Response to Letters to the Editor on Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks: Revised and Expanded Results
Open accessThe DOI matches its Crossref record; 21 of the 22 references it cites were found in a registry or an index.
Abstract
ADVERTISEMENT RETURN TO ISSUEPREVLetter to the EditorNEXTResponse to Letters to the Editor on Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks: Revised and Expanded ResultsAbhiteja KondaAbhiteja KondaCenter for Nanoscale Materials, Argonne National Laboratory Lemont, Illinois 60439, United StatesMore by Abhiteja Kondahttp://orcid.org/0000-0003-3362-0583, Abhinav PrakashAbhinav PrakashCenter for Nanoscale Materials, Argonne National Laboratory Lemont, Illinois 60439, United StatesPritzker School of Molecular Engineering, University of Chicago, Chicago, Illinois 60637, United StatesMore by Abhinav Prakashhttp://orcid.org/0000-0002-8899-0568, Gregory A. MossGregory A. MossWorker Safety & Health Division, Argonne National Laboratory Lemont, Illinois 60439, United StatesMore by Gregory A. Moss, Michael SchmoldtMichael SchmoldtCenter for Nanoscale Materials, Argonne National Laboratory Lemont, Illinois 60439, United StatesWorker Safety & Health Division, Argonne National Laboratory Lemont, Illinois 60439, United StatesMore by Michael Schmoldt, Gregory D. GrantGregory D. GrantPritzker School of Molecular Engineering, University of Chicago, Chicago, Illinois 60637, United StatesMore by Gregory D. Grant, and Supratik Guha*Supratik GuhaCenter for Nanoscale Materials, Argonne National Laboratory Lemont, Illinois 60439, United StatesPritzker School of Molecular Engineering, University of Chicago, Chicago, Illinois 60637, United States*Telephone: 773-834-4209. Email: [email protected]More by Supratik Guhahttp://orcid.org/0000-0001-5071-8318Cite this: ACS Nano 2020, 14, 9, 10764–10770Publication Date (Web):September 22, 2020Publication History Received12 June 2020Published online22 September 2020Published inissue 22 September 2020https://pubs.acs.org/doi/10.1021/acsnano.0c04897https://doi.org/10.1021/acsnano.0c04897letterACS PublicationsCopyright © 2020 American Chemical Society. This publication is available under these Terms of Use. Request reuse permissions This publication is free to access through this site. Learn MoreArticle Views5651Altmetric-Citations22LEARN ABOUT THESE METRICSArticle Views are the COUNTER-compliant sum of full text article downloads since November 2008 (both PDF and HTML) across all institutions and individuals. These metrics are regularly updated to reflect usage leading up to the last few days.Citations are the number of other articles citing this article, calculated by Crossref and updated daily. Find more information about Crossref citation counts.The Altmetric Attention Score is a quantitative measure of the attention that a research article has received online. Clicking on the donut icon will load a page at altmetric.com with additional details about the score and the social media presence for the given article. Find more information on the Altmetric Attention Score and how the score is calculated. Share Add toView InAdd Full Text with ReferenceAdd Description ExportRISCitationCitation and abstractCitation and referencesMore Options Share onFacebookTwitterWechatLinked InRedditEmail PDF (2 MB) Get e-AlertscloseSupporting Info (1)»Supporting Information Supporting Information SUBJECTS:Atmospheric chemistry,Filtration,Layers,Particle size,Plants Get e-Alerts
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Substantial variation exists within each of these general classes, however. For example, substantial fit and performance discrepancies have been demonstrated for KN95 vs. N95 respirators, or different designs of cloth coverings [11,12,13,14].”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [11]
In the citing paper
“The data sets employed by Wagner et al. represent a range of mask fit conditions including human subjects, mannikins, and non-leaking custom apparatus [11,20,21,22], but all are likely a best case compared to the range of actual public practice because they were laboratory tested with due diligence and proper usage.”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [11]
In the citing paper
“The higher mask efficiencies predicted for larger allergens compared to sub-micrometer smoke and breathing-generated particles is consistent with numerous, particle size-dependent laboratory mask studies (e.g., [11,20,21,22]).”
From Comparative Mask Protection against Inhaling Wildfire Smoke, Allergenic Bioaerosols, and Infectious Particles (2022) · cites this paper as [11]
Citations
Cites
A novel coronavirus from patients with pneumonia in China, 2019
Zhu, N., Zhang, D., Wang, W., Li, X., Yang, B., Song, J., Zhao, X., Huang, B., Shi, W., Lu, R., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2001017 · Cited by 28,244
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872
Aerosol filtration efficiency of common fabrics used in respiratory cloth masks
Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020) · ACS Nano · doi:10.1021/acsnano.0c03252 · Cited by 934
Self-citationGrinshpun, S. A., Haruta, H., Eninger, R. M., Reponen, T., McKay, R. T., & Lee, S.-A. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903120086 · Cited by 353
Physico-chemical characteristics of evaporating respiratory fluid droplets
Vejerano, E. P., & Marr, L. C. (2018) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0939 · Cited by 314
On the Minimum Efficiency and the Most Penetrating Particle Size for Fibrous Filters
Lee, K. W., & Liu, B. Y. H. (1980) · Journal of the Air Pollution Control Association · doi:10.1080/00022470.1980.10464592 · Cited by 267
COVID-19: A Call for Physical Scientists and Engineers
Huang, H., Fan, C., Li, M., Nie, H.-L., Wang, F.-B., Wang, H., Wang, R., Xia, J., Zheng, X., Zuo, X., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02618 · Cited by 217
Fundamental protective mechanisms of face masks against droplet infections
Kähler, C. J., & Hain, R. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105617 · Cited by 191
Lai, A. C. K., Poon, C. K. M., & Cheung, A. C. T. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0537 · Cited by 155
Research works printed but not linked: 2
- Perić, R.; Perić, M., Analytical and numerical investigation of the airflow in face masks used for protection against COVID-19 virus-implications for mask design and usage. arXiv preprint arXiv:2005.08800 2020. Note that for the calculations, we used a single slit gap with height 2 mm, width 36 mm (4 slits of 9 mm width), and length 1 mm. · arXiv
- Viola, I. M.; Peterson, B.; Pisetta, G.; Pavar, G.; Akhtar, H.; Menoloascina, F.; Mangano, E.; Dunn, K. E.; Gabl, R.; Nila, A., Face Coverings, Aerosol Dispersion and Mitigation of Virus Transmission Risk. arXiv (Medical Physics), May 11, 2020, 2005.10720, ver. 1.
Cited by
A guideline to limit indoor airborne transmission of COVID-19
Bazant, M. Z., & Bush, J. W. M. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2018995118 · Cited by 477
Inward and Outward Effectiveness of Cloth Masks, a Surgical Mask, and a Face Shield
Pan, J., Harb, C., Leng, W., & Marr, L. C. (2021) · Aerosol Science and Technology · doi:10.1080/02786826.2021.1890687 · Cited by 186
Duncan, S., Bodurtha, P., & Naqvi, S. (2021) · PLOS ONE · doi:10.1371/journal.pone.0258191 · Cited by 75
Monitoring carbon dioxide to quantify the risk of indoor airborne transmission of COVID-19
Bazant, M. Z., Kodio, O., Cohen, A. E., Khan, K., Gu, Z., & Bush, J. W. M. (2021) · Flow · doi:10.1017/flo.2021.10 · Cited by 83
Expiratory aerosol particle escape from surgical masks due to imperfect sealing
Cappa, C. D., Asadi, S., Barreda, S., Wexler, A. S., Bouvier, N. M., & Ristenpart, W. D. (2021) · Scientific Reports · doi:10.1038/s41598-021-91487-7 · Cited by 67
Metadata
- Authors
- Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S.
- Affiliations
- Argonne National Laboratory (US)
- University of Chicago (US)
- Corresponding author
- Guha, Supratik
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-09-22
- Volume
- 14
- Issue
- 9
- Pages
- 10764-10770
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3087558528
- Cited by
- 30
- References
- 22
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 7 · 2021: 17 · 2020: 1
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Funders
- U.S. Department of Defense
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Physical Sciences › Materials Science › Polymers and Plastics › Textile materials and evaluations
- Keywords
- cloth masks, respirators, aerosol filtration efficiency, fabric filtration, N95 respirators, face masks, COVID-19 personal protective equipment, polyesters, polypropylene, polytetrafluoroethylene, polyacrylonitrile, polyurethane, polyvinyl chloride, polyethylene terephthalate
- MeSH terms
- Aerosols, Filtration, Masks, Textiles
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Response to Letters to the Editor on Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks: Revised and Expanded Results. https://app.cochat.ai/papers/10.1021/acsnano.0c04897
- The paper
- Konda, A., Prakash, A., Moss, G. A., Schmoldt, M., Grant, G. D., & Guha, S. (2020). Response to Letters to the Editor on Aerosol Filtration Efficiency of Common Fabrics Used in Respiratory Cloth Masks: Revised and Expanded Results. ACS Nano. https://doi.org/10.1021/acsnano.0c04897
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.