Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 387

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Breathable Ti3C2Tx MXene/Protein Nanocomposites for Ultrasensitive Medical Pressure Sensor with Degradability in Solvents

Chao, Mingyuan, He, Lingzhang, Gong, Min, Li, Na, Li, Xiaobin, Peng, Longfei, Shi, Feng, Zhang, Liqun, Wan, Pengbo·2021·ACS Nano

Abstract

Flexible, breathable, and degradable pressure sensors with excellent sensing performance are drawing tremendous attention for various practical applications in wearable artificial skins, healthcare monitoring, and artificial intelligence due to their flexibility, breathability, lightweight, decreased electronic rubbish, and environmentally friendly impact. However, traditional plastic or elastomer substrates with impermeability, uncomfortableness, mechanical mismatches, and nondegradability greatly restricted their practical applications. Therefore, the fabrication of such pressure sensors with high flexibility, facile degradability, and breathability is still a critical challenge and highly desired. Herein, we present a wearable, breathable, degradable, and highly sensitive MXene/protein nanocomposites-based pressure sensor. The fabricated MXene/protein-based pressure sensor is assembled from a breathable conductive MXene coated silk fibroin nanofiber (MXene-SF) membrane and a silk fibroin nanofiber membrane patterned with a MXene ink-printed (MXene ink-SF) interdigitated electrode, which can serve as the sensing layer and the electrode layer, respectively. The assembled pressure sensor exhibits a wide sensing range (up to 39.3 kPa), high sensitivity (298.4 kPa –1 for 1.4–15.7 kPa; 171.9 kPa –1 for 15.7–39.3 kPa), fast response/recovery time (7/16 ms), reliable breathability, excellent cycling stability over 10 000 cycles, good biocompatibility, and robust degradability. Furthermore, it shows great sensing performance in monitoring human psychological signals, acting as an artificial skin for the quantitative illustration of pressure distribution, and wireless biomonitoring in real time. Considering the biodegradable and breathable features, the sensor may become promising to find potential applications in smart electronic skins, human motion detection, disease diagnosis, and human–machine interaction.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.1c00472

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 387

Metadata

Authors
Chao, M., He, L., Gong, M., Li, N., Li, X., Peng, L., Shi, F., Zhang, L., & Wan, P.
Venue
ACS Nano
Published
2021-06-03
Volume
15
Issue
6
Pages
9746-9758
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W3165326048
Cited by
387
References
8
FWCI
18.27
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.