Near-Infrared Phosphorescent Polymeric Nanomicelles: Efficient Optical Probes for Tumor Imaging and Detection
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
We report a formulation of near-infrared (near-IR) phosphorescent polymeric nanomicelles and their use for in vivo high-contrast optical imaging, targeting, and detection of tumors in small animals. Near-IR phosphorescent molecules of Pt(II)-tetraphenyltetranaphthoporphyrin (Pt(TPNP)) were found to maintain their near-IR phosphorescence properties when encapsulated into phospholipid nanomicelles. The prepared phosphorescent micelles are of approximately 100 nm size and are highly stable in aqueous suspensions. A large spectral separation between the Pt(TPNP) absorption, with a peak at approximately 700 nm, and its phosphorescence emission, with a peak at approximately 900 nm, allows a dramatic decrease in the level of background autofluorescence and scattered excitation light in the near-IR spectral range, where the signal from the phosphorescent probe is observed. In vivo animal imaging with subcutaneously xenografted tumor-bearing mice has resulted in high contrast optical images, indicating highly specific accumulation of the phosphorescent micelles into tumors. Using optical imaging with near-IR phosphorescent nanomicelles, detection of smaller, visually undetectable tumors has also been demonstrated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A clearer vision for in vivo imaging
Weissleder, R. (2001) · Nature Biotechnology · doi:10.1038/86684 · Cited by 3,839
Micellar Nanocarriers: Pharmaceutical Perspectives
Torchilin, V. P. (2006) · Pharmaceutical Research · doi:10.1007/s11095-006-9132-0 · Cited by 1,910
Multifunctional and stimuli-sensitive pharmaceutical nanocarriers
Torchilin, V. (2009) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2008.09.026 · Cited by 583
Nanoparticle PET-CT Imaging of Macrophages in Inflammatory Atherosclerosis
Nahrendorf, M., Zhang, H., Hembrador, S., Panizzi, P., Sosnovik, D. E., Aikawa, E., Libby, P., Swirski, F. K., & Weissleder, R. (2008) · Circulation · doi:10.1161/circulationaha.107.741181 · Cited by 559
Chen, H., Kim, S., Li, L., Wang, S., Park, K., & Cheng, J.-X. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707046105 · Cited by 394
Esmaeili, F., Ghahremani, M. H., Esmaeili, B., Khoshayand, M. R., Atyabi, F., & Dinarvand, R. (2008) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2007.07.038 · Cited by 159
Cited by
Photothermal therapy and photoacoustic imaging via nanotheranostics in fighting cancer
Liu, Y., Bhattarai, P., Dai, Z., & Chen, X. (2019) · Chemical Society Reviews · doi:10.1039/c8cs00618k · Cited by 2,904
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Self-citationPhosphorescent heavy-metal complexes for bioimaging
Zhao, Q., Huang, C., & Li, F. (2011) · Chemical Society Reviews · doi:10.1039/c0cs00114g · Cited by 1,260
Near-infrared fluorescence: application to in vivo molecular imaging
Hilderbrand, S. A., & Weissleder, R. (2010) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2009.09.029 · Cited by 1,023
Near-infrared phosphorescence: materials and applications
Xiang, H., Cheng, J., Ma, X., Zhou, X., & Chruma, J. J. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60029g · Cited by 720
Metadata
- Authors
- Kumar, R., Ohulchanskyy, T. Y., Roy, I., Gupta, S. K., Borek, C., Thompson, M. E., & Prasad, P. N.
- Venue
- ACS Applied Materials & Interfaces
- Publisher
- American Chemical Society (ACS)
- Published
- 2009-06-22
- Volume
- 1
- Issue
- 7
- Pages
- 1474-1481
- ISSN
- 1944-8244 (ISSN-L)
- 1944-8252
- OpenAlex
- W2053557650
- Cited by
- 92
- References
- 6
- FWCI
- 3.88
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.