CoChat

Biowire Model of Interstitial and Focal Cardiac Fibrosis

Open access
Wang, Erika Yan, Rafatian, Naimeh, Zhao, Yimu, Lee, Angela, Lai, Benjamin Fook Lun, Lu, Rick Xingze, Jekic, Danica, Davenport Huyer, Locke, Knee-Walden, Ericka J., Bhattacharya, Shoumo, Backx, Peter H., Radisic, Milica · 2019 · ACS Central Science
Cited by 127

The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.

Abstract

High Resolution Image Download MS PowerPoint Slide Myocardial fibrosis is a severe global health problem due to its prevalence in all forms of cardiac diseases and direct role in causing heart failure. The discovery of efficient antifibrotic compounds has been hampered due to the lack of a physiologically relevant disease model. Herein, we present a disease model of human myocardial fibrosis and use it to establish a compound screening system. In the Biowire II platform, cardiac tissues are suspended between a pair of poly(octamethylene maleate (anhydride) citrate) (POMaC) wires. Noninvasive functional readouts are realized on the basis of the deflection of the intrinsically fluorescent polymer. The disease model is constructed to recapitulate contractile, biomechanical, and electrophysiological complexities of fibrotic myocardium. Additionally, we constructed a heteropolar integrated model with fibrotic and healthy cardiac tissues coupled together. The integrated model captures the regional heterogeneity of scar lesion, border zone, and adjacent healthy myocardium. Finally, we demonstrate the utility of the system for the evaluation of antifibrotic compounds. The high-fidelity in vitro model system combined with convenient functional readouts could potentially facilitate the development of precision medicine strategies for cardiac fibrosis modeling and establish a pipeline for preclinical compound screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acscentsci.9b00052

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 17 references

Cited by

See all 127

Metadata

Authors
Wang, E. Y., Rafatian, N., Zhao, Y., Lee, A., Lai, B. F. L., Lu, R. X., Jekic, D., Davenport Huyer, L., Knee-Walden, E. J., Bhattacharya, S., Backx, P. H., & Radisic, M.
Venue
ACS Central Science
Published
2019-06-04
Volume
5
Issue
7
Pages
1146-1158
ISSN
  • 2374-7943 (ISSN-L)
  • 2374-7951
OpenAlex
W2948856608
Cited by
127
References
17
FWCI
11.45
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Biowire Model of Interstitial and Focal Cardiac Fibrosis. https://app.cochat.ai/papers/10.1021/acscentsci.9b00052
The paper
Wang, E. Y., Rafatian, N., Zhao, Y., Lee, A., Lai, B. F. L., Lu, R. X., Jekic, D., Davenport Huyer, L., Knee-Walden, E. J., Bhattacharya, S., Backx, P. H., & Radisic, M. (2019). Biowire Model of Interstitial and Focal Cardiac Fibrosis. ACS Central Science. https://doi.org/10.1021/acscentsci.9b00052

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.