CoChat

High-Speed Multipass Coulter Counter with Ultrahigh Resolution

Edwards, Martin A., German, Sean R., Dick, Jeffrey E., Bard, Allen J., White, Henry S. · 2015 · ACS Nano
Cited by 68

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Coulter counters measure the size of particles in solution by passing them through an orifice and measuring a resistive pulse, i.e., a drop in the ionic current flowing between two electrodes placed on either side of the orifice. The magnitude of the pulse gives information on the size of the particle; however, resolution is limited by variability in the path of the translocation, due to the Brownian motion of the particle. We present a simple yet powerful modified Coulter counter that uses programmable data acquisition hardware to switch the voltage after sensing the resistive pulse of a nanoparticle passing through the orifice of a nanopipet. Switching the voltage reverses the direction of the driving force on the particle and, when this detect-switch cycle is repeated, allows us to pass an individual nanoparticle through the orifice thousands of times. By measuring individual particles more than 100 times per second we rapidly determine the distribution of the resistive pulses for each particle, which allows us to accurately determine the mean pulse amplitude and deliver considerably improved size resolution over a conventional Coulter counter. We show that single polystyrene nanoparticles can be shuttled back and forth and monitored for minutes, leading to a precisely determined mean blocking current equating to sub-angstrom size resolution.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/acsnano.5b05554

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Metadata

Authors
Edwards, M. A., German, S. R., Dick, J. E., Bard, A. J., & White, H. S.
Venue
ACS Nano
Published
2015-11-12
Volume
9
Issue
12
Pages
12274-12282
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2191488834
Cited by
68
References
4
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: High-Speed Multipass Coulter Counter with Ultrahigh Resolution. https://app.cochat.ai/papers/10.1021/acsnano.5b05554
The paper
Edwards, M. A., German, S. R., Dick, J. E., Bard, A. J., & White, H. S. (2015). High-Speed Multipass Coulter Counter with Ultrahigh Resolution. ACS Nano. https://doi.org/10.1021/acsnano.5b05554

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.