The DOI matches its Crossref record.
Thread as a Matrix for Biomedical Assays
Abstract
This paper describes the use of thread as a matrix for the fabrication of diagnostic assay systems. The kinds of thread used for this study are inexpensive, broadly available, and lightweight; some of them are already familiar materials in healthcare. Fluids wick along these threads by capillary action; no external power source is necessary for pumping. This paper demonstrates three designs for diagnostic assays that use different characteristics of the thread. The first two designs-the "woven array" and the "branching design"-take advantage of the ease with which thread can be woven on a loom to generate fluidic pathways that enable multiple assays to be performed in parallel. The third design-the "sewn array"-takes advantage of the ease with which thread can be sewn through a hydrophobic polymer sheet to incorporate assays into bandages, diapers and similar systems. These designs lead to microfluidic devices that may be useful in performing simple colorimetric assays that require qualitative results. We demonstrate the function of thread-based microfluidic devices in the context of five different colorimetric assays: detection of ketones, nitrite, protein, and glucose in artificial urine, and detection of alkaline phosphatase in artificial plasma.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Paper-based microfluidic point-of-care diagnostic devices
Yetisen, A. K., Akram, M. S., & Lowe, C. R. (2013) · Lab on a Chip · doi:10.1039/c3lc50169h · Cited by 1,943
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
A perspective on paper-based microfluidics: Current status and future trends
Li, X., Ballerini, D. R., & Shen, W. (2012) · Biomicrofluidics · doi:10.1063/1.3687398 · Cited by 813
Vella, S. J., Beattie, P., Cademartiri, R., Laromaine, A., Martinez, A. W., Phillips, S. T., Mirica, K. A., & Whitesides, G. M. (2012) · Analytical Chemistry · doi:10.1021/ac203434x · Cited by 333
Self-citationMicrofluidic Point-of-Care Testing: Commercial Landscape and Future Directions
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.602659 · Cited by 262
Metadata
- Authors
- Reches, M., Mirica, K. A., Dasgupta, R., Dickey, M. D., Butte, M. J., & Whitesides, G. M.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-05-24
- Volume
- 2
- Issue
- 6
- Pages
- 1722-1728
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2155397056
- Cited by
- 250
- References
- 0
- FWCI
- 8.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thread as a Matrix for Biomedical Assays. https://app.cochat.ai/papers/10.1021/am1002266
- The paper
- Reches, M., Mirica, K. A., Dasgupta, R., Dickey, M. D., Butte, M. J., & Whitesides, G. M. (2010). Thread as a Matrix for Biomedical Assays. ACS Applied Materials & Interfaces. https://doi.org/10.1021/am1002266
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.