The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Cellulose Fibers Enable Near-Zero-Cost Electrical Sensing of Water-Soluble Gases
Open accessAbstract
Abstract We report an entirely new class of printed electrical gas sensors that are produced at near “zero cost”. This technology exploits the intrinsic hygroscopic properties of cellulose fibers within paper; although it feels and looks dry, paper contains substantial amount of moisture, adsorbed from the environment, enabling the use of wet chemical methods for sensing without manually adding water to the substrate. The sensors exhibit high sensitivity to water-soluble gases (e.g., lower limit of detection for NH3 < 200 parts-per-billion) with a fast and reversible response. The sensors show comparable or better performance (especially at high relative humidity) than most commercial ammonia sensors at a fraction of their price (<$0.02 per sensor). We demonstrate that the sensors proposed can be integrated into food packaging to monitor freshness (to reduce food waste and plastic pollution) or implemented into near-field-communication tags to function as wireless, battery-less gas sensors that can be interrogated with smartphones.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Paper‐Based Electrical Respiration Sensor
Güder, F., Ainla, A., Redston, J., Mosadegh, B., Glavan, A., Martin, T. J., & Whitesides, G. M. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201511805 · Cited by 472
Self-citation
Cited by
Paper-Based Sensors for Gas, Humidity, and Strain Detections: A Review
Tai, H., Duan, Z., Wang, Y., Wang, S., & Jiang, Y. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c06435 · Cited by 441
Guo, L., Wang, T., Wu, Z., Wang, J., Wang, M., Cui, Z., Ji, S., Cai, J., Xu, C., & Chen, X. (2020) · Advanced Materials · doi:10.1002/adma.202004805 · Cited by 292
Chemiresistive Sensor Arrays for Gas/Volatile Organic Compounds Monitoring: A Review
Rath, R. J., Farajikhah, S., Oveissi, F., Dehghani, F., & Naficy, S. (2023) · Advanced Engineering Materials · doi:10.1002/adem.202200830 · Cited by 183
Self-citationRoom temperature ammonia gas sensor based on ionic conductive biomass hydrogels
Liu, L., Fei, T., Guan, X., Lin, X., Zhao, H., & Zhang, T. (2020) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.128318 · Cited by 69
Metadata
- Authors
- Barandun, G., Soprani, M., Naficy, S., Grell, M., Kasimatis, M., Chiu, K. L., Ponzoni, A., & Güder, F.
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-05-08
- Volume
- 4
- Issue
- 6
- Pages
- 1662-1669
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2944390192
- Cited by
- 181
- References
- 1
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cellulose Fibers Enable Near-Zero-Cost Electrical Sensing of Water-Soluble Gases. https://app.cochat.ai/papers/10.1021/acssensors.9b00555
- The paper
- Barandun, G., Soprani, M., Naficy, S., Grell, M., Kasimatis, M., Chiu, K. L., Ponzoni, A., & Güder, F. (2019). Cellulose Fibers Enable Near-Zero-Cost Electrical Sensing of Water-Soluble Gases. ACS Sensors. https://doi.org/10.1021/acssensors.9b00555
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.