Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 262

The DOI matches its Crossref record; 81 of the 81 references it cites were found in a registry or an index.

Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions

Open access
Sachdeva, Shivangi, Davis, Ronald W., Saha, Amit K.·2021·Frontiers in Bioengineering and Biotechnology

Abstract

Point-of-care testing (POCT) allows physicians to detect and diagnose diseases at or near the patient site, faster than conventional lab-based testing. The importance of POCT is considerably amplified in the trying times of the COVID-19 pandemic. Numerous point-of-care tests and diagnostic devices are available in the market including, but not limited to, glucose monitoring, pregnancy and infertility testing, infectious disease testing, cholesterol testing and cardiac markers. Integrating microfluidics in POCT allows fluid manipulation and detection in a singular device with minimal sample requirements. This review presents an overview of two technologies - (a.) Lateral Flow Assay (LFA) and (b.) Nucleic Acid Amplification - upon which a large chunk of microfluidic POCT diagnostics is based, some of their applications, and commercially available products. Apart from this, we also delve into other microfluidic-based diagnostics that currently dominate the in-vitro diagnostic (IVD) market, current testing landscape for COVID-19 and prospects of microfluidics in next generation diagnostics.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3389/fbioe.2020.602659

Cites

81 of 81 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 81 references

Research works printed but not linked: 24

  1. Ballard, 2018, Nucleic acid quantification in the field, Nat. Biomed. Eng, 2, 629, 10.1038/s41551-018-0292-0 · doi:10.1038/s41551-018-0292-0
  2. Caetano, 2018, Combination of electrochemical biosensor and textile threads: a microfluidic device for phenol determination in tap water, Biosens. Bioelectron., 99, 382, 10.1016/j.bios.2017.07.070 · doi:10.1016/j.bios.2017.07.070
  3. 2020, Coronavirus Disease 2019 (COVID-19) Frequently Asked Questions
  4. Cox, 2015, Rapid detection of Bacillus anthracis by γ phage amplification and lateral flow immunochromatography, J. Microbiol. Methods, 118, 51, 10.1016/j.mimet.2015.08.011 · doi:10.1016/j.mimet.2015.08.011
  5. 2018, In Vitro Diagnostics: Technologies and Global Markets in M2 Presswire
  6. Gessler, 2007, Evaluation of lateral flow assays for the detection of botulinum neurotoxin type A and their application in laboratory diagnosis of botulism, Diagn. Microbiol. Infect. Dis., 57, 243, 10.1016/j.diagmicrobio.2006.07.017 · doi:10.1016/j.diagmicrobio.2006.07.017
  7. Ghosh, 2020, A new microchannel capillary flow assay (MCFA) platform with lyophilized chemiluminescence reagents for a smartphone-based POCT detecting malaria, Microsyst. Nanoeng, 6, 5, 10.1038/s41378-019-0108-8 · doi:10.1038/s41378-019-0108-8
  8. Haushalter, 2016, Multiplex flow assays, ACS Omega, 1, 586, 10.1021/acsomega.6b00188 · doi:10.1021/acsomega.6b00188
  9. Hsu, 2018, Rapid and sensitive detection of Yersinia pestis by lateral-flow assay in simulated clinical samples, BMC Infect. Dis, 18, 402, 10.1186/s12879-018-3315-2 · doi:10.1186/s12879-018-3315-2
  10. Li, 2016, Multiplexed lateral flow biosensors: technological advances for radically improving point-of-care diagnoses, Biosens. Bioelectron, 83, 177, 10.1016/j.bios.2016.04.021 · doi:10.1016/j.bios.2016.04.021
  11. Mahmoudi, 2019, Recent advancements in structural improvements of lateral flow assays towards point-of-care testing, TrAC Trends Analy. Chem, 116, 13, 10.1016/j.trac.2019.04.016 · doi:10.1016/j.trac.2019.04.016
  12. Müller, 1949, Automatic paper chromatography, Analy. Chem, 21, 1123, 10.1021/ac60033a032 · doi:10.1021/ac60033a032
  13. Naeimirad, 2019, Microfluidic through fibrous structures: recent developments and future trends, Mater. Design Process. Commun, 1, e78, 10.1002/mdp2.78 · doi:10.1002/mdp2.78
  14. Ndlovu, 2020, Diagnostic performance and usability of the VISITECT CD4 semi-quantitative test for advanced HIV disease screening, PLoS ONE, 15, e0230453, 10.1371/journal.pone.0230453 · doi:10.1371/journal.pone.0230453
  15. Opollo, 2018, Field evaluation of near point of care Cepheid GeneXpert HIV-1 qual for early infant diagnosis, PLoS ONE, 13, e0209778, 10.1371/journal.pone.0209778 · doi:10.1371/journal.pone.0209778
  16. Parida, 2020, Advance detection technologies for select biothreat agents, 83, 10.1016/B978-0-12-812026-2.00005-0 · doi:10.1016/b978-0-12-812026-2.00005-0
  17. Pillai, 2020, Comprehensive laboratory evaluation of a specific lateral flow assay for the presumptive identification of francisella tularensis in suspicious white powders and aerosol samples, Health Secur, 18, 83, 10.1089/hs.2019.0151 · doi:10.1089/hs.2019.0151
  18. Qamar, 2019, Evolution of wax-on-plastic microfluidics for sub-microliter flow dynamics and its application in distance-based assay, Microfluidics Nanofluidics, 23, 81, 10.1007/s10404-019-2249-3 · doi:10.1007/s10404-019-2249-3
  19. Reid, 2020, Application of aptamers as molecular recognition elements in lateral flow assays, Analy. Biochem, 593, 113574, 10.1016/j.ab.2020.113574 · doi:10.1016/j.ab.2020.113574
  20. Saha, Cholesterol regulates monocyte rolling through cd44 distribution, Biophys. J, 112, 1481, 10.1016/j.bpj.2017.02.021 · doi:10.1016/j.bpj.2017.02.021
  21. Sahoo, 2016, Loop mediated isothermal amplification: an innovative gene amplification technique for animal diseases, Vet. World, 9, 465, 10.14202/vetworld.2016.465-469 · doi:10.14202/vetworld.2016.465-469
  22. Wang, 2018, Lateral flow immunoassay integrated with competitive and sandwich models for the detection of aflatoxin M1 and Escherichia coli O157:H7 in milk, J. Dairy Sci., 101, 8767, 10.3168/jds.2018-14655 · doi:10.3168/jds.2018-14655
  23. Wang, 2012, Paper-based chemiluminescence ELISA: lab-on-paper based on chitosan modified paper device and wax-screen-printing, Biosens. Bioelectron., 31, 212, 10.1016/j.bios.2011.10.019 · doi:10.1016/j.bios.2011.10.019
  24. Yew, 2018, Electrospin-coating of nitrocellulose membrane enhances sensitivity in nucleic acid-based lateral flow assay, Anal. Chim. Acta, 1009, 81, 10.1016/j.aca.2018.01.016 · doi:10.1016/j.aca.2018.01.016

Cited by

See all 262

Metadata

Authors
Sachdeva, S., Davis, R. W., & Saha, A. K.
Venue
Frontiers in Bioengineering and Biotechnology
Published
2021-01-15
Volume
8
Pages
602659-602659
ISSN
2296-4185 (ISSN-L)
OpenAlex
W3119601322
Cited by
262
References
81
FWCI
13.58
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions. https://app.cochat.ai/papers/10.3389/fbioe.2020.602659
The paper
Sachdeva, S., Davis, R. W., & Saha, A. K. (2021). Microfluidic Point-of-Care Testing: Commercial Landscape and Future Directions. Frontiers in Bioengineering and Biotechnology. https://doi.org/10.3389/fbioe.2020.602659

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.