Cited by 559Cardiac Imaging and DiagnosticsRadiopharmaceutical Chemistry and ApplicationsAtherosclerosis and Cardiovascular Diseases

Nanoparticle PET-CT Imaging of Macrophages in Inflammatory Atherosclerosis

Open access
Nahrendorf, Matthias, Zhang, Hanwen, Hembrador, Sheena, Panizzi, Peter, Sosnovik, David E., Aikawa, Elena, Libby, Peter, Swirski, Filip K. +1 more·2008·Circulation

Abstract

Background— Macrophages participate centrally in atherosclerosis, and macrophage markers (eg, CD68, MAC-3) correlate well with lesion severity and therapeutic modulation. On the basis of the avidity of lesional macrophages for polysaccharide-containing supramolecular structures such as nanoparticles, we have developed a new positron emission tomography (PET) agent with optimized pharmacokinetics to allow in vivo imaging at tracer concentrations. Methods and Results— A dextranated and DTPA-modified magnetofluorescent 20-nm nanoparticle was labeled with the PET tracer 64 Cu (1 mCi/0.1 mg nanoparticles) to yield a PET, magnetic resonance, and optically detectable imaging agent. Peak PET activity 24 hours after intravenous injection into mice deficient in apolipoprotein E with experimental atherosclerosis mapped to areas of high plaque load identified by computed tomography such as the aortic root and arch and correlated with magnetic resonance and optical imaging. Accumulated dose in apolipoprotein E–deficient aortas determined by gamma counting was 260% and in carotids 392% of respective wild-type organs ( P <0.05 both). Autoradiography of aortas demonstrated uptake of the agent into macrophage-rich atheromata identified by Oil Red O staining of lipid deposits. The novel nanoagent accumulated predominantly in macrophages as determined by fluorescence microscopy and flow cytometry of cells dissociated from aortas. Conclusions— This report establishes the capability of a novel trimodality nanoparticle to directly detect macrophages in atherosclerotic plaques. Advantages include improved sensitivity; direct correlation of PET signal with an established biomarker (CD68); ability to readily quantify the PET signal, perform whole-body vascular surveys, and spatially localize and follow the trireporter by microscopy; and clinical translatability of the agent given similarities to magnetic resonance imaging probes in clinical trials.

Integrity signals

Registry

Crossref · 10.1161/circulationaha.107.741181

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Nahrendorf et al. labelled iron oxide nanoparticles with 64Cu, showing accumulation in atherosclerotic arteries of APOE-knockout mice using PET-CT.

    “For example, Nahrendorf et al.148 labelled iron oxide nanoparticles with the radiolabelled PET tracer 64Cu, showing the accumulation of the nanoparticles in atherosclerotic arteries of APOE-knockout mice using PET–CT imaging (FIG. 6b).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Nahrendorf, M., Zhang, H., Hembrador, S., Panizzi, P., Sosnovik, D. E., Aikawa, E., Libby, P., Swirski, F. K., & Weissleder, R.
Affiliations
  • Brigham and Women's Hospital (US)
  • From the Center for Systems Biology, Massachusetts General Hospital and Harvard Medical School, Boston (M.N., R.W.); Center for Molecular Imaging Research, Massachusetts General Hospital and Harvard Medical School, Charlestown (M.N., H.Z., S.H., P.P., D.E.S., E.A., F.K.S., R.W.); Donald W. Reynolds Cardiovascular Clinical Research Center on Atherosclerosis at Harvard Medical School, Boston, Mass (M.N., E.A., P.L., R.W.); Department of Cardiology, Massachusetts General Hospital, Boston (D.E.S.); and...
Venue
Circulation
Published
2008-01-22
Volume
117
Issue
3
Pages
379-387
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2011809692
Cited by
559
References
32
Citations by year
2026: 3 · 2025: 5 · 2024: 17 · 2023: 15 · 2022: 33 · 2021: 15 · 2020: 24 · 2019: 17 · 2018: 25 · 2017: 30 · 2016: 31 · 2015: 30 · 2014: 40 · 2013: 33 · 2012: 55
FWCI
32.74
Type
journal article
Language
en
Open access
Locations
  • Circulation (publishedVersion)
  • PubMed (publishedVersion)
  • PubMed Central (acceptedVersion)
  • Digital Access to Scholarship at Harvard (DASH) (Harvard University) (submittedVersion, cc-by)
Funders
  • University of Washington
  • National Heart, Lung, and Blood Institute (U01HL080731, R01HL078641, R00HL094533)
  • National Cancer Institute (R24-CA-92782, R24CA092782)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiopharmaceutical Chemistry and Applications
  • Life Sciences › Immunology and Microbiology › Immunology › Atherosclerosis and Cardiovascular Diseases
Keywords
atherosclerosis, macrophages, positron emission tomography, nanoparticles, copper-64, CD68, ApoE-deficient mice, atherosclerotic plaque, multimodal imaging, magnetic resonance imaging, fluorescence imaging, nanoparticle pharmacokinetics
MeSH terms
CD68 Molecule, Animals, Apolipoproteins E, Copper Radioisotopes, Inflammation, Macrophages, Microscopy, Sensitivity and Specificity, Antigens, Differentiation, Myelomonocytic, Biomarkers, Antigens, CD, Positron-Emission Tomography, Atherosclerosis, Mice, Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review