The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Carbon Nanotubes/Hydrophobically Associated Hydrogels as Ultrastretchable, Highly Sensitive, Stable Strain, and Pressure Sensors
Abstract
Conductive hydrogels have become one of the most promising materials for skin-like sensors because of their excellent biocompatibility and mechanical flexibility. However, the limited stretchability, low toughness, and fatigue resistance lead to a narrow sensing region and insufficient durability of the hydrogel-based sensors. In this work, an extremely stretchable, highly tough, and anti-fatigue conductive nanocomposite hydrogel is prepared by integrating hydrophobic carbon nanotubes (CNTs) into hydrophobically associated polyacrylamide (HAPAAm) hydrogel. In this conductive hydrogel, amphiphilic sodium dodecyl sulfate was used to ensure uniform dispersion of CNTs in the hydrogel network, and hydrophobic interactions between the hydrogel matrix and the CNT surface formed, greatly improving the mechanical properties of the hydrogel. The obtained CNTs/HAPAAm hydrogel showed excellent stretchability (ca. 3000%), toughness (3.42 MJ m –3 ), and great anti-fatigue property. Moreover, it exhibits both high tensile strain sensitivity in the wide strain ranges (gauge factor = 4.32, up to 1000%) and high linear sensitivity (0.127 kPa –1 ) in a large-pressure region within 0–50 kPa. The CNTs/HAPAAm hydrogel-based sensors can sensitively and stably detect full-range human activities (e.g., elbow rotation, finger bending, swallowing motion, and pronouncing) and handwriting, demonstrating the CNTs/HAPAAm hydrogel’s potential as the wearable strain and pressure sensors for flexible devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Double‐Network Hydrogels with Extremely High Mechanical Strength
Gong, J. P., Katsuyama, Y., Kurokawa, T., & Osada, Y. (2003) · Advanced Materials · doi:10.1002/adma.200304907 · Cited by 4,542
Stretchable, Skin-Mountable, and Wearable Strain Sensors and Their Potential Applications: A Review
Amjadi, M., Kyung, K., Park, I., & Sitti, M. (2016) · Advanced Functional Materials · doi:10.1002/adfm.201504755 · Cited by 3,202
Skin-like pressure and strain sensors based on transparent elastic films of carbon nanotubes
Lipomi, D. J., Vosgueritchian, M., Tee, B. C.-K., Hellstrom, S. L., Lee, J. A., Fox, C. H., & Bao, Z. (2011) · Nature Nanotechnology · doi:10.1038/nnano.2011.184 · Cited by 3,188
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
Haraguchi, K., & Takehisa, T. (2002) · Advanced Materials · doi:10.1002/1521-4095(20020816)14:16<1120::aid-adma1120>3.0.co;2-9 · Cited by 2,108
Advances of flexible pressure sensors toward artificial intelligence and health care applications
Zang, Y., Zhang, F., Di, C.-A., & Zhu, D. (2015) · Materials Horizons · doi:10.1039/c4mh00147h · Cited by 1,272
Sun, J., Keplinger, C., Whitesides, G. M., & Suo, Z. (2014) · Advanced Materials · doi:10.1002/adma.201403441 · Cited by 1,198
Stretchable Conductive Polymers and Composites Based on PEDOT and PEDOT:PSS
Kayser, L. V., & Lipomi, D. J. (2019) · Advanced Materials · doi:10.1002/adma.201806133 · Cited by 1,186
Conductive Fiber‐Based Ultrasensitive Textile Pressure Sensor for Wearable Electronics
Lee, J., Kwon, H., Seo, J., Shin, S., Koo, J. H., Pang, C., Son, S., Kim, J. H., Jang, Y. H., Kim, D. E., et al. (2015) · Advanced Materials · doi:10.1002/adma.201500009 · Cited by 1,152
Lei, Z., Wang, Q., Sun, S., Zhu, W., & Wu, P. (2017) · Advanced Materials · doi:10.1002/adma.201700321 · Cited by 1,015
Cited by
Multifunctional conductive hydrogel-based flexible wearable sensors
Wang, L., Xu, T., & Zhang, X. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2020.116130 · Cited by 507
Nanocomposite hydrogel-based strain and pressure sensors: a review
Sun, X., Yao, F., & Li, J. (2020) · Journal of Materials Chemistry A · doi:10.1039/d0ta06965e · Cited by 420
Self-citationRecent progress of antibacterial hydrogels in wound dressings
Jia, B., Li, G., Cao, E., Luo, J., Zhao, X., & Huang, H. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100582 · Cited by 320
Sun, H., Zhao, Y., Jiao, S., Wang, C., Jia, Y., Dai, K., Zheng, G., Liu, C., Wan, P., & Shen, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202101696 · Cited by 317
Guo, Y., Wei, X., Gao, S., Yue, W., Li, Y., & Shen, G. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202104288 · Cited by 279
Constructions and Properties of Physically Cross-Linked Hydrogels Based on Natural Polymers
Yang, J., Chen, Y., Zhao, L., Zhang, J., & Luo, H. (2023) · Polymer Reviews · doi:10.1080/15583724.2022.2137525 · Cited by 261
Lu, Y., Yue, Y., Ding, Q., Mei, C., Xu, X., Wu, Q., Xiao, H., & Han, J. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.1c16828 · Cited by 254
Functionalized Hydrogel-Based Wearable Gas and Humidity Sensors.
Luo, Y., Li, J., Ding, Q., Wang, H., Liu, C., & Wu, J. (2023) · Nano-Micro Letters · doi:10.1007/s40820-023-01109-2 · Cited by 236
Self-citation
Metadata
- Authors
- Qin, Z., Sun, X., Yu, Q., Zhang, H., Wu, X., Yao, M., Liu, W., Yao, F., & Li, J.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-01-08
- Volume
- 12
- Issue
- 4
- Pages
- 4944-4953
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2999416894
- Cited by
- 384
- References
- 53
- FWCI
- 16.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.