
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2962952720
- Cited by
- 205
- References
- 19
- FWCI
- 8.87
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hierarchically Structured Vertical Gold Nanowire Array-Based Wearable Pressure Sensors for Wireless Health Monitoring. https://app.cochat.ai/papers/10.1021/acsami.9b06260
- The paper
- Zhu, B., Ling, Y., Yap, L. W., Yang, M., Lin, F., Gong, S., Wang, Y., An, T., Zhao, Y., & Cheng, W. (2019). Hierarchically Structured Vertical Gold Nanowire Array-Based Wearable Pressure Sensors for Wireless Health Monitoring. ACS Applied Materials & Interfaces. https://doi.org/10.1021/acsami.9b06260
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.