Prospects of Surface-Enhanced Raman Spectroscopy for Biomarker Monitoring toward Precision Medicine
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Future precision medicine will be undoubtedly sustained by the detection of validated biomarkers that enable a precise classification of patients based on their predicted disease risk, prognosis, and response to a specific treatment. Up to now, genomics, transcriptomics, and immunohistochemistry have been the main clinically amenable tools at hand for identifying key diagnostic, prognostic, and predictive biomarkers. However, other molecular strategies, including metabolomics, are still in their infancy and require the development of new biomarker detection technologies, toward routine implementation into clinical diagnosis. In this context, surface-enhanced Raman scattering (SERS) spectroscopy has been recognized as a promising technology for clinical monitoring thanks to its high sensitivity and label-free operation, which should help accelerate the discovery of biomarkers and their corresponding screening in a simpler, faster, and less-expensive manner. Many studies have demonstrated the excellent performance of SERS in biomedical applications. However, such studies have also revealed several variables that should be considered for accurate SERS monitoring, in particular, when the signal is collected from biological sources (tissues, cells or biofluids). This Perspective is aimed at piecing together the puzzle of SERS in biomarker monitoring, with a view on future challenges and implications. We address the most relevant requirements of plasmonic substrates for biomedical applications, as well as the implementation of tools from artificial intelligence or biotechnology to guide the development of highly versatile sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Raman spectra of pyridine adsorbed at a silver electrode
Fleischmann, M., Hendra, P. J., & McQuillan, A. J. (1974) · Chemical Physics Letters · doi:10.1016/0009-2614(74)85388-1 · Cited by 7,172
Shin, H.-C., Roth, H. R., Gao, M., Lu, L., Xu, Z., Nogues, I., Yao, J., Mollura, D., & Summers, R. M. (2016) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2016.2528162 · Cited by 5,759
Surface raman spectroelectrochemistry
Jeanmaire, D. L., & Van Duyne, R. P. (1977) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/s0022-0728(77)80224-6 · Cited by 4,738
Plasmonics beyond the diffraction limit
Gramotnev, D. K., & Bozhevolnyi, S. I. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.282 · Cited by 3,903
Qiao, X., Su, B., Liu, C., Song, Q., Luo, D., Mo, G., & Wang, T. (2018) · Advanced Materials · doi:10.1002/adma.201702275 · Cited by 469
Guo, S., Popp, J., & Bocklitz, T. (2021) · Nature Protocols · doi:10.1038/s41596-021-00620-3 · Cited by 361
Shin, H., Jeong, H., Park, J., Hong, S., & Choi, Y. (2018) · ACS Sensors · doi:10.1021/acssensors.8b01047 · Cited by 246
Fornasaro, S., Alsamad, F., Baia, M., Batista de Carvalho, L. A. E., Beleites, C., Byrne, H. J., Chiadò, A., Chis, M., Chisanga, M., Daniel, A., et al. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05658 · Cited by 124
Thrift, W. J., & Ragan, R. (2019) · Analytical Chemistry · doi:10.1021/acs.analchem.9b03599 · Cited by 89
Cited by
Eremina, O. E., Czaja, A. T., Fernando, A., Aron, A., Eremin, D. B., & Zavaleta, C. (2022) · ACS Nano · doi:10.1021/acsnano.2c00353 · Cited by 88
Li, F., Chao, S., Wang, X., Hu, Z., Wang, D., Tang, C., Gong, Z., Zhang, H., & Fan, M. (2025) · Environmental Science & Technology · doi:10.1021/acs.est.5c07025 · Cited by 8
Metadata
- Authors
- Plou, J., Valera, P. S., García, I., de Albuquerque, C. D. L., Carracedo, A., & Liz-Marzán, L. M.
- Venue
- ACS Photonics
- Publisher
- American Chemical Society (ACS)
- Published
- 2022-02-02
- Volume
- 9
- Issue
- 2
- Pages
- 333-350
- ISSN
- 2330-4022 (ISSN-L)
- OpenAlex
- W4213100284
- Cited by
- 164
- References
- 9
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.