Intestine-on-a-Chip Microfluidic Model for Efficient in Vitro Screening of Oral Chemotherapeutic Uptake
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Many highly effective chemotherapeutic agents can only be administered intravenously as their oral delivery is compromised by low gastro-intestinal solubility and permeability. SN-38 (7-ethyl-10-hydroxycamptothecin) is one such drug; however, recently synthesized lipophilic prodrugs offer a potential solution to the low oral bioavailability issue. Here we introduce a microfluidic-based intestine-on-a-chip (IOAC) model, which has the potential to provide new insight into the structure-permeability relationship for lipophilic prodrugs. More specifically, the IOAC model utilizes external mechanical cues that induce specific differentiation of an epithelial cell monolayer to provide a barrier function that exhibits an undulating morphology with microvilli expression on the cell surface; this is more biologically relevant than conventional Caco-2 Transwell models. IOAC permeability data for SN38 modified with fatty acid esters of different chain lengths and at different molecular positions correlate excellently with water-lipid partitioning data and have the potential to significantly advance their preclinical development. In addition to advancing mechanistic insight into the permeability of many challenging drug candidates, we envisage the IOAC model to also be applicable to nanoparticle and biological entities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amidon, G. L., Lennernäs, H., Shah, V. P., & Crison, J. R. (1995) · Pharmaceutical Research · doi:10.1023/a:1016212804288 · Cited by 5,430
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Lentle, R. G., & Janssen, P. W. M. (2008) · Journal of Comparative Physiology B · doi:10.1007/s00360-008-0264-x · Cited by 213
A microfluidic system to evaluate intestinal absorption
Imura, Y., Asano, Y., Sato, K., & Yoshimura, E. (2009) · Analytical Sciences · doi:10.2116/analsci.25.1403 · Cited by 159
TANNERGREN, C. (2004) · Clinical Pharmacology & Therapeutics · doi:10.1016/j.clpt.2003.12.012 · Cited by 138
Wang, Y., Lee, D., Zhang, L., Jeon, H., Mendoza-Elias, J. E., Harvat, T. A., Hassan, S. Z., Zhou, A., Eddington, D. T., & Oberholzer, J. (2012) · Biomedical Microdevices · doi:10.1007/s10544-011-9618-3 · Cited by 63
Cited by
Microfluidic Organ-on-a-Chip Models of Human Intestine
Bein, A., Shin, W., Jalili-Firoozinezhad, S., Park, M. H., Sontheimer-Phelps, A., Tovaglieri, A., Chalkiadaki, A., Kim, H. J., & Ingber, D. E. (2018) · Cellular and Molecular Gastroenterology and Hepatology · doi:10.1016/j.jcmgh.2017.12.010 · Cited by 625
Delon, L. C., Guo, Z., Oszmiana, A., Chien, C.-C., Gibson, R., Prestidge, C., & Thierry, B. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.119521 · Cited by 171
Self-citationBone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142
Fois, C. A. M., Schindeler, A., Valtchev, P., & Dehghani, F. (2021) · Biomedical Microdevices · doi:10.1007/s10544-021-00591-y · Cited by 82
Mechanisms of uptake and transport of particulate formulations in the small intestine
Delon, L., Gibson, R. J., Prestidge, C. A., & Thierry, B. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.02.006 · Cited by 64
Self-citation
Metadata
- Authors
- Pocock, K., Delon, L., Bala, V., Rao, S., Priest, C., Prestidge, C., & Thierry, B.
- Venue
- ACS Biomaterials Science & Engineering
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-05-30
- Volume
- 3
- Issue
- 6
- Pages
- 951-959
- ISSN
- 2373-9878 (ISSN-L)
- OpenAlex
- W2614912517
- Cited by
- 111
- References
- 7
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.