Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 260

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Rapid-Response, Low Detection Limit, and High-Sensitivity Capacitive Flexible Tactile Sensor Based on Three-Dimensional Porous Dielectric Layer for Wearable Electronic Skin

Qiu, Jie, Guo, Xiaohui, Chu, Ran, Wang, Siliang, Zeng, Wei, Qu, Lei, Zhao, Yunong, Yan, Feng, Xing, Guozhong · 2019 · ACS Applied Materials & Interfaces

Abstract

Three-dimensional (3D) porous conductive composites explored in highly sensitive tactile sensors have attracted extensive close attention in recent years owing to their peculiar porous structure and unique physical properties in terms of excellent mechanical flexibility, high relative dielectric permittivity, and good elastic property. Herein, we report an practical, efficient, and macroscopic dip-coating process to manufacture rapid-response, low detection limit, high-sensitivity, and highly sensitive capacitive flexible tactile sensors. The fabrication process, tactile perception mechanism, and sensing performance of the developed devices are comparatively investigated. The homogeneous 3D hybrid network constructed by graphene nanoplatelets/carboxyl-functionalized multiwalled carbon nanotubes/silicone rubber composites anchored on polyurethane sponge skeletons exhibits a significantly improved dielectric property, resulting in a high-performance capacitive flexible tactile sensor with a fast response time (∼45 ms), an extremely low-pressure detection limit of ∼3 Pa, excellent sensitivity (∼0.062 kPa –1 ), and excellent durability and stability over 2000 cycles. Importantly, the flexible devices can be used as the wearable electronic skin and successfully mounted on human skin or a soft-bodied robot to achieve the capability of physiological stimuli monitoring, micropressure monitoring, soft grabbing, etc. Our rapid-response, low detection limit, and high-sensitivity capacitive flexible tactile sensor with a novel 3D porous dielectric layer could be a prospective candidate for the wearable applications in real-time and high-accuracy portable healthcare monitoring devices, advanced human–machine interfaces, and intelligent robot perception systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsami.9b16511

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 59 references

Cited by

Metadata

Authors
Qiu, J., Guo, X., Chu, R., Wang, S., Zeng, W., Qu, L., Zhao, Y., Yan, F., & Xing, G.
Venue
ACS Applied Materials & Interfaces
Published
2019-10-09
Volume
11
Issue
43
Pages
40716-40725
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2979870515
Cited by
260
References
59
FWCI
9.70
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.