Simultaneously Physically and Chemically Gelling Polymer System Utilizing a Poly(NIPAAm-co-cysteamine)-Based Copolymer
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The objective of this work was to create an in situ physically and chemically cross-linking hydrogel for in vivo applications. N-Isopropylacrylamide (NIPAAm) was copolymerized with N-acryloxysuccinimide (NASI) via free radical polymerization. Poly(NIPAAm-co-NASI) was further modified to obtain poly(NIPAAm-co-cysteamine) through a nucleophilic attack on the carbonyl group of the NASI by the amine group of the cysteamine. Modification was verified by nuclear magnetic resonance. In addition to thermoresponsive physical gelling due to the presence of NIPAAm, this system also chemically gels via a Michael-type addition reaction when mixed with poly(ethylene glycol) diacrylate. The presence of both physical and chemical gelation resulted in material properties that are much improved compared to purely physical gels. The chemical gelation time of the copolymers was not significantly affected by the amount of thiol present due to the increased pKa of the copolymer containing more thiols. In addition, the swelling of the copolymers was highly dependent on the temperature and thiol content. Last, the rate of nucleophilic attack in the Michael-type addition reaction was shown to be highly dependent on pH and on the mole ratio of thiol to acrylate. Due to the improved mechanical properties, this material may be better suited for long-term functional replacement applications than other thermosensitive physical gels. With further development and biocompatibility testing, this material could potentially be applied as a temperature-responsive injectable biomaterial for functional embolization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrogels for biomedical applications
Hoffman, A. S. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00239-3 · Cited by 4,864
Thermosensitive sol-gel reversible hydrogels
Jeong, B., Kim, S. W., & Bae, Y. H. (2002) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00242-3 · Cited by 1,478
In situ-forming hydrogels--review of temperature-sensitive systems
Ruel-Gariépy, E., & Leroux, J.-C. (2004) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2004.03.019 · Cited by 1,297
Lutolf, M. P., & Hubbell, J. A. (2003) · Biomacromolecules · doi:10.1021/bm025744e · Cited by 679
Cited by
The development of microgels/nanogels for drug delivery applications
Oh, J. K., Drumright, R., Siegwart, D. J., & Matyjaszewski, K. (2008) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2008.01.002 · Cited by 1,598
Thermoresponsive hydrogels in biomedical applications
Klouda, L., & Mikos, A. G. (2008) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2007.02.025 · Cited by 1,349
Hydrogels for Protein Delivery
Vermonden, T., Censi, R., & Hennink, W. E. (2012) · Chemical Reviews · doi:10.1021/cr200157d · Cited by 1,091
Synthetic polymer scaffolds for tissue engineering
Place, E. S., George, J. H., Williams, C. K., & Stevens, M. M. (2009) · Chemical Society Reviews · doi:10.1039/b811392k · Cited by 815
Thermoresponsive hydrogels in biomedical applications
Klouda, L. (2015) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2015.05.017 · Cited by 491
Das, A., & Theato, P. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00291 · Cited by 483
Recent progress of in situ formed gels for biomedical applications
Ko, D. Y., Shinde, U. P., Yeon, B., & Jeong, B. (2013) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.08.002 · Cited by 416
Polymeric gels and hydrogels for biomedical and pharmaceutical applications
Jagur‐Grodzinski, J. (2010) · Polymers for Advanced Technologies · doi:10.1002/pat.1504 · Cited by 383
Advances in Biomaterials and Technologies for Vascular Embolization
Hu, J., Albadawi, H., Chong, B. W., Deipolyi, A. R., Sheth, R. A., Khademhosseini, A., & Oklu, R. (2019) · Advanced Materials · doi:10.1002/adma.201901071 · Cited by 321
Injectable Biomaterials for Regenerating Complex Craniofacial Tissues
Kretlow, J. D., Young, S., Klouda, L., Wong, M., & Mikos, A. G. (2009) · Advanced Materials · doi:10.1002/adma.200802009 · Cited by 302
Bioactive factor delivery strategies from engineered polymer hydrogels for therapeutic medicine
Nguyen, M. K., & Alsberg, E. (2014) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2013.12.001 · Cited by 226
“A simultaneously physically and chemically gelling polymer system consisting of poly(NIPAm-co-cysteamine) and PEGDA was reported by another group [136].”
Yan, S., Wang, T., Feng, L., Zhu, J., Zhang, K., Chen, X., Cui, L., & Yin, J. (2014) · Biomacromolecules · doi:10.1021/bm501313t · Cited by 212
Overstreet, D. J., Dutta, D., Stabenfeldt, S. E., & Vernon, B. L. (2012) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.23081 · Cited by 199
Self-citationLeichner, C., Jelkmann, M., & Bernkop-Schnürch, A. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2019.04.007 · Cited by 163
Hacker, M. C., Klouda, L., Ma, B. B., Kretlow, J. D., & Mikos, A. G. (2008) · Biomacromolecules · doi:10.1021/bm8000414 · Cited by 104
Klouda, L., Perkins, K. R., Watson, B. M., Hacker, M. C., Bryant, S. J., Raphael, R. M., Kurtis Kasper, F., & Mikos, A. G. (2011) · Acta Biomaterialia · doi:10.1016/j.actbio.2010.12.027 · Cited by 75
Metadata
- Authors
- Robb, S. A., Lee, B. H., McLemore, R., & Vernon, B. L.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-06-13
- Volume
- 8
- Issue
- 7
- Pages
- 2294-2300
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2077710172
- Cited by
- 91
- References
- 4
- FWCI
- 4.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.