The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Highly Stretchable, Adhesive, and Mechanical Zwitterionic Nanocomposite Hydrogel Biomimetic Skin
Abstract
The artificial skin-like stretchable ionic sensor device usually requires a synergistic effect of reliable adhesion between human machine interface, reasonable mechanical strength, and visually displayable transparency. A plant-inspired zwitterionic hydrogel was prepared through rapid UV initiation in the existence of cellulose nanocrystals as physically crosslinker and reinforcing agent. The resulting transparent zwitterionic nanocomposite hydrogel successfully brings the synergistic advantages of robust adhesive strength between diversified substrates such as skins, plastics, glass, and steels with remarkable mechanical properties of a superior stretchability over 1000% strain, a mechanical tensile strength up to 0.61 MPa, and compressive strength up to 7.5 MPa, manifesting in superior ionic transport performance, simultaneously. Furthermore, the zwitterionic nanocomposite hydrogel was fabricated as a wearable compliant stretchable pressure-strain sensor in the modality of the skin-adhesive patch to be sensitive to human motion such as finger touch and speech recognition for personal healthcare of patient sensory rebuilding and physiological data acquisition. It maintains compressive cycling sensibility at diverse pressure during 0.5, 1.0, and 1.5 Hz, respectively. The multifunctional zwitterionic nanocomposite hydrogel could also be assembled into flexible electrical devices such as luminescent display and information transfer between human and robot communication for mechanosensory electronics and artificial intelligence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in engineering hydrogels
Zhang, Y. S., & Khademhosseini, A. (2017) · Science · doi:10.1126/science.aaf3627 · Cited by 2,908
Lab-on-Skin: A Review of Flexible and Stretchable Electronics for Wearable Health Monitoring
Liu, Y., Pharr, M., & Salvatore, G. A. (2017) · ACS Nano · doi:10.1021/acsnano.7b04898 · Cited by 1,725
Gan, D., Xing, W., Jiang, L., Fang, J., Zhao, C., Ren, F., Fang, L., Wang, K., & Lu, X. (2019) · Nature Communications · doi:10.1038/s41467-019-09351-2 · Cited by 1,029
Cai, G., Wang, J., Qian, K., Chen, J., Li, S., & Lee, P. S. (2017) · Advanced Science · doi:10.1002/advs.201600190 · Cited by 921
Cited by
Peng, W., Li, D., Dai, K., Wang, Y., Song, P., Li, H., Tang, P., Zhang, Z., Li, Z., Zhou, Y., et al. (2022) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2022.03.002 · Cited by 418
Cui, C., Fu, Q., Meng, L., Hao, S., Dai, R., & Yang, J. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c00807 · Cited by 353
Cutaneous Ionogel Mechanoreceptors for Soft Machines, Physiological Sensing, and Amputee Prostheses
Shen, Z., Zhu, X., Majidi, C., & Gu, G. (2021) · Advanced Materials · doi:10.1002/adma.202102069 · Cited by 291
He, Z., & Yuan, W. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c18405 · Cited by 283
Self-citationHao, S., Shao, C., Meng, L., Cui, C., Xu, F., & Yang, J. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c18250 · Cited by 258
Metadata
- Authors
- Yang, B., & Yuan, W.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-10-09
- Volume
- 11
- Issue
- 43
- Pages
- 40620-40628
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2980225589
- Cited by
- 189
- References
- 4
- FWCI
- 6.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.