The DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Palladium Diselenide Long-Wavelength Infrared Photodetector with High Sensitivity and Stability
Open accessAbstract
A long-wavelength infrared photodetector based on two-dimensional materials working at room temperature would have wide applications in many aspects in remote sensing, thermal imaging, biomedical optics, and medical imaging. However, sub-bandgap light detection in graphene and black phosphorus has been a long-standing scientific challenge because of their low photoresponsivity, instability in the air, and high dark current. In this study, we report a highly sensitive, air-stable, and operable long-wavelength infrared photodetector at room temperature based on PdSe 2 phototransistors and their heterostructure. A high photoresponsivity of ∼42.1 AW –1 (at 10.6 μm) was demonstrated, which is an order of magnitude higher than the current record of platinum diselenide. Moreover, the dark current and noise power density were suppressed effectively by fabricating a van der Waals heterostructure. This work fundamentally contributes to establishing long-wavelength infrared detection by PdSe 2 at the forefront of long-IR two-dimensional-materials-based photonics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Generalized Gradient Approximation Made Simple
Perdew, J. P., Burke, K., & Ernzerhof, M. (1996) · Physical Review Letters · doi:10.1103/physrevlett.77.3865 · Cited by 215,824
Efficient iterative schemes for ab initio total-energy calculations using a plane-wave basis set
Kresse, G., & Furthmüller, J. (1996) · Physical Review B · doi:10.1103/physrevb.54.11169 · Cited by 123,652
Ab initio molecular dynamics for liquid metals
Kresse, G., & Hafner, J. (1993) · Physical Review B · doi:10.1103/physrevb.47.558 · Cited by 45,727
Emerging Photoluminescence in Monolayer MoS2
Splendiani, A., Sun, L., Zhang, Y., Li, T., Kim, J., Chim, C.-Y., Galli, G., & Wang, F. (2010) · Nano Letters · doi:10.1021/nl903868w · Cited by 9,501
Fine Structure Constant Defines Visual Transparency of Graphene
Nair, R. R., Blake, P., Grigorenko, A. N., Novoselov, K. S., Booth, T. J., Stauber, T., Peres, N. M. R., & Geim, A. K. (2008) · Science · doi:10.1126/science.1156965 · Cited by 9,084
Black phosphorus field-effect transistors
Li, L., Yu, Y., Ye, G. J., Ge, Q., Ou, X., Wu, H., Feng, D., Chen, X. H., & Zhang, Y. (2014) · Nature Nanotechnology · doi:10.1038/nnano.2014.35 · Cited by 8,413
Self-citationVan der Waals Density Functional for General Geometries
Dion, M., Rydberg, H., Schröder, E., Langreth, D. C., & Lundqvist, B. I. (2004) · Physical Review Letters · doi:10.1103/physrevlett.92.246401 · Cited by 5,622
High-mobility transport anisotropy and linear dichroism in few-layer black phosphorus
Qiao, J., Kong, X., Hu, Z.-X., Yang, F., & Ji, W. (2014) · Nature Communications · doi:10.1038/ncomms5475 · Cited by 4,442
High Performance Multilayer MoS2 Transistors with Scandium Contacts
Das, S., Chen, H.-Y., Penumatcha, A. V., & Appenzeller, J. (2013) · Nano Letters · doi:10.1021/nl303583v · Cited by 2,428
Layer-controlled band gap and anisotropic excitons in few-layer black phosphorus
Tran, V., Soklaski, R., Liang, Y., & Yang, L. (2014) · Physical Review B · doi:10.1103/physrevb.89.235319 · Cited by 2,337
Cited by
Pham, P. V., Bodepudi, S. C., Shehzad, K., Liu, Y., Xu, Y., Yu, B., & Duan, X. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00735 · Cited by 708
Liang, S., Cheng, B., Cui, X., & Miao, F. (2020) · Advanced Materials · doi:10.1002/adma.201903800 · Cited by 537
Stable mid-infrared polarization imaging based on quasi-2D tellurium at room temperature
Tong, L., Huang, X., Wang, P., Ye, L., Peng, M., An, L., Sun, Q., Zhang, Y., Yang, G., Li, Z., et al. (2020) · Nature Communications · doi:10.1038/s41467-020-16125-8 · Cited by 485
Self-citationZeng, L., Chen, Q., Zhang, Z., Wu, D., Yuan, H., Li, Y., Qarony, W., Lau, S. P., Luo, L., & Tsang, Y. H. (2019) · Advanced Science · doi:10.1002/advs.201901134 · Cited by 465
Wu, D., Guo, C., Zeng, L., Ren, X., Shi, Z., Wen, L., Chen, Q., Zhang, M., Li, X. J., Shan, C.-X., et al. (2023) · Light: Science & Applications · doi:10.1038/s41377-022-01047-5 · Cited by 404
Metadata
- Authors
- Long, M., Wang, Y., Wang, P., Zhou, X., Xia, H., Luo, C., Huang, S., Zhang, G., Yan, H., Fan, Z., Wu, X., Chen, X., Lu, W., & Hu, W.
- Venue
- ACS Nano
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-02-06
- Volume
- 13
- Issue
- 2
- Pages
- 2511-2519
- ISSN
- 1936-0851 (ISSN-L)
- 1936-086X
- OpenAlex
- W2913750145
- Cited by
- 309
- References
- 49
- FWCI
- 16.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Palladium Diselenide Long-Wavelength Infrared Photodetector with High Sensitivity and Stability. https://app.cochat.ai/papers/10.1021/acsnano.8b09476
- The paper
- Long, M., Wang, Y., Wang, P., Zhou, X., Xia, H., Luo, C., Huang, S., Zhang, G., Yan, H., Fan, Z., Wu, X., Chen, X., Lu, W., & Hu, W. (2019). Palladium Diselenide Long-Wavelength Infrared Photodetector with High Sensitivity and Stability. ACS Nano. https://doi.org/10.1021/acsnano.8b09476
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.