Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 207

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Silver Nanoparticles and Growth Factors Incorporated Hydroxyapatite Coatings on Metallic Implant Surfaces for Enhancement of Osteoinductivity and Antibacterial Properties

Xie, Chao-Ming, Lu, Xiong, Wang, Ke-Feng, Meng, Fan-Zhi, Jiang, Ou, Zhang, Hong-Ping, Zhi, Wei, Fang, Li-Ming · 2014 · ACS Applied Materials & Interfaces

Abstract

Research on incorporation of both growth factors and silver (Ag) into hydroxyapatite (HA) coatings on metallic implant surfaces for enhancing osteoinductivity and antibacterial properties is a challenging work. Generally, Ag nanoparticles are easy to agglomerate and lead to a large increase in local Ag concentration, which could potentially affect cell activity. On the other hand, growth factors immobilization requires mild processing conditions so as to maintain their activities. In this study, bone morphology protein-2 (BMP-2) and Ag nanoparticle contained HA coatings were prepared on Ti surfaces by combining electrochemical deposition (ED) of Ag and electrostatic immobilization of BMP-2. During the ED process, chitosan (CS) was selected as the stabilizing agent to chelate Ag ions and generate Ag nanoparticles that are uniformly distributed in the coatings. CS also reduces Ag toxicity while retaining its antibacterial activity. Afterwards, a BMP/heparin solution was absorbed on the CS/Ag/HA coatings. Consequently, BMP-2 was immobilized on the coatings by the electrostatic attraction between CS, heparin, and BMP-2. Sustained release of BMP-2 and Ag ions from HA coatings was successfully demonstrated for a long period. Results of antibacterial tests indicate that the CS/Ag/HA coatings have high antibacterial properties against both Staphylococcus epidermidis and Escherichia coli. Osteoblasts (OB) culture reveals that the CS/Ag/HA coatings exhibit good biocompatibility. Bone marrow stromal cells (BMSCs) culture indicates that the BMP/CS/Ag/HA coatings have good osteoinductivity and promote the differentiation of BMSCs. Ti bars with BMP/CS/Ag/HA coatings were implanted into the femur of rabbits to evaluate the osteoinductivity of the coatings. Results indicate that BMP/CS/Ag/HA coatings favor bone formation in vivo. In summary, this study presents a convenient and effective method for the incorporation of growth factors and antibacterial agents into HA coatings. This method can be utilized to modify a variety of metallic implant surfaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1021/am501428e

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Xie, C.-M., Lu, X., Wang, K.-F., Meng, F.-Z., Jiang, O., Zhang, H.-P., Zhi, W., & Fang, L.-M.
Venue
ACS Applied Materials & Interfaces
Published
2014-04-21
Volume
6
Issue
11
Pages
8580-8589
ISSN
  • 1944-8244 (ISSN-L)
  • 1944-8252
OpenAlex
W2335535029
Cited by
207
References
2
FWCI
9.60
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.