The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Enhanced Afterglow Performance of Persistent Luminescence Implants for Efficient Repeatable Photodynamic Therapy
Abstract
Persistent luminescence nanoparticles (PLNPs) have been used for bioimaging without autofluorescence background interference, but the poor afterglow performance impedes their further applications in cancer therapy. To overcome the Achilles’ heel of PLNPs, herein we report the construction of injectable persistent luminescence implants (denoted as PL implants) as a built-in excitation source for efficient repeatable photodynamic therapy (PDT). The injectable ZGC (ZnGa 1.996 O 4:Cr 0.004 ) PL implants were prepared by dissolving ZGC PLNPs in poly(lactic- co -glycolic acid)/ N -methylpyrrolidone oleosol, which demonstrated much stronger persistent luminescence (PersL) intensity and longer PersL lifetime than that of ZGC PLNPs both in vitro and in vivo . More importantly, the intratumorally fixed ZGC PL implants can serve as a built-in excitation source for repeatable light emitting diode (LED) and PersL-excited PDT upon and after periodic LED irradiation, which leads to the overall improvement of therapeutic effectiveness for efficient tumor growth suppression. This work represents efficient repeatable PDT based on the injectable yet periodically rechargeable ZGC PL implants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
O’Connor, A. E., Gallagher, W. M., & Byrne, A. T. (2009) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.2009.00585.x · Cited by 1,191
Cited by
Clinical development and potential of photothermal and photodynamic therapies for cancer
Li, X., Lovell, J. F., Yoon, J., & Chen, X. (2020) · Nature Reviews Clinical Oncology · doi:10.1038/s41571-020-0410-2 · Cited by 3,456
Self-citationReactive Oxygen Species (ROS)-Based Nanomedicine
Yang, B., Chen, Y., & Shi, J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00626 · Cited by 2,443
Stimuli-responsive nanocarriers for drug delivery, tumor imaging, therapy and theranostics
Mi, P. (2020) · Theranostics · doi:10.7150/thno.38069 · Cited by 830
Photodynamic Therapy—Current Limitations and Novel Approaches
Gunaydin, G., Gedik, M. E., & Ayan, S. (2021) · Frontiers in Chemistry · doi:10.3389/fchem.2021.691697 · Cited by 599
Ni, X., Zhang, X., Duan, X., Zheng, H.-L., Xue, X.-S., & Ding, D. (2019) · Nano Letters · doi:10.1021/acs.nanolett.8b03936 · Cited by 483
A generic approach towards afterglow luminescent nanoparticles for ultrasensitive in vivo imaging
Jiang, Y., Huang, J., Zhen, X., Zeng, Z., Li, J., Xie, C., Miao, Q., Chen, J., Chen, P., & Pu, K. (2019) · Nature Communications · doi:10.1038/s41467-019-10119-x · Cited by 311
Photodynamic Therapy: A Compendium of Latest Reviews
Algorri, J. F., Ochoa, M., Roldán-Varona, P., Rodríguez-Cobo, L., & López-Higuera, J. M. (2021) · Cancers · doi:10.3390/cancers13174447 · Cited by 263
Qi, J., Sun, C., Li, D., Zhang, H., Yu, W., Zebibula, A., Lam, J. W. Y., Xi, W., Zhu, L., Cai, F., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b02452 · Cited by 226
Metadata
- Authors
- Fan, W., Lu, N., Xu, C., Liu, Y., Lin, J., Wang, S., Shen, Z., Yang, Z., Qu, J., Wang, T., Chen, S., Huang, P., & Chen, X.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-05-26
- Volume
- 11
- Issue
- 6
- Pages
- 5864-5872
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2617682450
- Cited by
- 167
- References
- 1
- FWCI
- 8.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.