The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Facile Hydrothermal Synthesis and Surface Functionalization of Polyethyleneimine-Coated Iron Oxide Nanoparticles for Biomedical Applications
Abstract
We report the facile hydrothermal synthesis and surface functionalization of branched polyethyleneimine (PEI)-coated iron oxide nanoparticles (Fe3O4-PEI NPs) for biomedical applications. In this study, Fe3O4-PEI NPs were synthesized via a one-pot hydrothermal method in the presence of PEI. The formed Fe3O4-PEI NPs with primary amine groups on the surface were able to be further functionalized with polyethylene glycol (PEG), acetic anhydride, and succinic anhydride, respectively. The formed pristine and functionalized Fe3O4-PEI NPs were characterized via different techniques. We showed that the sizes of the Fe3O4-PEI NPs were able to be controlled by varying the mass ratio of Fe(II) salt and PEI. In addition, the formed Fe3O4-PEI NPs with different surface functionalities had good water dispersibility, colloidal stability, and relatively high R2 relaxivity (130-160 1/(mM·s)). Cell viability assay data revealed that the surface PEGylation and acylation of Fe3O4-PEI NPs rendered them with good biocompatibility in the given concentration range, while the pristine aminated Fe3O4-PEI NPs started to display slight toxicity at the concentration of 50 μg/mL. Importantly, macrophage cellular uptake results demonstrated that both PEGylation and acetylation of Fe3O4-PEI NPs were able to significantly reduce the nonspecific macrophage uptake, likely rendering the particles with prolonged circulation time. With the proven hemocompatibility and rich amine conjugation chemistry, the Fe3O4-PEI NPs with different surface functionalities may be applied for various biomedical applications, especially for magnetic resonance imaging and therapy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
PEGylated nanoparticles for biological and pharmaceutical applications
Otsuka, H., Nagasaki, Y., & Kataoka, K. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00226-0 · Cited by 1,588
The Impact of PEGylation on Biological Therapies
Veronese, F. M., & Mero, A. (2008) · BioDrugs · doi:10.2165/00063030-200822050-00004 · Cited by 1,034
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Effective drug delivery by PEGylated drug conjugates
Greenwald, R. B., Choe, Y. H., McGuire, J., & Conover, C. D. (2003) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(02)00180-1 · Cited by 869
Neu, M., Fischer, D., & Kissel, T. (2005) · The Journal of Gene Medicine · doi:10.1002/jgm.773 · Cited by 866
Xie, J., Xu, C., Kohler, N., Hou, Y., & Sun, S. (2007) · Advanced Materials · doi:10.1002/adma.200701975 · Cited by 686
Hydrothermal Synthesis of Monodisperse Magnetite Nanoparticles
Daou, T. J., Pourroy, G., Bégin-Colin, S., Grenèche, J. M., Ulhaq-Bouillet, C., Legaré, P., Bernhardt, P., Leuvrey, C., & Rogez, G. (2006) · Chemistry of Materials · doi:10.1021/cm060805r · Cited by 651
Cheng, L., Yang, K., Li, Y., Chen, J., Wang, C., Shao, M., Lee, S., & Liu, Z. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201101447 · Cited by 650
Villaraza, A. J. L., Bumb, A., & Brechbiel, M. W. (2010) · Chemical Reviews · doi:10.1021/cr900232t · Cited by 632
Chen, Y., Chen, H., Zeng, D., Tian, Y., Chen, F., Feng, J., & Shi, J. (2010) · ACS Nano · doi:10.1021/nn1015117 · Cited by 627
Cited by
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Surface modification of magnetic iron oxide nanoparticles
Zhu, N., Ji, H., Yu, P., Niu, J., Farooq, M. U., Akram, M. W., Udego, I. O., Li, H., & Niu, X. (2018) · Nanomaterials · doi:10.3390/nano8100810 · Cited by 569
Wu, W., Jiang, C. Z., & Roy, V. A. L. (2016) · Nanoscale · doi:10.1039/c6nr07542h · Cited by 417
Iron Oxide Nanoparticle Based Contrast Agents for Magnetic Resonance Imaging
Shen, Z., Wu, A., & Chen, X. (2017) · Molecular Pharmaceutics · doi:10.1021/acs.molpharmaceut.6b00839 · Cited by 328
Li, J., Zheng, L., Cai, H., Sun, W., Shen, M., Zhang, G., & Shi, X. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.07.070 · Cited by 271
Self-citation
Metadata
- Authors
- Cai, H., An, X., Cui, J., Li, J., Wen, S., Li, K., Shen, M., Zheng, L., Zhang, G., & Shi, X.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-02-19
- Volume
- 5
- Issue
- 5
- Pages
- 1722-1731
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2072081304
- Cited by
- 306
- References
- 41
- FWCI
- 16.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.