Synthesis and Characterization of Triblock Copolymers of Methoxy Poly(ethylene glycol) and Poly(propylene fumarate)
The DOI matches its Crossref record.
Abstract
Amphiphilic block copolymers were synthesized by transesterification of hydrophilic methoxy poly(ethylene glycol) (mPEG) and hydrophobic poly(propylene fumarate) (PPF) and characterized. Four block copolymers were synthesized with a 2:1 mPEG:PPF molar ratio and mPEGs of molecular weights 570, 800, 1960, and 5190 and PPF of molecular weight 1570 as determined by NMR. The copolymers synthesized with mPEG of molecular weights 570 and 800 had 1.9 and 1.8 mPEG blocks per copolymer, respectively, as measured by NMR, representing an ABA-type block copolymer. The number of mPEG blocks of the copolymer decreased with increasing mPEG block length to as low as 1.5 mPEG blocks for copolymer synthesized with mPEG of molecular weight 5190. At a concentration range of 5-25 wt % in phosphate-buffered saline, copolymers synthesized with mPEG molecular weights of 570 and 800 possessed lower critical solution temperatures (LCST) between 40 and 45 degrees C and between 55 and 60 degrees C, respectively. Aqueous solutions of copolymer synthesized with mPEG 570 and 800 also experienced thermoreversible gelation. The sol-gel transition temperature was dependent on the sodium chloride concentration as well as the mPEG block length. The copolymer synthesized from mPEG 570 had a transition temperature between 40 and 20 degrees C with salt concentrations between 1 and 10 wt %, while the sol-gel transition temperatures of the copolymer synthesized from mPEG molecular weight 800 were higher in the range 75-30 degrees C with salt concentrations between 1 and 15 wt %. These novel thermoreversible copolymers are the first biodegradable copolymers with unsaturated double bonds along their macromolecular chain that can undergo both physical and chemical gelation and hold great promise for drug delivery and tissue engineering applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hydrogels in drug delivery: Progress and challenges
Hoare, T. R., & Kohane, D. S. (2008) · Polymer · doi:10.1016/j.polymer.2008.01.027 · Cited by 3,776
Stimuli-reponsive polymers and their bioconjugates
GIL, E., & HUDSON, S. (2004) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2004.08.003 · Cited by 2,385
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Self-citationHydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
Hydrogels in a historical perspective: From simple networks to smart materials
Buwalda, S. J., Boere, K. W. M., Dijkstra, P. J., Feijen, J., Vermonden, T., & Hennink, W. E. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.052 · Cited by 994
In situ gelling stimuli-sensitive block copolymer hydrogels for drug delivery
He, C., Kim, S. W., & Lee, D. S. (2008) · Journal of Controlled Release · doi:10.1016/j.jconrel.2008.01.005 · Cited by 867
Injectable Biodegradable Hydrogels
Nguyen, M. K., & Lee, D. S. (2010) · Macromolecular Bioscience · doi:10.1002/mabi.200900402 · Cited by 481
Polymeric gels and hydrogels for biomedical and pharmaceutical applications
Jagur‐Grodzinski, J. (2010) · Polymers for Advanced Technologies · doi:10.1002/pat.1504 · Cited by 383
Yu, L., Zhang, Z., Zhang, H., & Ding, J. (2010) · Biomacromolecules · doi:10.1021/bm100549q · Cited by 179
Hydrogels for Musculoskeletal Tissue Engineering
Varghese, S., & Elisseeff, J. H. (2006) · Advances in Polymer Science · doi:10.1007/12_072 · Cited by 173
Thermo-responsive systems for controlled drug delivery
Bikram, M., & West, J. L. (2008) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.5.10.1077 · Cited by 169
“Since the development of these systems, there have been many other thermogelling systems synthesized including poly(ethylene glycol)-poly(caprolactone)-poly(ethylene glycol) (PEG-PCL-PEG) [97] , poly( ε -caprolactone-co-lactide)-poly (ethylene glycol)-poly( ε -caprolactone-co-lactide) (PCLA-PEGPCLA) [98] and triblock…”
BackgroundLoh, X. J., Tan, Y. X., Li, Z., Teo, L. S., Goh, S. H., & Li, J. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.01.016 · Cited by 158
Cai, Z., Wan, Y., Becker, M. L., Long, Y.-Z., & Dean, D. (2019) · Biomaterials · doi:10.1016/j.biomaterials.2019.03.038 · Cited by 133
Metadata
- Authors
- Behravesh, E., Shung, A. K., Jo, S., & Mikos, A. G.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-12-12
- Volume
- 3
- Issue
- 1
- Pages
- 153-158
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2029455834
- Cited by
- 86
- References
- 0
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.