The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Electrochemosensor for Trace Analysis of Perfluorooctanesulfonate in Water Based on a Molecularly Imprinted Poly(o-phenylenediamine) Polymer
Open accessAbstract
This work is aimed at developing an electrochemical sensor for the sensitive and selective detection of trace levels of perfluorooctanesulfonate (PFOS) in water. Contamination of waters by perfluorinated alkyl substances (PFAS) is a problem of global concern due to their suspected toxicity and ability to bioaccumulate. PFOS is the perfluorinated compound of major concern, as it has the lowest suggested control concentrations. The sensor reported here is based on a gold electrode modified with a thin coating of a molecularly imprinted polymer (MIP), prepared by anodic electropolymerization of o-phenylenediamine (o-PD) in the presence of PFOS as the template. Activation of the sensor is achieved by template removal with suitable a solvent mixture. Voltammetry, a quartz crystal microbalance, scanning electron microscopy and elemental analysis were used to monitor the electropolymerization process, template removal, and binding of the analyte. Ferrocenecarboxylic acid (FcCOOH) has been exploited as an electrochemical probe able to generate analytically useful voltammetric signals by competing for the binding sites with PFOS, as the latter is not electroactive. The sensor has a low detection limit (0.04 nM), a satisfactory selectivity, and is reproducible and repeatable, giving analytical results in good agreement with those obtained by HPLC-MS/MS analyses.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perfluoroalkyl Acids: A Review of Monitoring and Toxicological Findings
Lau, C., Anitole, K., Hodes, C., Lai, D., Pfahles-Hutchens, A., & Seed, J. (2007) · Toxicological Sciences · doi:10.1093/toxsci/kfm128 · Cited by 2,620
Petrie, B., Barden, R., & Kasprzyk-Hordern, B. (2015) · Water Research · doi:10.1016/j.watres.2014.08.053 · Cited by 2,614
Vierke, L., Staude, C., Biegel-Engler, A., Drost, W., & Schulte, C. (2012) · Environmental Sciences Europe · doi:10.1186/2190-4715-24-16 · Cited by 222
Cited by
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D., & Kimura, S. Y. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05269 · Cited by 472
Lowdon, J. W., Diliën, H., Singla, P., Peeters, M., Cleij, T. J., van Grinsven, B., & Eersels, K. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128973 · Cited by 274
Metadata
- Authors
- Karimian, N., Stortini, A. M., Moretto, L. M., Costantino, C., Bogialli, S., & Ugo, P.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2018-06-18
- Volume
- 3
- Issue
- 7
- Pages
- 1291-1298
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2809516679
- Cited by
- 208
- References
- 3
- FWCI
- 6.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemosensor for Trace Analysis of Perfluorooctanesulfonate in Water Based on a Molecularly Imprinted Poly(o-phenylenediamine) Polymer. https://app.cochat.ai/papers/10.1021/acssensors.8b00154
- The paper
- Karimian, N., Stortini, A. M., Moretto, L. M., Costantino, C., Bogialli, S., & Ugo, P. (2018). Electrochemosensor for Trace Analysis of Perfluorooctanesulfonate in Water Based on a Molecularly Imprinted Poly(o-phenylenediamine) Polymer. ACS Sensors. https://doi.org/10.1021/acssensors.8b00154
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.