Synthetic Biomimetic Hydrogels Incorporated with Ephrin-A1 for Therapeutic Angiogenesis
The DOI matches its Crossref record.
Abstract
Eph receptors and ephrin ligands are essential for vascular development and angiogenic remodeling. In this work, we developed biomimetic poly(ethylene glycol)-diacrylate hydrogels incorporated with ephrin-A1 and examined their angiogenic properties. Ephrin-A1 was covalently immobilized on the surface of hydrogels by chemical modification and photopolymerization. Ephrin-A1 immobilized on hydrogels was found to retain its capacity to stimulate endothelial cell adhesion in a dose-dependent manner as similar findings were observed on polystyrene culture wells pre-adsorbed with ephrin-A1. Cell adhesion stimulated by ephrin-A1 was abolished by treatment with soluble RGDS and anti-alpha(v)beta3 integrin but not anti-alpha(v)beta5 integrin antibodies, suggesting that ephrin-A1 activates cell adhesion through alpha(v)beta3 integrins. Also, surface immobilized ephrin-A1 was found to induce endothelial tubule formation with luminal diameters ranging 5-30 microm on hydrogels. The results of these studies demonstrate that pro-angiogenic properties of ephrin-A1 are preserved in hydrogels and suggest potential applications of this hydrogel system in regenerative medicine and tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Bioactive modification of poly (ethylene glycol) hydrogels for tissue engineering
Zhu, J. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.02.044 · Cited by 1,457
3D biofabrication strategies for tissue engineering and regenerative medicine
Bajaj, P., Schweller, R. M., Khademhosseini, A., West, J. L., & Bashir, R. (2014) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071813-105155 · Cited by 632
“Synthetic polymers have been similarly modified to utilize multiple photo-cross-linking mechanisms such as acrylate-acrylate (58, 59), thiol-ene (45, 60, 61), or thiol-yne (62, 63).”
BackgroundSelf-citationMelero-Martin, J. M., De Obaldia, M. E., Kang, S.-Y., Khan, Z. A., Yuan, L., Oettgen, P., & Bischoff, J. (2008) · Circulation Research · doi:10.1161/circresaha.108.178590 · Cited by 488
Microfluidic fabrication of microengineered hydrogels and their application in tissue engineering
Chung, B. G., Lee, K.-H., Khademhosseini, A., & Lee, S.-H. (2012) · Lab Chip · doi:10.1039/c1lc20859d · Cited by 435
Self-citationLee, S.-H., Moon, J. J., & West, J. L. (2008) · Biomaterials · doi:10.1016/j.biomaterials.2008.04.004 · Cited by 413
Self-citationEngineering the Regenerative Microenvironment with Biomaterials
Rice, J. J., Martino, M. M., De Laporte, L., Tortelli, F., Briquez, P. S., & Hubbell, J. A. (2013) · Advanced Healthcare Materials · doi:10.1002/adhm.201200197 · Cited by 389
The role of pore size on vascularization and tissue remodeling in PEG hydrogels
Chiu, Y.-C., Cheng, M.-H., Engel, H., Kao, S.-W., Larson, J. C., Gupta, S., & Brey, E. M. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.04.066 · Cited by 297
Naderi, H., Matin, M. M., & Bahrami, A. R. (2011) · Journal of Biomaterials Applications · doi:10.1177/0885328211408946 · Cited by 274
Bioartificial matrices for therapeutic vascularization
Phelps, E. A., Landázuri, N., Thulé, P. M., Taylor, W. R., & García, A. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0905447107 · Cited by 274
Knopf‐Marques, H., Pravda, M., Wolfova, L., Velebny, V., Schaaf, P., Vrana, N. E., & Lavalle, P. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600316 · Cited by 257
Achieving Controlled Biomolecule–Biomaterial Conjugation
Spicer, C. D., Pashuck, E. T., & Stevens, M. M. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00253 · Cited by 239
Vascularization of Engineered Tissues: Approaches to Promote Angiogenesis in Biomaterials
West, J., & Moon, J. (2008) · Current Topics in Medicinal Chemistry · doi:10.2174/156802608783790983 · Cited by 228
“In particular, ECs have been successfully cultured on RGDS grafted polymers, including hyaluronic acid hydrogels [36], derivatives of isopropylacrylamides [37,38], and PEG hydrogels [39].”
BackgroundSelf-citationBioactive hydrogels made from step-growth derived PEG–peptide macromers
Miller, J. S., Shen, C. J., Legant, W. R., Baranski, J. D., Blakely, B. L., & Chen, C. S. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.058 · Cited by 215
“Recent studies have shown promise via the encapsulation or immobilization of vascular endothelial growth factor (VEGF) [27– 29] or Ephrin-A1 [30] in these materials.”
BackgroundThree‐Dimensional Biomimetic Patterning in Hydrogels to Guide Cellular Organization
Culver, J. C., Hoffmann, J. C., Poché, R. A., Slater, J. H., West, J. L., & Dickinson, M. E. (2012) · Advanced Materials · doi:10.1002/adma.201200395 · Cited by 193
Self-citationBiomimetics in drug delivery systems: A critical review
Sheikhpour, M., Barani, L., & Kasaeian, A. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.026 · Cited by 177
Cell–cell communication mimicry with poly(ethylene glycol) hydrogels for enhancing β-cell function
Lin, C.-C., & Anseth, K. S. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014026108 · Cited by 172
“Some of these soluble receptors are in the form of fusion proteins, such as intercellular adhesion molecules 1 or ICAM-1 (16), E-cadherin (17), and ephrin–A1 (18) and have been used to create functional surfaces to enhance cell adhesion or to alter cell morphology.”
BackgroundSaik, J. E., Gould, D. J., Watkins, E. M., Dickinson, M. E., & West, J. L. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.08.018 · Cited by 168
“The effects of PEGylated proteins in 2D were studied by modifying the surface of bulk PEGDA hydrogels as previously described [20].”
MethodSelf-citationDesign principles for therapeutic angiogenic materials
Briquez, P. S., Clegg, L. E., Martino, M. M., Gabhann, F. M., & Hubbell, J. A. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2015.6 · Cited by 166
Evolution of PVA gels prepared without crosslinking agents as a cell adhesive surface
Gupta, S., Webster, T. J., & Sinha, A. (2011) · Journal of Materials Science: Materials in Medicine · doi:10.1007/s10856-011-4343-2 · Cited by 163
“It has been established by certain groups that particularly fibroblasts and epithelial cells prefer stiffer substrates to attach [49, 50].”
BackgroundKorrapati, P. S., Karthikeyan, K., Satish, A., Krishnaswamy, V. R., Venugopal, J. R., & Ramakrishna, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.05.074 · Cited by 102
Metadata
- Authors
- Moon, J. J., Lee, S.-H., & West, J. L.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-11-30
- Volume
- 8
- Issue
- 1
- Pages
- 42-49
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2032841803
- Cited by
- 103
- References
- 0
- FWCI
- 2.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.