Skin is the largest organ of the human body, and it offers a diagnostic interface rich with vital biological signals from the inner organs, blood vessels, muscles, and dermis/epidermis. Soft, flexible, and stretchable electronic devices provide a novel platform to interface with soft tissues for robotic feedback and control, regenerative medicine, and continuous health monitoring. Here, we introduce the term "lab-on-skin" to describe a set of electronic devices that have physical properties, such as thickness, thermal mass, elastic modulus, and water-vapor permeability, which resemble those of the skin. These devices can conformally laminate on the epidermis to mitigate motion artifacts and mismatches in mechanical properties created by conventional, rigid electronics while simultaneously providing accurate, non-invasive, long-term, and continuous health monitoring. Recent progress in the design and fabrication of soft sensors with more advanced capabilities and enhanced reliability suggest an impending translation of these devices from the research lab to clinical environments. Regarding these advances, the first part of this manuscript reviews materials, design strategies, and powering systems used in soft electronics. Next, the paper provides an overview of applications of these devices in cardiology, dermatology, electrophysiology, and sweat diagnostics, with an emphasis on how these systems may replace conventional clinical tools. The review concludes with an outlook on current challenges and opportunities for future research directions in wearable health monitoring.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsnano.7b04898

Cites

208 of 208 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 208 references

Research works printed but not linked: 8

  1. Jog N. K., 2013, Electronics in Medicine and Biomedical Instrumentation
  2. Ravariu C., 2001, Semiconductor Conference, 2001. CAS 2001, 379
  3. Rieger M. M., 1974, J. Soc. Cosmet. Chem., 25, 253
  4. Friberg S. E., 1990, J. Soc. Cosmet. Chem., 41, 155
  5. 10.1046/j.1467-2494.2000.00037.x · doi:10.1046/j.1467-2494.2000.00037.x · Paper page
  6. Robinson, A. J.; Snyder-Mackler, L.Clinical Electrophysiology: Electrotherapy and Electrophysiologic Testing;Lippincott Williams & Wilkins:Philadelphia, PA, 2008.
  7. 10.1073/pnas.1605720113 · DOI · Paper page
  8. 10.1063/1.4905015 · DOI

Cited by

Items 401–500 of 1,002

Metadata

Authors
Liu, Y., Pharr, M., & Salvatore, G. A.
Affiliations
  • University of Illinois Urbana-Champaign (US)
  • Texas A&M University (US)
  • ETH Zurich (CH)
Corresponding author
  • Liu, Yuhao
  • Pharr, Matt
  • Salvatore, Giovanni Antonio
Venue
ACS Nano
Published
2017-09-25
Volume
11
Issue
10
Pages
9614-9635
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W2755528635
Cited by
1,725
References
211
Citations by year
2026: 139 · 2025: 150 · 2024: 202 · 2023: 178 · 2022: 226 · 2021: 267 · 2020: 258 · 2019: 197 · 2018: 103 · 2017: 3
FWCI
12.31
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
  • ARCA (Università Ca' Foscari Venezia) (submittedVersion)
Funders
Texas A and M Engineering Experiment Station, Texas A and M University
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Nanomaterials and Printing Technologies
Keywords
flexible electronics, stretchable electronics, wearable health monitoring, soft sensors, non-invasive monitoring, cardiac monitoring, dermatology, electrophysiology
MeSH terms
Wearable Electronic Devices, Electronics, Equipment Design, Humans, Monitoring, Physiologic, Skin

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.