The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Highly Conductive and Flexible Silver Nanowire-Based Microelectrodes on Biocompatible Hydrogel
Abstract
We successfully fabricated silver nanowire (AgNW)-based microelectrodes on various substrates such as a glass and polydimethylsiloxane by using a photolithographic process for the first time. The AgNW-based microelectrodes exhibited excellent electrical conductivity and mechanical flexibility. We also demonstrated the direct transfer process of AgNW-based microelectrodes from a glass to a biocompatible polyacrylamide-based hydrogel. The AgNW-based microelectrodes on the biocompatible hydrogel showed excellent electrical performance. Furthermore, they showed great mechanical flexibility as well as superior stability under wet conditions. We anticipate that the AgNW-based microelectrodes on biocompatible hydrogel substrates can be a promising platform for realization of practical bioelectronics devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2012) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.09.010 · Cited by 3,396
Self-Assembled Graphene Hydrogel via a One-Step Hydrothermal Process
Xu, Y., Sheng, K., Li, C., & Shi, G. (2010) · ACS Nano · doi:10.1021/nn101187z · Cited by 3,251
Highly Stretchable and Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite
Amjadi, M., Pichitpajongkit, A., Lee, S., Ryu, S., & Park, I. (2014) · ACS Nano · doi:10.1021/nn501204t · Cited by 2,350
25th Anniversary Article: Engineering Hydrogels for Biofabrication
Malda, J., Visser, J., Melchels, F. P., Jüngst, T., Hennink, W. E., Dhert, W. J. A., Groll, J., & Hutmacher, D. W. (2013) · Advanced Materials · doi:10.1002/adma.201302042 · Cited by 1,901
Flexible and Stretchable Electronics for Biointegrated Devices
Kim, D.-H., Ghaffari, R., Lu, N., & Rogers, J. A. (2012) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071811-150018 · Cited by 749
Conducting Polymer Electrodes Printed on Hydrogel
Sekine, S., Ido, Y., Miyake, T., Nagamine, K., & Nishizawa, M. (2010) · Journal of the American Chemical Society · doi:10.1021/ja1062357 · Cited by 162
Cited by
Yuk, H., Lu, B., & Zhao, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00595h · Cited by 2,108
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Electrically conductive hydrogels for flexible energy storage systems
Zhang, W., Feng, P., Chen, J., Sun, Z., & Zhao, B. (2019) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2018.09.001 · Cited by 409
Conductive Hydrogels as Smart Materials for Flexible Electronic Devices
Rong, Q., Lei, W., & Liu, M. (2018) · Chemistry – A European Journal · doi:10.1002/chem.201801302 · Cited by 331
Multilayer Graphene Epidermal Electronic Skin
Qiao, Y., Wang, Y., Tian, H., Li, M., Jian, J., Wei, Y., Tian, Y., Wang, D.-Y., Pang, Y., Geng, X., et al. (2018) · ACS Nano · doi:10.1021/acsnano.8b02162 · Cited by 317
Biomedical Implants with Charge‐Transfer Monitoring and Regulating Abilities
Wang, D., Tan, J., Zhu, H., Mei, Y., & Liu, X. (2021) · Advanced Science · doi:10.1002/advs.202004393 · Cited by 49
Metadata
- Authors
- Ahn, Y., Lee, H., Lee, D., & Lee, Y.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2014-10-30
- Volume
- 6
- Issue
- 21
- Pages
- 18401-18407
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2325662299
- Cited by
- 181
- References
- 6
- FWCI
- 5.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.