The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Glucose Sensing with Phenylboronic Acid Functionalized Hydrogel-Based Optical Diffusers
Open accessAbstract
Phenylboronic acids have emerged as synthetic receptors that can reversibly bind to cis-diols of glucose molecules. The incorporation of phenylboronic acids in hydrogels offers exclusive attributes; for example, the binding process with glucose induces Donnan osmotic pressure resulting in volumetric changes in the matrix. However, their practical applications are hindered because of complex readout approaches and their time-consuming fabrication processes. Here, we demonstrate a microimprinting method to fabricate densely packed concavities in phenylboronic acid functionalized hydrogel films. A microengineered optical diffuser structure was imprinted on a phenylboronic acid based cis-diol recognizing motif prepositioned in a hydrogel film. The diffuser structure engineered on the hydrogel was based on laser-inscribed arrays of imperfect microlenses that focused the incoming light at different focal lengths and direction resulting in a diffused profile of light in transmission and reflection readout modes. The signature of the dimensional modulation was detected in terms of changing focal lengths of the microlenses due to the volumetric expansion of the hydrogel that altered the diffusion spectra and transmitted beam profile. The transmitted optical light spread and intensity through the sensor was measured to determine variation in glucose concentrations at physiological conditions. The sensor was integrated in a contact lens and placed over an artificial eye. Artificial stimulation of variation in glucose concentration allowed quantitative measurements using a smartphone's photodiode. A smartphone app was utilized to convert the received light intensity to quantitative glucose concentration values. The developed sensing platform offers low cost, rapid fabrication, and easy detection scheme as compared to other optical sensing counterparts. The presented detection scheme may have applications in wearable real-time biomarker monitoring devices at point-of-care settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogel Based Sensors for Biomedical Applications: An Updated Review
Tavakoli, J., & Tang, Y. (2017) · Polymers · doi:10.3390/polym9080364 · Cited by 434
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370
Tear glucose analysis for the noninvasive detection and monitoring of diabetes mellitus
Baca, J. T., Finegold, D. N., & Asher, S. A. (2007) · The Ocular Surface · doi:10.1016/s1542-0124(12)70094-0 · Cited by 187
Reusable, Robust, and Accurate Laser-Generated Photonic Nanosensor
Yetisen, A. K., Montelongo, Y., da Cruz Vasconcellos, F., Martinez-Hurtado, J. L., Neupane, S., Butt, H., Qasim, M. M., Blyth, J., Burling, K., Carmody, J. B., et al. (2014) · Nano Letters · doi:10.1021/nl5012504 · Cited by 123
Self-citationLight‐Directed Writing of Chemically Tunable Narrow‐Band Holographic Sensors
Yetisen, A. K., Butt, H., da Cruz Vasconcellos, F., Montelongo, Y., Davidson, C. A. B., Blyth, J., Chan, L., Carmody, J. B., Vignolini, S., Steiner, U., et al. (2014) · Advanced Optical Materials · doi:10.1002/adom.201300375 · Cited by 123
Self-citationColor-selective holographic retroreflector array for sensing applications
Ahmed, R., Yetisen, A. K., Yun, S. H., & Butt, H. (2016) · Light: Science & Applications · doi:10.1038/lsa.2016.214 · Cited by 57
Self-citationBajgrowicz-Cieslak, M., Alqurashi, Y., Elshereif, M. I., Yetisen, A. K., Hassan, M. U., & Butt, H. (2017) · RSC Advances · doi:10.1039/c7ra11184c · Cited by 32
Self-citation
Cited by
Krämer, J., Kang, R., Grimm, L. M., De Cola, L., Picchetti, P., & Biedermann, F. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00746 · Cited by 449
Wearable Contact Lens Biosensors for Continuous Glucose Monitoring Using Smartphones
Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H. (2018) · ACS Nano · doi:10.1021/acsnano.8b00829 · Cited by 371
Self-citationMu, J., Jung de Andrade, M., Fang, S., Wang, X., Gao, E., Li, N., Kim, S. H., Wang, H., Hou, C., Zhang, Q., et al. (2019) · Science · doi:10.1126/science.aaw2403 · Cited by 357
The Era of Digital Health: A Review of Portable and Wearable Affinity Biosensors
Tu, J., Torrente‐Rodríguez, R. M., Wang, M., & Gao, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.201906713 · Cited by 357
Hydrogel-Based Sensor Networks: Compositions, Properties, and Applications—A Review
Sun, X., Agate, S., Salem, K. S., Lucia, L., & Pal, L. (2021) · ACS Applied Bio Materials · doi:10.1021/acsabm.0c01011 · Cited by 264
Healthcare Applications of pH-Sensitive Hydrogel-Based Devices: A Review
Hendi, A., Umair Hassan, M., Elsherif, M., Alqattan, B., Park, S., Yetisen, A. K., & Butt, H. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s245743 · Cited by 151
Self-citation
Metadata
- Authors
- Elsherif, M., Hassan, M. U., Yetisen, A. K., & Butt, H.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-03-12
- Volume
- 12
- Issue
- 3
- Pages
- 2283-2291
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2794162149
- Cited by
- 210
- References
- 7
- FWCI
- 7.10
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.