Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This article reports on a noninvasive approach in detecting and following-up individuals who are at-risk or have an existing COVID-19 infection, with a potential ability to serve as an epidemic control tool. The proposed method uses a developed breath device composed of a nanomaterial-based hybrid sensor array with multiplexed detection capabilities that can detect disease-specific biomarkers from exhaled breath, thus enabling rapid and accurate diagnosis. An exploratory clinical study with this approach was examined in Wuhan, China, during March 2020. The study cohort included 49 confirmed COVID-19 patients, 58 healthy controls, and 33 non-COVID lung infection controls. When applicable, positive COVID-19 patients were sampled twice: during the active disease and after recovery. Discriminant analysis of the obtained signals from the nanomaterial-based sensors achieved very good test discriminations between the different groups. The training and test set data exhibited respectively 94% and 76% accuracy in differentiating patients from controls as well as 90% and 95% accuracy in differentiating between patients with COVID-19 and patients with other lung infections. While further validation studies are needed, the results may serve as a base for technology that would lead to a reduction in the number of unneeded confirmatory tests and lower the burden on hospitals, while allowing individuals a screening solution that can be performed in PoC facilities. The proposed method can be considered as a platform that could be applied for any other disease infection with proper modifications to the artificial intelligence and would therefore be available to serve as a diagnostic tool in case of a new disease outbreak.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For both of these examples, interface problems mainly arise in heterogeneous integration of different materials, such as for material bonding and embedding, which can be addressed by micromechanics, chemical bonding links, etc.[609]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [609]
Citations
Cites
Clinical characteristics of coronavirus disease 2019 in China
Guan, W.-J., Ni, Z.-Y., Hu, Y., Liang, W.-H., Ou, C.-Q., He, J.-X., Liu, L., Shan, H., Lei, C.-L., Hui, D. S. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2002032 · Cited by 30,246
Self-citationChen, N., Zhou, M., Dong, X., Qu, J., Gong, F., Han, Y., Qiu, Y., Wang, J., Liu, Y., Wei, Y., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30211-7 · Cited by 21,415
Self-citationSensitivity of Chest CT for COVID-19: Comparison to RT-PCR
Fang, Y., Zhang, H., Xie, J., Lin, M., Ying, L., Pang, P., & Ji, W. (2020) · Radiology · doi:10.1148/radiol.2020200432 · Cited by 3,354
Wynants, L., Van Calster, B., Bonten, M. M., Collins, G. S., Debray, T. P., De Vos, M., Haller, M. C., Heinze, G., Moons, K. G., Riley, R. D., et al. (2020) · doi:10.1101/2020.03.24.20041020 · Cited by 3,070
Covid-19 in Critically Ill Patients in the Seattle Region — Case Series
Bhatraju, P. K., Ghassemieh, B. J., Nichols, M., Kim, R., Jerome, K. R., Nalla, A. K., Greninger, A. L., Pipavath, S., Wurfel, M. M., Evans, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004500 · Cited by 2,583
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Self-citationInterpreting a covid-19 test result
Watson, J., Whiting, P. F., & Brush, J. E. (2020) · BMJ · doi:10.1136/bmj.m1808 · Cited by 712
Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citation
Research works printed but not linked: 2
- Watson J., 2020, BMJ., 369
- 10.1136/bmj.m1328 · doi:10.1136/bmj.m1328 · Paper page
Cited by
Items 301–380 of 380
Volatile Organic Compound Exhaled Breath Sensing
de León-Martínez, L. D., Glöckler, J., Mizaikoff, B., Flores‐Ramírez, R., & Díaz‐Barriga, F. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00154-0 · Cited by 2
Engineering Volatile Biomarkers for Disease Detection
Broza, Y. Y. (2022) · Royal Society of Chemistry eBooks · doi:10.1039/9781839166990-00232 · Cited by 1
Self-citationSingh, A., Hassen, W., St‐Onge, R., & Dubowski, J. J. (2023) · The Journal of Physical Chemistry C · doi:10.1021/acs.jpcc.3c05200 · Cited by 2
Flexible and Wearable Volatile Organic Compounds (VOCs) Sensing: Development and Future Perspectives
Ren, H. (2024) · European journal of applied sciences · doi:10.14738/aivp.121.16358 · Cited by 1
Jin, W., Zhang, L., Jia, S., Xiao, H., Wang, X., Peng, H. W., Lu, X., Zhang, Y., Yang, G., Shen, F., et al. (2025) · Analytical Chemistry · doi:10.1021/acs.analchem.5c04095 · Cited by 1
Self-citationPatterning technologies in bioanalysis: From sensing surface construction to detection applications
Liu, M., Sun, Z., Zhang, Y., 葛慎光, Huang, H., Han, L., Liu, X., Zhou, W., & Liu, H. (2025) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2025.101172 · Cited by 2
Self-citationChaudhary, V., Sable, H., & Khosla, A. (2026) · Comput. Biol. Medicine · doi:10.1016/j.compbiomed.2026.111846 · Cited by 1
Nanotube- and nanowire-based sensors for air quality monitoring
Rani, S., & Roy, S. C. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-88449-5.00014-0 · Cited by 1
The IOMT-Based Risk-Free Approach to Lung Disorders Detection from Exhaled Breath Examination
Ghani, M., & Gilanie, G. (2023) · Intelligent Automation & Soft Computing · doi:10.32604/iasc.2023.034857 · Cited by 1
Ricco, A. J., Hannon, A., & Li, J. (2025) · Frontiers in Sensors · doi:10.3389/fsens.2025.1575769 · Cited by 1
Susanto, A. D., Agustin, H., Taufik, M., Rahman, M. A., & Hidayat, M. (2022) · Archives of Clinical Infectious Diseases · doi:10.5812/archcid-119263 · Cited by 1
Breath of Health: spectroscopy-based breath test for the detection of SARS-CoV-2
Padawer, D., Qadan, A., Karameh, M., Darawshy, F., Laor, A., Banker, S., & Fridlender, Z. G. (2024) · Scandinavian Journal of Infectious Diseases · doi:10.1080/23744235.2024.2313020 · Cited by 1
Chemical Sensor for the Diagnosis of Coronavirus
Rao, G. K., Sengar, A. K., & Pathak, S. R. (2021) · Wiley eBooks · doi:10.1002/9783527832521.ch8 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv-2021-l393t-v35 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v30 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v6 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v15 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv-2021-l393t-v33 · Cited by 1
A Novel Magnetic Respiratory Sensor for Human Healthcare
Hwang, K. Y., Jimenez, V. O., Muchharla, B., Eggers, T., Le, A., Lãm, V. Đ., & Phan, M. (2021) · Applied Sciences · doi:10.3390/app11083585
“This suggests that older people tend to relax more during sleep [31].”
BackgroundInfluentialWITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v32 · Cited by 1
Datta, S. (2021) · doi:10.33774/chemrxiv-2021-l393t-v35
Ishii, A., Sugiyama, M., Ohta, M., Sumida, Y., Kimura, Y., Tsutsumi, N., Yamashita, Y. I., Saeki, H., Uchiyama, H., Kawanaka, H., et al. (2013) · PubMed
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v31
Datta, S. (2021) · doi:10.33774/chemrxiv-2021-l393t-v33 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v19
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v10
Datta, S. (2021) · doi:10.33774/chemrxiv-2021-l393t-v36 · Cited by 1
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v3
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v20
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v2
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v5
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v7
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v9
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v25
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v26
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v28
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v14
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v13
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v24
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v18
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v17
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v8
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v4
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v29
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv-2021-l393t-v34
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v22
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v27
WITHDRAWNPreprint
Datta, S. (2021) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v23
Datta, S. (2021) · doi:10.33774/chemrxiv-2021-l393t-v34
WITHDRAWNPreprint
Datta, S. (2020) · ChemRxiv · doi:10.26434/chemrxiv.13102877.v12
Role of nanotechnology for coronavirus detection
Mall, A., Das, T. R., Bhattacharjee, P., Pal, S., Sharma, S., Shukla, S. K., & Patra, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90280-9.00005-5
Progress of hollow materials in diagnosis of COVID-19
Hussain, A., Shabbir, S., Faizan, M., & Tajwar, M. A. (2022) · Chemical Reports · doi:10.25082/cr.2022.01.002
Nanomaterial-based Sensors for Volatile Biomarkers
Haick, H. (2022) · Royal Society of Chemistry eBooks · doi:10.1039/9781839166990-00379
Self-citationLekshmi, M. K., & Nair, R. S. (2022) · International Research Journal of Ayurveda & Yoga · doi:10.47223/irjay.2022.51212
Progress of Hollow Materials in Diagnosis of Covid-19
Hussain, A., Shabbir, S., & Faizan, M. (2022) · Austin Journal of Pharmacology and Therapeutics · doi:10.26420/austinjpharmacolther.2022.1163
Gifta, G., I.V, B. K. J., Franklin, S. A., Rani, D. G. N., & Nirmal, D. (2023) · ECS Journal of Solid State Science and Technology · doi:10.1149/2162-8777/acd6b7
Diagnostic Techniques for Corona Virus
Akram, M., Laila, U., Khalil, M. T., Anwar, H., Zainab, R., Shahid, N., & Hamouda, I. M. (2023) · Journal of BioMed Research and Reports · doi:10.59657/2837-4681.brs.23.009
µbreath for early diseases detection: Achievement and challenge
Wardoyo, A. Y. P. (2023) · AIP conference proceedings · doi:10.1063/5.0166928
Novel microdevices to analyze toxic volatile organic compounds.
Halder, S. (2023) · ThinkIR: The University of Louisville's Institutional Repository (University of Louisville) · doi:10.18297/etd/4083
Assessment of COVID-19 from Features Extraction of Exhaled Breath Using Signal Processing MethodsPreprint
Malarvili, M. B., Ramanathan, S., Manikam, R., Ramli, A. A., Ruslay, R. U. R., Kamarudin, A., & Tarmizi, A. A. A. (2024) · Qeios · doi:10.32388/66llgg
The Effectiveness of Armpit Sweat Odor with COVID-19 Detection Device for Detecting COVID-19
Parimba, I. S., Bakhtiar, A., Soedarsono, S., & Sarn, R. (2024) · Pharmacognosy Journal · doi:10.5530/pj.2024.16.116
Coronavirus Anatomy and Its Analytical Approaches for Targeting COVID-19
Ramanathan, S., Malarvili, M. B., Gopinath, S. C. B., & Nindhia, T. G. T. (2024) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-61939-7_2
A clinical study to detect COVID-19 infection from a non-invasive breath sample
Winchester, S., Rowles, J., Pomeroy, L., Chapovsky, A., Gorbunov, B. Z., John, J., Jabbar, K., & John, I. (2024) · RPS Pharmacy and Pharmacology Reports · doi:10.1093/rpsppr/rqae026
Poddar, A., & Rao, S. R. (2025) · 3 Biotech · doi:10.1007/s13205-025-04342-1
“In another study, a portable handheld analyzer with eight different sensors was developed by Shan et al. (2020).”
Gold Nanoparticle-Based Breath Test Device for Rapid Detection of Infections
Becke, S., Geus, P. F., Bondzio, G., Schroer, J., Froese, V., Dernedde, J., Kertzscher, U., Bierewirtz, T., & Lommel, M. (2024) · IEEE-EMBS Conference on Biomedical Engineering and Sciences · doi:10.1109/iecbes61011.2024.10990865
“[ 16-18] Colorimetric biosensors based on metal nanoparticles are being proposed as a more sensitive alternative for use in molecular diagnostics [19], [20].”
Electronic noses in exhaled breath analysis
Grochala, D., Paleczek, A., & Rydosz, A. M. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33796-3.00002-7
Nanotechnology for diagnosis of COVID-19: Current achievements and future directions
Zhu, Y., Tse, C., Lei, C., & Xu, C. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33002-5.00008-7
Sundararaman, G., & Vijayakumar, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-33002-5.00005-1
Shin, W., Itoh, T., Masuda, Y., Kitawaki, T., & Sawano, M. (2025) · Chemosensors · doi:10.3390/chemosensors14010001
“A few studies have applied this method to disease screening [13,14].”
Voit, F., Erber, J., Feuerherd, M., Fries, H., Bitterlich, N., Diehl-Wiesenecker, E., Gladis, S., Lieb, J., Protzer, U., Schneider, J., et al. (2024) · Figshare · doi:10.6084/m9.figshare.26614513
Shakya, H., & Gandhi, S. (2025) · De Gruyter eBooks · doi:10.1515/9783111681870-012
Li, W., Lv, M., Cheng, M., Han, Y., Yu, H., Huang, Y., Meng, D., Xu, X., Sun, L., Lu, Z., et al. (2026) · Journal of Breath Research · doi:10.1088/1752-7163/ae5a51
Self-citationResearch Progress of Wearable Electrochemical Biosensors for Personalized Medicine
Guan, F. (2026) · Innovative Journal of Applied Science · doi:10.70844/ijas.2026.3.46
Fu, R., Zhang, X. Z., Ni, Q., Qin, Y., Wu, Z., Nie, S., Xu, H. J., & Mo, F. (2026) · BMC Pulmonary Medicine · doi:10.1186/s12890-026-04269-0
“Future research must include a broader range of disease control groups to strictly validate the specificity of these biomarkers and rule out the possibility that they are merely markers of general inflammatory responses [38].”
Shen, Y., Yuan, W., Li, L., Zheng, Y., Liu, K., Li, H., Li, H., ZHAO, Y., Ying, B., Guo, L., et al. (2026) · Advanced Science · doi:10.1002/advs.76244
Self-citationHetta, H. F., Ahmed, R., Haseeb, A., Bukhari, S. Q., Alatawi, Z., Mahrous, A. J., Elrggal, M. E., Masri, M. A., & Kotb, A. A. (2026) · Diagnostics · doi:10.3390/diagnostics16152402
“Although promising for rapid screening, environmental and physiological confounders remain challenges for real-world deployment [124].”
Sensors in Digital Health Solutions Empowered by Artificial Intelligence Capabilities
Hetemi, D., Pinson, J., Noël, V., Shkirskiy, V., & Hoti, K. (2026) · IEEE Sensors Reviews · doi:10.1109/sr.2026.3722596
“Sensors used in off-body detection are dedicated to the analysis of extracted body fluids and gas or images [107], [115], [116], [117], [118].”
Nanostructure-integrated electrochemical devices for biomedical applications
Qayoom, F., Khurshid, S., Rather, J. A., Andrabi, S. J. A., Bhasker, R., Baba, S. A., & Kannan, P. (2026) · Nano Trends · doi:10.1016/j.nwnano.2026.100247
Metadata
- Authors
- Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., Liu, W., Zhou, S., Jin, W., Zhang, Q., Hu, D., Lin, L., Zhang, Q., Li, W., Wang, J., Liu, H., Pan, Y., & Haick, H.
- Affiliations
- University of Science and Technology of China (CN)
- Technion – Israel Institute of Technology (IL)
- First Affiliated Hospital of Anhui Medical University (CN)
- Department of Respiratory Disease, Anhui Provincial Chest Hospital, 230000, Hefei, Anhui Province, People’s Republic of China
- Corresponding author
- Liu, Hu
- Pan, Yueyin
- Haick, Hossam
- ORCID
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-18
- Volume
- 14
- Issue
- 9
- Pages
- 12125-12132
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3049021859
- Cited by
- 384
- References
- 26
- Citations by year
- 2026: 10 · 2025: 33 · 2024: 51 · 2023: 54 · 2022: 90 · 2021: 115 · 2020: 30
- FWCI
- 22.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Technion-Israel Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- COVID-19 detection, breath analysis, multiplexed sensing, non-invasive diagnosis, disease-specific biomarkers, point-of-care screening, epidemic control, SARS-CoV-2
- MeSH terms
- Data Accuracy, Betacoronavirus, COVID-19, SARS-CoV-2, Breath Tests, China, Female, Humans, Male, Middle Aged, Pneumonia, Viral, Respiratory System, Sensitivity and Specificity, Biomarkers, Coronavirus Infections, Asian People, Nanostructures, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.