Natural Perspiration Sampling and in Situ Electrochemical Analysis with Hydrogel Micropatches for User-Identifiable and Wireless Chemo/Biosensing
Open accessThe DOI matches its Crossref record; 42 of the 43 references it cites were found in a registry or an index.
Abstract
Recent advances in microelectronics, microfluidics, and electrochemical sensing platforms have enabled the development of an emerging class of fully integrated personal health monitoring devices that exploit sweat to noninvasively access biomarker information. Despite such advances, effective sweat sampling remains a significant challenge for reliable biomarker analysis, with many existing methods requiring active stimulation (e.g., iontophoresis, exercise, heat). Natural perspiration offers a suitable alternative as sweat can be collected with minimal effort on the part of the user. To leverage this phenomenon, we devised a thin hydrogel micropatch (THMP), which simultaneously serves as an interface for sweat sampling and a medium for electrochemical sensing. To characterize the performance of the THMP, caffeine and lactate were selected as two representative target molecules. We demonstrated the suitability of the sampling method to track metabolic patterns, as well as to render sample-to-answer biomarker data for personal monitoring (through coupling with an electrochemical sensing system). To inform its potential application, this biomarker sampling and sensing system is incorporated within a distributed terminal-based sensing network, which uniquely capitalizes on the fingertip as a site for simultaneous biomarker data sampling and user identification.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“A few platforms have targeted low nL min−1 cm−2 rates, but have failed to enable continuous analysis and, critically, accurate measurement of resting sweat rate24,25.”
From A wearable patch for continuous analysis of thermoregulatory sweat at rest (2021) · cites this paper as [24]
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Self-citationWearable biosensors for healthcare monitoring
Kim, J., Campbell, A. S., de Ávila, B. E.-F., & Wang, J. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0045-y · Cited by 3,373
Lee, H., Choi, T. K., Lee, Y. B., Cho, H. R., Ghaffari, R., Wang, L., Choi, H. J., Chung, T. D., Lu, N., Hyeon, T., et al. (2016) · Nature Nanotechnology · doi:10.1038/nnano.2016.38 · Cited by 1,802
Bariya, M., Nyein, H. Y. Y., & Javey, A. (2018) · Nature Electronics · doi:10.1038/s41928-018-0043-y · Cited by 1,486
Wearable sensors: modalities, challenges, and prospects
Heikenfeld, J., Jajack, A., Rogers, J., Gutruf, P., Tian, L., Pan, T., Li, R., Khine, M., Kim, J., Wang, J., et al. (2018) · Lab on a Chip · doi:10.1039/c7lc00914c · Cited by 1,434
A soft, wearable microfluidic device for the capture, storage, and colorimetric sensing of sweat
Koh, A., Kang, D., Xue, Y., Lee, S., Pielak, R. M., Kim, J., Hwang, T., Min, S., Banks, A., Bastien, P., et al. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf2593 · Cited by 1,308
Caffeine Therapy for Apnea of Prematurity
Schmidt, B., Roberts, R. S., Davis, P., Doyle, L. W., Barrington, K. J., Ohlsson, A., Solimano, A., & Tin, W. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa054065 · Cited by 1,208
Electrochemical Tattoo Biosensors for Real-Time Noninvasive Lactate Monitoring in Human Perspiration
Jia, W., Bandodkar, A. J., Valdés-Ramírez, G., Windmiller, J. R., Yang, Z., Ramírez, J., Chan, G., & Wang, J. (2013) · Analytical Chemistry · doi:10.1021/ac401573r · Cited by 862
Emaminejad, S., Gao, W., Wu, E., Davies, Z. A., Yin Yin Nyein, H., Challa, S., Ryan, S. P., Fahad, H. M., Chen, K., Shahpar, Z., et al. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1701740114 · Cited by 839
Self-citationAccessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Cited by
Items 101–115 of 115
Shen, H., Liu, S., Liu, M., Liu, Y., Wen, F., Wang, M., Wang, Y., Gao, Q., Li, L., Zhou, D., et al. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00535-7 · Cited by 3
Recent advances in wearable sensor technology for sweat analysis
Jacob, J., Niranjan, D. B., Sharma, A., Jayakrishnan, S., Jose, R. C., Medikonda, J., Peter, M., & Namboothiri, P. K. (2026) · Discover Applied Sciences · doi:10.1007/s42452-026-08404-8 · Cited by 3
Saha, T., Moonla, C., Nandhakumar, P., Ji, G., Fishman, H. E., Jiang, X., Ding, S., Sabbagh, B., & Wang, J. (2026) · Matter · doi:10.1016/j.matt.2026.102967 · Cited by 1
Some of Our Favorite Papers from the First 10 Years of ACS Sensors
Gooding, J. J. (2025) · ACS Sensors · doi:10.1021/acssensors.4c03746 · Cited by 1
Fabrication and Application of Flexible Sensors
da Costa, T. H. (2020) · Louisiana State University · doi:10.31390/gradschool_dissertations.5356
Wireless and Wearable Biomarker Analysis
Lin, S., Wang, B., Shih, R. M., & Emaminejad, S. (2021) · Wiley eBooks · doi:10.1002/9781119683285.ch14
Self-citationNagamine, K., Sekine, T., & Tokito, S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822548-6.00077-7
Wet Interface Technologies for Wearable Sweat Sensors
Nagamine, K., & Tokito, S. (2024) · Springer eBooks · doi:10.1007/978-981-99-8122-9_10
Hydrogel‐Based Sensing for Living Biosystems
Zhao, Y., Pan, Y., & Yu, P. (2024) · Wiley eBooks · doi:10.1002/9780470027318.a9815
Self-citationSmart wearable sensors for healthcare application
Chu, Z., Zhou, Y., Li, S., Xu, Q., Su, M., & Pan, L. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00030-2
Development of Biosensors for Medical Applications
Bauer, M. (2024) · University of Regensburg Publication Server (University of Regensburg) · doi:10.5283/epub.52690
Nawazish, H., Shen, C., Wang, R., Lu, J., 程杰顺, Wang, H., Cai, K., & Xu, B. (2026) · Food Research International · doi:10.1016/j.foodres.2026.119901
Painless Biosensing for Non‐Invasive Health Monitoring: Advances, Platforms and Future Directions
Alam, A., Gull, F., Hameed, M., Iqbal, I., Naz, S., Noor, H., Aslam, A., Younis, S., Vit, V., Mehmood, M. A., et al. (2026) · Electrochemical Science Advances · doi:10.1002/elsa.70041
Smart Textile Systems as Dynamic Platform for Human Hydration Monitoring
Zou, X., Zhang, Y., Forrester, S., & Xu, L. (2026) · Biomedical Materials & Devices · doi:10.1007/s44174-026-00780-4
Jeong, J., & Jung, D. (2026) · Gels · doi:10.3390/gels12100883
Metadata
- Authors
- Lin, S., Wang, B., Zhao, Y., Shih, R., Cheng, X., Yu, W., Hojaiji, H., Lin, H., Hoffman, C., Ly, D., Tan, J., Chen, Y., Di Carlo, D., Milla, C., & Emaminejad, S.
- Affiliations
- University of California, Los Angeles (US)
- University of California , , , , , ,
- Stanford Medicine (US)
- Corresponding author
- Emaminejad, Sam
- ORCID
- Venue
- ACS Sensors
- Publisher
- American Chemical Society (ACS)
- Published
- 2019-12-01
- Volume
- 5
- Issue
- 1
- Pages
- 93-102
- ISSN
- 2379-3694 (ISSN-L)
- OpenAlex
- W2991409526
- Semantic Scholar
- 68edd9120a2cdcad8ca87a80a44f40fbfbfc1e94
- Cited by
- 114
- References
- 43
- Citations by year
- 2026: 11 · 2025: 20 · 2024: 18 · 2023: 15 · 2022: 19 · 2021: 18 · 2020: 13
- FWCI
- 4.41
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- ACS Sensors (publishedVersion, other-oa)
- PubMed (publishedVersion)
- Funders
- Division of Information and Intelligent Systems (1722972)
- Pharmaceutical Research and Manufacturers of America Foundation (NA)
- Henry Samueli School of Engineering and Applied Science, University of California, Los Angeles (NA)
- Stanford Genome Technology Center (NA)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Chemistry › Analytical Chemistry › Electrochemical sensors and biosensors
- Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
- Keywords
- sweat sampling, electrochemical biosensing, wireless biosensing, personal health monitoring, caffeine detection, lactate detection, metabolic biomarkers, user identification, fingertip sensing, distributed sensing networks
- MeSH terms
- Wearable Electronic Devices, Humans, Sweat, Biosensing Techniques, Hydrogels, Electrochemical Techniques
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.