CoChat

Ultrafast Photodetector by Integrating Perovskite Directly on Silicon Wafer

Geng, Xiangshun, Wang, Fangwei, Tian, He, Feng, Qixin, Zhang, Hainan, Liang, Renrong, Shen, Yang, Ju, Zhenyi, Gou, Guang-Yang, Deng, Ningqin, Li, Yu-tao, Ren, Jun, Xie, Dan, Yang, Yi, Ren, Tian-Ling · 2020 · ACS Nano

The DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.

Abstract

Single-crystal (SC) perovskite is currently a promising material due to its high quantum efficiency and long diffusion length. However, the reported perovskite photodetection range (<800 nm) and response time (>10 μs) are still limited. Here, to promote the development of perovskite-integrated optoelectronic devices, this work demonstrates wider photodetection range and shorter response time perovskite photodetector by integrating the SC CH 3 NH 3 PbBr 3 (MAPbBr 3 ) perovskite on silicon (Si). The Si/MAPbBr 3 heterojunction photodetector with an improved interface exhibits high-speed, broad-spectrum, and long-term stability performances. To the best of our knowledge, the measured detectable spectrum (405–1064 nm) largely expands the widest response range reported in previous perovskite-based photodetectors. In addition, the rise time is as fast as 520 ns, which is comparable to that of commercial germanium photodetectors. Moreover, the Si/MAPbBr 3 device can maintain excellent photocurrent performance for up to 3 months. Furthermore, typical gray scale face imaging is realized by scanning the Si/MAPbBr 3 single-pixel photodetector. This work using an ultrafast photodetector by directly integrating perovskite on Si can promote advances in next-generation integrated optoelectronic technology.

Overview

Integrity signals

Registry

Crossref · 10.1021/acsnano.9b06345

Cites

54 of 54 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 54 references

Research works printed but not linked: 1

  1. 10.1063/1.4971772 · DOI · Paper page

Cited by

Metadata

Authors
Geng, X., Wang, F., Tian, H., Feng, Q., Zhang, H., Liang, R., Shen, Y., Ju, Z., Gou, G.-Y., Deng, N., Li, Y.-T., Ren, J., Xie, D., Yang, Y., & Ren, T.-L.
Affiliations
  • Institute of Microelectronics (CN)
  • Tsinghua University (CN)
  • Institute of Microelectronics and Beijing National Research Center for Information Science and Technology (BNRist), Tsinghua University, Beijing 100084, China
Corresponding author
  • Tian, He
  • Liang, Renrong
  • Yang, Yi
  • Ren, Tian-Ling
Venue
ACS Nano
Published
2020-02-06
Volume
14
Issue
3
Pages
2860-2868
ISSN
  • 1936-0851 (ISSN-L)
  • 1936-086X
OpenAlex
W3004497030
Cited by
136
References
54
Citations by year
2026: 11 · 2025: 14 · 2024: 27 · 2023: 21 · 2022: 32 · 2021: 21 · 2020: 10
FWCI
7.21
Type
journal article
Language
en
Open access
closed
Locations
  • ACS Nano (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • Ministry of Science and Technology of the People's Republic of China (2015CB352101, 2016YFA0200300, 2016YFA0200400)
  • Ministry of Agriculture of the People's Republic of China (201303107)
  • Tsinghua University (2014Z01006)
  • China Academy of Space Technology (2018QNRC001)
  • National Natural Science Foundation (51861145202, 61434001, 61574083, 61874065)
  • Shenzhen Science and Technology Program (JCYJ20150831192224146)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Perovskite Materials and Applications
  • Physical Sciences › Materials Science › Materials Chemistry › 2D Materials and Applications
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Semiconductor Detectors and Materials
Keywords
perovskite photodetectors, MAPbBr3, perovskite single crystals, ultrafast response time, long-term device stability, single-pixel imaging, integrated optoelectronics

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.