Refolding Hydrogels Self-Assembled from N-(2-Hydroxypropyl)methacrylamide Graft Copolymers by Antiparallel Coiled-Coil Formation
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A novel hybrid hydrogel system based on N-(2-hydroxypropyl)methacrylamide copolymers was proposed. It consisted of the hydrophilic polymer backbone and a pair of oppositely charged peptide grafts. Two distinct pentaheptad peptides (CCE and CCK) were anticipated to create a dimerization motif and serve as physical cross-linkers. Consequently, the graft copolymers CCE-P and CCK-P self-assembled into hybrid hydrogels in situ; the process was modulated by the formation of antiparallel heterodimeric coiled-coils. This approach possesses an advantage to decrease the steric hindrance of the polymer backbone on the "in-register" alignment of peptide grafts. Indeed, equimolar mixtures of the graft copolymers, CCE-P/CCK-P, have been observed to self-assemble into hydrogels in PBS solution at neutral pH at concentrations as low as 0.1 wt %. Circular dichroism spectroscopy, sedimentation equilibrium experiments, and microrheology revealed that the self-assembly process corresponded to the two-stranded alpha-helical coiled-coil formation between CCE and CCK. Moreover, the formation of hybrid hydrogels was reversible. Denaturation of the coiled-coil domains with guanidine hydrochloride (GdnHCl) solutions resulted in disassembly of the hydrogels. Removal of GdnHCl by dialysis caused coiled-coil refolding and hydrogel reassembly. Scanning electron microscopy results demonstrated that the concentration of the graft copolymers had a significant impact on the structure and morphology of self-assembled hydrogels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
The Design of Coiled-Coil Structures and Assemblies
Woolfson, D. N. (2005) · Advances in Protein Chemistry · doi:10.1016/s0065-3233(05)70004-8 · Cited by 585
Cited by
Supramolecular polymeric hydrogels
Appel, E. A., del Barrio, J., Loh, X. J., & Scherman, O. A. (2012) · Chemical Society Reviews · doi:10.1039/c2cs35264h · Cited by 1,159
Hydrogel biomaterials: A smart future?
Kopeček, J. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2007.07.044 · Cited by 1,003
Self-citationHydrogels in a historical perspective: From simple networks to smart materials
Buwalda, S. J., Boere, K. W. M., Dijkstra, P. J., Feijen, J., Vermonden, T., & Hennink, W. E. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.03.052 · Cited by 994
Rheological properties of peptide-based hydrogels for biomedical and other applications
Yan, C., & Pochan, D. J. (2010) · Chemical Society Reviews · doi:10.1039/b919449p · Cited by 800
Smart polymeric gels: Redefining the limits of biomedical devices
Chaterji, S., Kwon, I. K., & Park, K. (2007) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2007.05.018 · Cited by 615
Metadata
- Authors
- Yang, J., Xu, C., Wang, C., & Kopeček, J.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-03-09
- Volume
- 7
- Issue
- 4
- Pages
- 1187-1195
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W340321564
- Cited by
- 150
- References
- 3
- FWCI
- 4.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Refolding Hydrogels Self-Assembled from N-(2-Hydroxypropyl)methacrylamide Graft Copolymers by Antiparallel Coiled-Coil Formation. https://app.cochat.ai/papers/10.1021/bm051002k
- The paper
- Yang, J., Xu, C., Wang, C., & Kopeček, J. (2006). Refolding Hydrogels Self-Assembled from N-(2-Hydroxypropyl)methacrylamide Graft Copolymers by Antiparallel Coiled-Coil Formation. Biomacromolecules. https://doi.org/10.1021/bm051002k
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.