Multiplexed Nanomaterial-Based Sensor Array for Detection of COVID-19 in Exhaled Breath
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
This article reports on a noninvasive approach in detecting and following-up individuals who are at-risk or have an existing COVID-19 infection, with a potential ability to serve as an epidemic control tool. The proposed method uses a developed breath device composed of a nanomaterial-based hybrid sensor array with multiplexed detection capabilities that can detect disease-specific biomarkers from exhaled breath, thus enabling rapid and accurate diagnosis. An exploratory clinical study with this approach was examined in Wuhan, China, during March 2020. The study cohort included 49 confirmed COVID-19 patients, 58 healthy controls, and 33 non-COVID lung infection controls. When applicable, positive COVID-19 patients were sampled twice: during the active disease and after recovery. Discriminant analysis of the obtained signals from the nanomaterial-based sensors achieved very good test discriminations between the different groups. The training and test set data exhibited respectively 94% and 76% accuracy in differentiating patients from controls as well as 90% and 95% accuracy in differentiating between patients with COVID-19 and patients with other lung infections. While further validation studies are needed, the results may serve as a base for technology that would lead to a reduction in the number of unneeded confirmatory tests and lower the burden on hospitals, while allowing individuals a screening solution that can be performed in PoC facilities. The proposed method can be considered as a platform that could be applied for any other disease infection with proper modifications to the artificial intelligence and would therefore be available to serve as a diagnostic tool in case of a new disease outbreak.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“For both of these examples, interface problems mainly arise in heterogeneous integration of different materials, such as for material bonding and embedding, which can be addressed by micromechanics, chemical bonding links, etc.[609]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [609]
Citations
Cites
Clinical characteristics of coronavirus disease 2019 in China
Guan, W.-J., Ni, Z.-Y., Hu, Y., Liang, W.-H., Ou, C.-Q., He, J.-X., Liu, L., Shan, H., Lei, C.-L., Hui, D. S. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2002032 · Cited by 30,246
Self-citationChen, N., Zhou, M., Dong, X., Qu, J., Gong, F., Han, Y., Qiu, Y., Wang, J., Liu, Y., Wei, Y., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30211-7 · Cited by 21,415
Self-citationSensitivity of Chest CT for COVID-19: Comparison to RT-PCR
Fang, Y., Zhang, H., Xie, J., Lin, M., Ying, L., Pang, P., & Ji, W. (2020) · Radiology · doi:10.1148/radiol.2020200432 · Cited by 3,354
Wynants, L., Van Calster, B., Bonten, M. M., Collins, G. S., Debray, T. P., De Vos, M., Haller, M. C., Heinze, G., Moons, K. G., Riley, R. D., et al. (2020) · doi:10.1101/2020.03.24.20041020 · Cited by 3,070
Covid-19 in Critically Ill Patients in the Seattle Region — Case Series
Bhatraju, P. K., Ghassemieh, B. J., Nichols, M., Kim, R., Jerome, K. R., Nalla, A. K., Greninger, A. L., Pipavath, S., Wurfel, M. M., Evans, L., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2004500 · Cited by 2,583
Seo, G., Lee, G., Kim, M. J., Baek, S.-H., Choi, M., Ku, K. B., Lee, C.-S., Jun, S., Park, D., Kim, H. G., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c02823 · Cited by 1,837
Diagnosing COVID-19: The Disease and Tools for Detection
Udugama, B., Kadhiresan, P., Kozlowski, H. N., Malekjahani, A., Osborne, M., Li, V. Y. C., Chen, H., Mubareka, S., Gubbay, J. B., & Chan, W. C. W. (2020) · ACS Nano · doi:10.1021/acsnano.0c02624 · Cited by 1,754
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Self-citationInterpreting a covid-19 test result
Watson, J., Whiting, P. F., & Brush, J. E. (2020) · BMJ · doi:10.1136/bmj.m1808 · Cited by 712
Nakhleh, M. K., Amal, H., Jeries, R., Broza, Y. Y., Aboud, M., Gharra, A., Ivgi, H., Khatib, S., Badarneh, S., Har-Shai, L., et al. (2017) · ACS Nano · doi:10.1021/acsnano.6b04930 · Cited by 510
Self-citation
Research works printed but not linked: 2
- Watson J., 2020, BMJ., 369
- 10.1136/bmj.m1328 · doi:10.1136/bmj.m1328 · Paper page
Cited by
Diagnostics for SARS-CoV-2 infections
Kevadiya, B. D., Machhi, J., Herskovitz, J., Oleynikov, M. D., Blomberg, W. R., Bajwa, N., Soni, D., Das, S., Hasan, M., Patel, M., et al. (2021) · Nature Materials · doi:10.1038/s41563-020-00906-z · Cited by 833
Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics
Heng, W., Solomon, S., & Gao, W. (2022) · Advanced Materials · doi:10.1002/adma.202107902 · Cited by 609
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Self-citationThe emergence of AI-based wearable sensors for digital health technology: a review
Shajari, S., Kuruvinashetti, K., Komeili, A., & Sundararaj, U. (2023) · Sensors · doi:10.3390/s23239498 · Cited by 535
“…cancer [204], lung cancer [205], brain lesion [206], coronary artery disease [207], diabetes [208], esophageal adenocarcinoma [209], COVID-19 [210], heart failure [211], skin cancers [212], AI-based techniques are facilitating real-time monitoring capabilities and personalized health…”
BackgroundApplied body-fluid analysis by wearable devices
Brasier, N., Wang, J., Gao, W., Sempionatto, J. R., Dincer, C., Ates, H. C., Güder, F., Olenik, S., Schauwecker, I., Schaffarczyk, D., et al. (2024) · Nature · doi:10.1038/s41586-024-08249-4 · Cited by 298
“CRP might be a non-specific clinical inflammation marker, but it can be used to set therapeutic indications, monitor treatment success and disease progression in communicable (such as coronavirus disease 2019 (COVID-19)) and non-communicable (such as rheumatoid arthritis) diseases.”
Self-citationEmerging Telemedicine Tools for Remote COVID-19 Diagnosis, Monitoring, and Management
Lukas, H., Xu, C., Yu, Y., & Gao, W. (2020) · ACS Nano · doi:10.1021/acsnano.0c08494 · Cited by 265
Recent Progress in Sensor Arrays: From Construction Principles of Sensing Elements to Applications
Li, T., Zhu, X., Hai, X., Bi, S., & Zhang, X. (2023) · ACS Sensors · doi:10.1021/acssensors.2c02596 · Cited by 257
Lin, L. L., Alvarez-Puebla, R., Liz-Marzán, L. M., Trau, M., Wang, J., Fabris, L., Wang, X., Liu, G., Xu, S., Han, X. X., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c17502 · Cited by 247
Self-citationRole of Machine Learning Assisted Biosensors in Point-of-Care-Testing For Clinical Decisions
Bhaiyya, M., Panigrahi, D., Rewatkar, P., & Haick, H. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01582 · Cited by 230
Self-citationPoint-of-care testing detection methods for COVID-19
Song, Q., Sun, X., Dai, Z., Gao, Y., Gong, X., Zhou, B., Wu, J., & Wen, W. (2021) · Lab on a Chip · doi:10.1039/d0lc01156h · Cited by 236
Artificial Intelligence in Medical Sensors for Clinical Decisions
Haick, H., & Tang, N. (2021) · ACS Nano · doi:10.1021/acsnano.1c00085 · Cited by 231
Self-citationRecent advances of Au@Ag core–shell SERS‐based biosensors
Awiaz, G., Lin, J., & Wu, A. (2023) · Exploration · doi:10.1002/exp.20220072 · Cited by 197
Beduk, T., Beduk, D., de Oliveira Filho, J. I., Zihnioglu, F., Cicek, C., Sertoz, R., Arda, B., Goksel, T., Turhan, K., Salama, K. N., et al. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c01444 · Cited by 171
Research progress of electronic nose technology in exhaled breath disease analysis
Li, Y., Wei, X., Zhou, Y., Wang, J., & You, R. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-023-00594-0 · Cited by 165
Self-citationBreath Analysis: A Promising Tool for Disease Diagnosis—The Role of Sensors
Kaloumenou, M., Skotadis, E., Lаgopati, N., EFSTATHOPOULOS, E. P., & Tsoukalas, D. (2022) · Sensors · doi:10.3390/s22031238 · Cited by 170
“More recently, a MCNPs-based chemiresistor was developed for COVID-19 detection, with remarkable diagnostic accuracy over healthy and non-COVID infected subjects [24].”
BackgroundMolecularly imprinted polypyrrole based sensor for the detection of SARS-CoV-2 spike glycoprotein
Ratautaite, V., Boguzaite, R., Brazys, E., Ramanaviciene, A., Ciplys, E., Juozapaitis, M., Slibinskas, R., Bechelany, M., & Ramanavicius, A. (2022) · Electrochimica Acta · doi:10.1016/j.electacta.2021.139581 · Cited by 159
Jayamohan, H., Lambert, C. J., Sant, H. J., Jafek, A. R., Patel, D., Feng, H., Beeman, M., Mahmood, T., Nze, U. C., & Gale, B. K. (2020) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-020-02958-1 · Cited by 174
Motion Artifact Removal Techniques for Wearable EEG and PPG Sensor Systems
Seok, D., Lee, S.-H., Kim, M., Cho, J., & Kim, C. (2021) · Frontiers in Electronics · doi:10.3389/felec.2021.685513 · Cited by 192
“To get through this era, many researchers are currently proposing wearable biosensors as a solution to an epidemic prevention system against COVID-19 (Seo et al., 2020; Shan et al., 2020; Zhao et al., 2021; LifeSignals, 2021).”
BackgroundInfluentialIntegrated Devices for Non‐Invasive Diagnostics
Ates, H. C., Brunauer, A., von Stetten, F., Urban, G. A., Güder, F., Merkoçi, A., Früh, S. M., & Dincer, C. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202010388 · Cited by 116
Machine learning toward high-performance electrochemical sensors
Giordano, G. F., Ferreira, L. F., Bezerra, Í. R. S., Barbosa, J. A., Costa, J. N. Y., Pimentel, G. J. C., & Lima, R. S. (2023) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-023-04514-z · Cited by 167
“For instance, Shan et al. [17] addressed a noninvasive approach to detecting and following up on individuals who are at risk or have an existing COVID-19 infection, with a potential ability to serve as a pandemic control tool.”
BackgroundReview of Current COVID-19 Diagnostics and Opportunities for Further Development
Mardian, Y., Kosasih, H., Karyana, M., Neal, A., & Lau, C. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.615099 · Cited by 177
“False-positives are influenced by diet, humidity, and background contamination (59, 61).”
BackgroundSmart Materials Enabled with Artificial Intelligence for Healthcare Wearables
Zheng, Y., Tang, N., Omar, R., Hu, Z., Duong, T. D., Wang, J., Wu, W., & Haick, H. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202105482 · Cited by 164
Self-citationMagnetic-Nanosensor-Based Virus and Pathogen Detection Strategies before and during COVID-19
Wu, K., Saha, R., Su, D., Krishna, V. D., Liu, J., Cheeran, M. C. ‐., & Wang, J.-P. (2020) · ACS Applied Nano Materials · doi:10.1021/acsanm.0c02048 · Cited by 136
Self-citationDetecting COVID-19 from Breath: A Game Changer for a Big Challenge
Giovannini, G., Haick, H., & Garoli, D. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00312 · Cited by 131
Self-citationVolatile compounds in human breath: critical review and meta-analysis
Issitt, T., Wiggins, L., Veysey, M. J., Sweeney, S. T., Brackenbury, W. J., & Redeker, K. R. (2022) · Journal of Breath Research · doi:10.1088/1752-7163/ac5230 · Cited by 137
“21251712 [37] Shan B et al 2020 Multiplexed nanomaterial-based sensor array for detection of COVID-19 in exhaled breath ACS Nano 14 12125–32 [38] Subali A D, Wiyono L, Yusuf M and Zaky M F A 2022 The potential of volatile organic compounds-based breath analysis for COVID-19 screening: a systematic review and meta-anal…”
MethodChallenges of Emerging Wearable Sensors for Remote Monitoring toward Telemedicine Healthcare
Kalasin, S., & Surareungchai, W. (2023) · Analytical Chemistry · doi:10.1021/acs.analchem.2c02642 · Cited by 131
Nose-on-Chip Nanobiosensors for Early Detection of Lung Cancer Breath Biomarkers
Chaudhary, V., Taha, B. A., Lucky, L., Rustagi, S., Khosla, A., Papakonstantinou, P., & Bhalla, N. (2024) · ACS Sensors · doi:10.1021/acssensors.4c01524 · Cited by 123
Machine Learning-Based Rapid Detection of Volatile Organic Compounds in a Graphene Electronic Nose
Capman, N. S. S., Zhen, X. V., Nelson, J. T., Chaganti, V. R. S. K., Finc, R. C., Lyden, M. J., Williams, T. L., Freking, M., Sherwood, G. J., Bühlmann, P., et al. (2022) · ACS Nano · doi:10.1021/acsnano.2c10240 · Cited by 115
Exhaled breath biomarker sensing
Vasilescu, A., Hrinczenko, B. W., Swain, G. M., & Peteu, S. F. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113193 · Cited by 115
Lew, T. T. S., Aung, K. M. M., Ow, S. Y., Amrun, S. N., Sutarlie, L., Ng, L. F. P., & Su, X. (2021) · ACS Nano · doi:10.1021/acsnano.1c04091 · Cited by 118
Nanotechnology in pulmonary medicine
Doroudian, M., Neill, A. O., Loughlin, R. M., Prina‐Mello, A., Volkov, Y., & Donnelly, S. C. (2020) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2020.11.002 · Cited by 109
Li, Y., Wang, Z., Zhao, T., Li, H., Jiang, J., & Ye, J. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117958 · Cited by 122
Biosensors for the Determination of SARS-CoV-2 Virus and Diagnosis of COVID-19 Infection
Drobysh, M., Ramanavičienė, A., Viter, R., Chen, C.-F., Prentice, U., Ratautaitė, V., & Ramanavičius, A. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23020666 · Cited by 108
“Multiplexed nanomaterial-based Organic ligands COVID-19 related VOCs Electrical/ electrochemical Exhaled breath [177]”
BackgroundMethodInfluentialLow-Cost Biosensor Technologies for Rapid Detection of COVID-19 and Future Pandemics
de Araujo, W. R., Lukas, H., Torres, M. D. T., Gao, W. F., & de la Fuente‐Núñez, C. (2024) · ACS Nano · doi:10.1021/acsnano.3c01629 · Cited by 119
Tran, V. V., Tran, N. H. T., Hwang, H. S., & Chang, M. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113192 · Cited by 106
Wearable respiratory sensors for health monitoring
Yin, Z., Yang, Y., Hu, C. F., Li, J., Qin, B., & Yang, X. (2024) · NPG Asia Materials · doi:10.1038/s41427-023-00513-9 · Cited by 115
“…created a need for inexpensive and rapid screening tools for this disease, of which respiratory biomarker screening may be a very promising way to discriminate, with studies indicating that acetaldehyde and acetone may be simultaneously increased in the breath of patients with COVID-19 130 – 132 .”
Empowerment of AI algorithms in biochemical sensors
Zhou, Z., Xu, T., & Zhang, X. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117613 · Cited by 97
Microfluidics-Based Nanobiosensors for Healthcare Monitoring
Kumari, M., Gupta, V., Kumar, N., & Arun, R. K. (2023) · Molecular Biotechnology · doi:10.1007/s12033-023-00760-9 · Cited by 96
Machine learning-assisted optical nano-sensor arrays in microorganism analysis
Yang, J., Lu, S., Chen, B., Hu, F., Li, C. M., & Guo, C. (2023) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2023.116945 · Cited by 87
Liang, Q., Chan, Y.-C., Changala, P. B., Nesbitt, D. J., Ye, J., & Toscano, J. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2105063118 · Cited by 85
“Sensor arrays offer an inexpensive and practical alternative for identifying the presence of a class of compounds based on their functional groups, but they generally do not permit identification of the specific molecules present in the samples (9, 12).”
BackgroundBreath Biomarkers in Diagnostic Applications
Pham, Y. L., & Beauchamp, J. D. (2021) · Molecules · doi:10.3390/molecules26185514 · Cited by 103
“While no breath test has yet been developed that allows a reliable detection of the infection, studies have reported potential breath-borne VOC biomarkers (detected via gas chromatography ion mobility spectrometry, GC-IMS) [252] or specific breathprints (using proton transfer reaction time-of-flight mass spectrometry,…”
MethodArtificial Intelligence‐Based Medical Sensors for Healthcare System
Chen, M., Cui, D., Haick, H., & Tang, N. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300009 · Cited by 102
Self-citationWang, D., Luo, D., Zhang, Y., Zhao, Y. H., Zhou, G., Shui, L., Chen, Z., & Wang, X. (2020) · Nano Energy · doi:10.1016/j.nanoen.2020.105602 · Cited by 84
Zhao, W., Zhou, Y., Feng, Y. X., Niu, X., Zhao, Y., Zhao, J., Dong, Y., Tan, M., Xianyu, Y., & Chen, Y. (2023) · ACS Nano · doi:10.1021/acsnano.3c02941 · Cited by 90
Silver nanoparticles as a potential treatment against SARS‐CoV ‐2: A review
Pilaquinga, F., Morey, J., Arias, M. T., Seqqat, R., & Piña, M. D. L. N. (2021) · Wiley Interdisciplinary Reviews Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1707 · Cited by 86
“A wide range of nanomaterials are used for virus detection, such as metal NPs (Cho & Glenn, 2020; Dougan, Karlsson, Smith, & Graham, 2007; Shan et al., 2020), polymeric NPs (Zhang et al.”
BackgroundPoint-of-care diagnostics: recent developments in a pandemic age
Harpaldas, H., Arumugam, S., Rodriguez, C. C., Kumar, B. A., Shi, V. Y., & Sia, S. K. (2021) · Lab on a Chip · doi:10.1039/d1lc00627d · Cited by 91
Reproducible Breath Metabolite Changes in Children with SARS-CoV-2 Infection
Berna, A. Z., Akaho, E. H., Harris, R. M., Congdon, M., Korn, E., Neher, S., M’Farrej, M., Burns, J. E., & John, A. R. O. (2021) · ACS Infectious Diseases · doi:10.1021/acsinfecdis.1c00248 · Cited by 93
Advancement in COVID‐19 detection using nanomaterial‐based biosensors
Truong, P. L., Yin, Y., Lee, D., & Ko, S. H. (2023) · Exploration · doi:10.1002/exp.20210232 · Cited by 91
Sitjar, J., Liao, J., Lee, H., Tsai, H., Wang, J., & Liu, P. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113153 · Cited by 78
Self-citationPolyaniline/Ti3C2Tx functionalized mask sensors for monitoring of CO2 and human respiration rate
Wu, G., Du, H., Pakravan, K., Kim, W., Cha, Y. L., Chiang, S.-T., Beidaghi, M., Zhang, X., Kim, S. H., Pan, X., et al. (2023) · Chemical Engineering Journal · doi:10.1016/j.cej.2023.146228 · Cited by 75
Nanomaterial Based Biosensors for Detection of Viruses Including SARS-CoV-2: A Review
Bisht, A., Mishra, A., Bisht, H. S., & Tripathi, R. M. (2021) · Journal of Analysis and Testing · doi:10.1007/s41664-021-00200-0 · Cited by 73
“In a recent publication, an AuNP based sensor was made for detecting SARS-CoV-2 from exhaled breath [62].”
MethodGong, F., Wei, H.-X., Qi, J., Ma, H., Liu, L., Weng, J., Zheng, X., Li, Q., Zhao, D., Fang, H., et al. (2021) · ACS Sensors · doi:10.1021/acssensors.1c00773 · Cited by 73
A mask-based diagnostic platform for point-of-care screening of Covid-19
Daniels, J., Wadekar, S., DeCubellis, K., Jackson, G. W., Chiu, A. S., Pagneux, Q., Saada, H., Engelmann, I., Ogiez, J., Loze-Warot, D., et al. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2021.113486 · Cited by 67
“Different from exhaled breath (EB), which is based on exhalation of volatile organic compounds (VOCs NO, CO2, NH3, H2O2, etc.) (Shan et al., 2020), EBC contains lower respiratory droplets which can be analyzed by RT-PCR (Ryan et al., 2021).”
Leong, S. X., Leong, Y. X., Koh, C. S. L., Tan, E. X., Nguyen, L. B. T., Chen, J. R. T., Chong, C., Pang, D. W. C., Sim, H. Y. F., Liang, X., et al. (2022) · Chemical Science · doi:10.1039/d2sc02981b · Cited by 69
Profiles of Volatile Biomarkers Detect Tuberculosis from Skin
Vishinkin, R., Busool, R., Mansour, E., Fish, F., Esmail, A., Kumar, P., Gharaa, A., Cancilla, J. C., Torrecilla, J. S., Šķenders, Ģ., et al. (2021) · Advanced Science · doi:10.1002/advs.202100235 · Cited by 64
Self-citationKazzy, M. E., Weerakkody, J. S., Hurot, C., Mathey, R., Buhot, A., Scaramozzino, N., & Hou, Y. (2021) · Biosensors · doi:10.3390/bios11080244 · Cited by 70
“Furthermore, a recent study showed the possibility of detecting viral infections such as COVID 19 through exhaled breath analysis [4].”
BackgroundMethodInfluentialDevelopment of smart wearable sensors for life healthcare
Luo, H., & Gao, B. (2021) · Engineered Regeneration · doi:10.1016/j.engreg.2021.10.001 · Cited by 75
Surface-Enhanced Raman Scattering-Based Multimodal Techniques: Advances and Perspectives
Tan, E. X., Zhong, Q., Chen, J. R. T., Leong, Y. X., Leon, G. K., Tran, C. T., Phang, I. Y., & Ling, X. Y. (2024) · ACS Nano · doi:10.1021/acsnano.4c12996 · Cited by 64
Recent Progress in Nanotechnology for COVID-19 Prevention, Diagnostics and Treatment
Rasmi, Y., Sahbani, S. K., Nemati, M., & Choi, J. R. (2021) · Nanomaterials · doi:10.3390/nano11071788 · Cited by 61
“One study has demonstrated the detection of COVID-19 biomarkers from exhaled breath using a AuNP-based sensor [86].”
MethodZhang, S., Suresh, L., Yang, J., Zhang, X., & Tan, S. C. (2022) · Advanced Intelligent Systems · doi:10.1002/aisy.202100194 · Cited by 59
Hidayat, S. N., Julian, T., Dharmawan, A. B., Puspita, M., Chandra, L., Rohman, A., Julia, M., Rianjanu, A., Nurputra, D. K., Trıyana, K., et al. (2022) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2022.102323 · Cited by 55
“…the system quality, we evaluated the GeNose C19 in terms of its performances in comparison to other commercial and developed e-nose devices (e.g., PEN3 e-nose, aeoNose, SpiroNose, and nanomaterial-based e-nose [42 – 45]), which have been routinely tested for COVID-19 detection (Table 4).”
Biswas, G. C., Choudhury, S., Rabbani, M. M., & Das, J. (2022) · Chemosensors · doi:10.3390/chemosensors10070269 · Cited by 63
Harun‐Ur‐Rashid, M., Foyez, T., Jahan, I., Pal, K., & Imran, A. B. (2022) · RSC Advances · doi:10.1039/d2ra01293f · Cited by 58
Subali, A. D., Wiyono, L., Yusuf, M. F. R. H., & Zaky, M. F. A. (2021) · Diagnostic Microbiology and Infectious Disease · doi:10.1016/j.diagmicrobio.2021.115589 · Cited by 57
Özer, T., & Henry, C. S. (2021) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/abfc9f · Cited by 54
Toward a new generation of permeable skin electronics
Yang, J., Zhang, Z., Zhou, P., Zhang, Y., Liu, Y., Xu, Y., Gu, Y., Qin, S., Haick, H., & Wang, Y. (2023) · Nanoscale · doi:10.1039/d2nr06236d · Cited by 54
Self-citationHuang, S., Croy, A., Bierling, A. L., Khavrus, V. O., Panes‐Ruiz, L. A., Dianat, A., Ibarlucea, B., & Cuniberti, G. (2023) · Applied Physics Reviews · doi:10.1063/5.0132177 · Cited by 56
Breath analysis for the screening and diagnosis of diseases
Nidheesh, V. R., Mohapatra, A. K., Unnikrishnan, V. K., Sinha, R. K., Nayak, R., Kartha, V. B., & Chidangil, S. (2020) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2020.1848857 · Cited by 52
“have developed a multiplexed nanomaterial-based sensor array for detection of COVID-19 using the exhaled breath with an accuracy of 94% in differentiating patients from control.([121]) Miniature e-noses are”
MethodA Multifunctional Neutralizing Antibody‐Conjugated Nanoparticle Inhibits and Inactivates SARS‐CoV‐2
Cai, X., Chen, M., Promiński, A., Lin, Y., Ankenbruck, N., Rosenberg, J. N., Nguyen, M., Shi, J., Τοματσίδου, Α., Randall, G. C., et al. (2021) · Advanced Science · doi:10.1002/advs.202103240 · Cited by 53
Proof of concept for real-time detection of SARS CoV-2 infection with an electronic nose
Snitz, K., Andelman‐Gur, M. M., Pinchover, L., Weissgross, R., Weissbrod, A., Mishor, E., Zoller, R., Linetsky, V., Medhanie, A., Shushan, S., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0252121 · Cited by 51
Role of Wearable Sensing Technology to Manage Long COVID
Khondakar, K. R., & Kaushik, A. K. (2022) · Biosensors · doi:10.3390/bios13010062 · Cited by 56
“developed a nanomaterial-based sensor array with multiplexed capabilities for detection and monitoring of COVID-19 from exhaled breath [96].”
BackgroundAlternative Micro/Nanofabrication Approaches for Wearable Electronics
Zhang, J., & Wang, M. (2026) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00801 · Cited by 56
Liangou, A., Tasoglou, A., Huber, H. J., Wistrom, C., Brody, K., Menon, P. G., Bebekoski, T., Menschel, K., Davidson-Fiedler, M., DeMarco, K., et al. (2021) · EClinicalMedicine · doi:10.1016/j.eclinm.2021.101207 · Cited by 55
“Multiple studies presented the use of gas chromatography-ion mobility spectrometry (GC-IMS) for the breath analysis [14-17].”
Emerging diagnostic tools for detection of COVID-19 and perspective
Verma, N., Patel, D., & Pandya, A. (2020) · Biomedical Microdevices · doi:10.1007/s10544-020-00534-z · Cited by 50
Huang, Y., Yang, F., Liu, S., Wang, R., Guo, J., & Ma, X. (2021) · Research · doi:10.34133/2021/9847285 · Cited by 51
“Dynamic respiratory monitoring Bluetooth module (HJ-131MH) [4] MCU (STM32G030) [3] Analog input amplifier [1][2] Breath sensor”
BackgroundBiosensors as Nano-Analytical Tools for COVID-19 Detection
Pradhan, A., Lahare, P., Sinha, P., Singh, N., Gupta, B., Kuča, K., Ghosh, K. K., & Krejcar, O. (2021) · Sensors · doi:10.3390/s21237823 · Cited by 51
Mohamadbeigi, N., Shooshtari, L., Fardindoost, S., Vafaiee, M., zad, A. I., & Mohammadpour, R. (2024) · Scientific Reports · doi:10.1038/s41598-024-51862-6 · Cited by 51
Nanodiagnostics to Face SARS-CoV‑2 and Future Pandemics: From an Idea to the Market and Beyond
Rosati, G., Idili, A., Parolo, C., Fuentes‐Chust, C., Calucho, E., Hu, L., Silva, C. D. C. C., Rivas, L., Nguyen, E. P., Bergua, J. F., et al. (2021) · ACS Nano · doi:10.1021/acsnano.1c06839 · Cited by 55
Wasfi, A., Awwad, F. R., Qamhieh, N. N., Almurshidi, B., Palakkott, A. R., & Gelovani, J. G. (2022) · Scientific Reports · doi:10.1038/s41598-022-22249-2 · Cited by 47
Li, J., Hannon, A., Yu, G. Y., Idziak, L. A., Sahasrabhojanee, A., Govindarajan, P., Maldonado, Y., Ngo, K., Abdou, J. P., Mai, N., et al. (2023) · ACS Sensors · doi:10.1021/acssensors.3c00367 · Cited by 47
Cernat, A., Groza, A. P., Tertiş, M., Feier, B., Hosu, O., & Cristea, C. (2024) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2024.117999 · Cited by 61
Bedük, T., Durmus, C., Hanoglu, S. B., Beduk, D., Salama, K. N., Göksel, T., Turhan, K., & Tımur, S. (2021) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2021.116329 · Cited by 46
Gutiérrez-Rodelo, C., Salinas, R. A., Armenta-Jaime, E., Armenta, S., Galdámez‐Martínez, A., Castillo-Blum, S. E., la Vega, H. A., Grace, A. N., Aguilar-Salinas, C. A., Rodelo, J. G., et al. (2022) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2021.214402 · Cited by 48
“Other semiconducting nanostructures such as Si, CdSe, and lanthanide materials have also been reported to detect SARS-CoV-2 proteins or antibodies [72-76].”
BackgroundDiagnostic Approaches For COVID-19: Lessons Learned and the Path Forward
Alafeef, M., & Pan, D. (2022) · ACS Nano · doi:10.1021/acsnano.2c01697 · Cited by 45
Zhou, K., & Liu, Y. (2021) · Sensors · doi:10.3390/s21144826 · Cited by 44
Park, J., & Tabata, H. (2021) · ACS Omega · doi:10.1021/acsomega.1c01435 · Cited by 44
Cho, S., Jin, X., Gong, X., Yang, S., Cui, J., & Strano, M. S. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c02889 · Cited by 43
Nanomaterial-Based Sensors for Exhaled Breath Analysis: A Review
Velumani, M., Prasanth, A., Narasimman, S., Chandrasekhar, A., Sampson, S. A., Meher, S. R., Rajalingam, S., Rufus, E., & Alex, Z. C. (2022) · Coatings · doi:10.3390/coatings12121989 · Cited by 44
Laghrib, F., Saqrane, S., Bouabi, Y. E., Farahi, A., Bakasse, M., Lahrich, S., & Mhammedi, M. A. E. (2020) · Microchemical Journal · doi:10.1016/j.microc.2020.105606 · Cited by 45
State-of-the-Art of Nanodiagnostics and Nanotherapeutics against SARS-CoV-2
Derakhshan, M. A., Amani, A., & Majidi, R. F. (2021) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c22381 · Cited by 43
Nanomaterials‐based sensors for the detection of COVID‐19: A review
Naikoo, G. A., Arshad, F., Hassan, I. U., Awan, T., Salim, H., Pedram, M. Z., Ahmed, W., Patel, V., Karakoti, A. S., & Vinu, A. (2022) · Bioengineering & Translational Medicine · doi:10.1002/btm2.10305 · Cited by 43
“reported a nanomaterial-based sensor array showing multiplexed properties for detecting and monitoring COVID-19 from exhaled breath.(12) This sensor comprises of a sensing layer that could”
BackgroundWilson, A. D., & Forse, L. B. (2023) · Sensors · doi:10.3390/s23062887 · Cited by 47
“95 Differentiated COVID-19 from controls and other lung infections [44]”
BackgroundMethodNovel approaches for rapid detection of COVID-19 during the pandemic: A review
Ilkhani, H., Hedayat, N., & Farhad, S. (2021) · Analytical Biochemistry · doi:10.1016/j.ab.2021.114362 · Cited by 42
“[38] is focused on nonmaterial-based sensor array with”
Asdaq, S. M. B., Ikbal, A. M. A., Sahu, R. K., Bhattacharjee, B., Paul, T., Deka, B., Fattepur, S., Widyowati, R., Vijaya, J., Mohaini, M. A., et al. (2021) · Nanomaterials · doi:10.3390/nano11071841 · Cited by 45
“The stated test could assist in rapid screening of large populations due to its simplicity and high sensitivity, and it could also be utilized as a valuable technique for COVID-19 screening [68].”
MethodWang, H., Chen, M., Sun, Y., Xu, L. Y., Li, F., & Han, J. (2022) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03623 · Cited by 41
Bordbar, M. M., Samadinia, H., Hajian, A., Sheini, A., Safaei, E., Aboonajmi, J., Arduini, F., Sharghi, H., Hashemi, P., Khoshsafar, H., et al. (2022) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2022.132379 · Cited by 41
“system can detect and differentiate between the breath metabolites of patients, healthy people and patients with non-Covid respiratory diseases, providing accuracy in the range of 90%–94% [15].”
BackgroundSharma, R., Zang, W., Tabartehfarahani, A., Lam, A., Huang, X., Sivakumar, A. D., Thota, C., Yang, S., Dickson, R. P., Sjoding, M. W., et al. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.0982 · Cited by 42
Ultrasensitive SARS-CoV-2 diagnosis by CRISPR-based screen-printed carbon electrode
Wu, L., Wang, X., Wu, C., Cao, X., Tang, T., Huang, H., & Huang, X. (2022) · Analytica Chimica Acta · doi:10.1016/j.aca.2022.340120 · Cited by 40
Intelligent Identification of Cerebrospinal Fluid for the Diagnosis of Parkinson’s Disease
Chen, H., Guo, S., Zhuang, Z., Ouyang, S., Lin, P., Zheng, Z., You, Y., Zhou, X. Y., Li, Y., Lu, J., et al. (2024) · Analytical Chemistry · doi:10.1021/acs.analchem.3c04849 · Cited by 39
Breath Metabolites to Diagnose Infection
Berna, A. Z., & John, A. R. O. (2021) · Clinical Chemistry · doi:10.1093/clinchem/hvab218 · Cited by 41
“(19) developed a breath device composed of a nanomaterial-based hybrid sensor array with multiplexed detection.”
Metadata
- Authors
- Shan, B., Broza, Y. Y., Li, W., Wang, Y., Wu, S., Liu, Z., Wang, J., Gui, S., Wang, L., Zhang, Z., Liu, W., Zhou, S., Jin, W., Zhang, Q., Hu, D., Lin, L., Zhang, Q., Li, W., Wang, J., Liu, H., Pan, Y., & Haick, H.
- Affiliations
- University of Science and Technology of China (CN)
- Technion – Israel Institute of Technology (IL)
- First Affiliated Hospital of Anhui Medical University (CN)
- Department of Respiratory Disease, Anhui Provincial Chest Hospital, 230000, Hefei, Anhui Province, People’s Republic of China
- Corresponding author
- Liu, Hu
- Pan, Yueyin
- Haick, Hossam
- ORCID
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2020-08-18
- Volume
- 14
- Issue
- 9
- Pages
- 12125-12132
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W3049021859
- Cited by
- 384
- References
- 26
- Citations by year
- 2026: 10 · 2025: 33 · 2024: 51 · 2023: 54 · 2022: 90 · 2021: 115 · 2020: 30
- FWCI
- 22.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- ACS Nano (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Technion-Israel Institute of Technology
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Chemical Sensor Technologies
- Health Sciences › Medicine › Infectious Diseases › SARS-CoV-2 detection and testing
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Gas Sensing Nanomaterials and Sensors
- Keywords
- COVID-19 detection, breath analysis, multiplexed sensing, non-invasive diagnosis, disease-specific biomarkers, point-of-care screening, epidemic control, SARS-CoV-2
- MeSH terms
- Data Accuracy, Betacoronavirus, COVID-19, SARS-CoV-2, Breath Tests, China, Female, Humans, Male, Middle Aged, Pneumonia, Viral, Respiratory System, Sensitivity and Specificity, Biomarkers, Coronavirus Infections, Asian People, Nanostructures, Pandemics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.