CoChat

Simultaneous optical measurement of osmotic and diffusional water permeability in cells and liposomes

Ye, Rengao, Verkman, A. S. · 1989 · Biochemistry

The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.

Abstract

A quantitative description of transmembrane water transport requires specification of osmotic (Pf) and diffusional (Pd) water permeability coefficients. Methodology has been developed to measure Pf and Pd simultaneously on the basis of the sensitivity and rapid response of the fluorophore aminonaphthalenetrisulfonic acid (ANTS) to solution H2O/D2O content. Cells loaded with ANTS in an H2O buffer were subjected to an inward osmotic gradient with a D2O buffer in a stopped-flow apparatus. The time courses of cell volume (giving Pf) and H2O/D2O content (giving Pd) were recorded with dual photomultiplier detection of scattered light intensity and ANTS fluorescence, respectively. The method was validated by using sealed red cell ghosts and artificial liposomes reconstituted with the pore-forming agent gramicidin D. At 25 degrees C, red cell ghost Pf was 0.021 cm/s with Pd 0.005 cm/s (H2O/D2O exchange time 7.9 ms). Pf and Pd were inhibited by 90% and 45% upon addition of 0.5 mM HgCl2. The activation energy for Pd increased from 5.1 kcal/mol to 10 kcal/mol with addition of HgCl2 (18-35 degrees C). In 90% phosphatidylcholine (PC)/10% cholesterol liposomes prepared by bath sonication and exclusion chromatography, Pf and Pd were 5.1 X 10(-4) and 6.3 X 10(-4) cm/s, respectively (23 degrees C). Addition of gramicidin D (0.1 micrograms/mg of PC) resulted in a further increment in Pf and Pd of 7 X 10(-4) and 3 X 10(-4) cm/s, respectively. These results validate the new methodology and demonstrate its utility for rapid determination of Pf/Pd in biological membranes and in liposomes reconstituted with water channels.

Overview

Integrity signals

Registry

Crossref · 10.1021/bi00428a062

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 22 references

Cited by

Metadata

Authors
Ye, R., & Verkman, A. S.
Venue
Biochemistry
Published
1989-01-24
Volume
28
Issue
2
Pages
824-829
ISSN
  • 0006-2960 (ISSN-L)
  • 1520-4995
OpenAlex
W2014788725
Cited by
85
References
22
Citations by year
2026: 1 · 2025: 5 · 2024: 4 · 2022: 2 · 2020: 1 · 2019: 2 · 2018: 5 · 2017: 3 · 2016: 1 · 2015: 2 · 2014: 1 · 2013: 2
FWCI
0.77
Type
journal article
Language
en
Open access
closed
Locations
  • Biochemistry (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Institute of Diabetes and Digestive and Kidney Diseases (DK-39354, DK 35124)
Topics
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Ion Transport and Channel Regulation
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Lipid Membrane Structure and Behavior
  • Physical Sciences › Environmental Science › Water Science and Technology › Membrane Separation Technologies
Keywords
osmotic water permeability, erythrocyte ghosts, liposomes, gramicidin D, mercury chloride inhibition, activation energy, aquaporins, cell volume
MeSH terms
Cell Membrane Permeability, Cholesterol, Deuterium, Diffusion, Erythrocyte Membrane, Humans, Kinetics, Liposomes, Permeability, Spectrometry, Fluorescence, Water, Deuterium Oxide

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.