The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Autofluorescence-Free Targeted Tumor Imaging Based on Luminous Nanoparticles with Composition-Dependent Size and Persistent Luminescence
Abstract
Optical bioimaging is an indispensable tool in modern biology and medicine, but the technique is susceptible to autofluorescence interference. Persistent nanophosphors provide an easy-to-perform and highly efficient means to eliminate tissue autofluorescence. However, direct synthesis of persistent nanophosphors with tunable properties to meet different bioimaging requirements remains largely unexplored. In this work, zinc gallogermanate (Zn 1+ x Ga 2–2 x Ge x O 4:Cr, 0 ≤ x ≤ 0.5, ZGGO:Cr) persistent luminescence nanoparticles with composition-dependent size and persistent luminescence are reported. The size of the ZGGO:Cr nanoparticles gradually increases with the increase of x in the chemical formula. Moreover, the intensity and decay time of persistent luminescence in ZGGO:Cr nanoparticles can also be fine-tuned by simply changing x in the formula. In vivo bioimaging tests demonstrate that ZGGO:Cr nanoparticles can efficiently eliminate tissue autofluorescence, and the nanoparticles also show good promise in long-term bioimaging as they can be easily reactivated in vivo . Furthermore, an aptamer-guided ZGGO:Cr bioprobe is constructed, and it displays excellent tumor-specific accumulation. The ZGGO:Cr nanoparticles are ideal for autofluorescence-free targeted bioimaging, indicating their great potential in monitoring cellular networks and construction of guiding systems for surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Second window for in vivo imaging
Smith, A. M., Mancini, M. C., & Nie, S. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.326 · Cited by 2,848
Cited by
Concepts of nanoparticle cellular uptake, intracellular trafficking, and kinetics in nanomedicine
Donahue, N. D., Acar, H., & Wilhelm, S. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.04.008 · Cited by 944
Persistent luminescence instead of phosphorescence: History, mechanism, and perspective
Xu, J., & Tanabe, S. (2019) · Journal of Luminescence · doi:10.1016/j.jlumin.2018.09.047 · Cited by 680
Molecular Probes for Autofluorescence-Free Optical Imaging
Jiang, Y., & Pu, K. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00506 · Cited by 426
Photoluminescent Nanoparticles for Chemical and Biological Analysis and Imaging
Algar, W. R., Massey, M., Rees, K., Higgins, R., Krause, K. D., Darwish, G. H., Peveler, W. J., Xiao, Z., Tsai, H.-Y., Gupta, R., et al. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01176 · Cited by 356
Imaging and therapeutic applications of persistent luminescence nanomaterials
Liu, J., Lécuyer, T., Seguin, J., Mignet, N., Scherman, D., Viana, B., & Richard, C. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.10.015 · Cited by 313
Metadata
- Authors
- Wang, J., Ma, Q., Hu, X.-X., Liu, H., Zheng, W., Chen, X., Yuan, Q., & Tan, W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2017-08-08
- Volume
- 11
- Issue
- 8
- Pages
- 8010-8017
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2743671147
- Cited by
- 200
- References
- 1
- FWCI
- 7.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.