Evasion of the Accelerated Blood Clearance Phenomenon by Coating of Nanoparticles with Various Hydrophilic Polymers
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
The accelerated blood clearance (ABC) phenomenon is induced upon repeated injections of poly(ethylene glycol) (PEG)-coated colloidal carriers. It is essential to suppress this phenomenon in a clinical setting because the pharmacokinetics must be reproducible. In this study, we evaluated the induction of the ABC phenomenon using nanoparticles coated with various hydrophilic polymers instead of PEG. Nanoparticles encapsulating prostaglandin E1 were prepared by the solvent diffusion method from a blend of poly(lactic acid) (PLA) and block copolymers consisting of various hydrophilic polymers and PLA. Coating of nanoparticles with poly(N-vinyl-2-pyrrolidone) (PVP), poly(4-acryloylmorpholine), or poly(N,N-dimethylacrylamide) led to extended residence of the nanoparticles in blood circulation in rats, although they had a shorter half-life than the PEG-coated nanoparticles. The ABC phenomenon was not induced upon repeated injection of PVP-coated nanoparticles at various time intervals, dosages, or frequencies, whereas it was elicited by PEG-coated nanoparticles. In addition, anti-PVP IgM antibody, which is estimated to be one of the crucial factors for induction of the ABC phenomenon, was not produced after injection of PVP-coated nanoparticles. These results suggest that the use of PVP, instead of PEG, as a coating material for colloidal carriers can evade the ABC phenomenon.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tumor vascular permeability and the EPR effect in macromolecular therapeutics: a review
Maeda, H., Wu, J., Sawa, T., Matsumura, Y., & Hori, K. (2000) · Journal of Controlled Release · doi:10.1016/s0168-3659(99)00248-5 · Cited by 6,565
Recent advances with liposomes as pharmaceutical carriers
Torchilin, V. P. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1632 · Cited by 5,282
Nanoparticle therapeutics: an emerging treatment modality for cancer
Davis, M. E., Chen, Z., & Shin, D. M. (2008) · Nature Reviews Drug Discovery · doi:10.1038/nrd2614 · Cited by 4,233
Effect of pegylation on pharmaceuticals
Harris, J. M., & Chess, R. B. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1033 · Cited by 3,431
Wang, X., Ishida, T., & Kiwada, H. (2007) · Journal of Controlled Release · doi:10.1016/j.jconrel.2007.02.010 · Cited by 421
Self-citation
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Duan, X., & Li, Y. (2013) · Small · doi:10.1002/smll.201201390 · Cited by 926
The accelerated blood clearance (ABC) phenomenon: Clinical challenge and approaches to manage
Abu Lila, A. S., Kiwada, H., & Ishida, T. (2013) · Journal of Controlled Release · doi:10.1016/j.jconrel.2013.07.026 · Cited by 721
Self-citationAnti‐ PEG immunity: emergence, characteristics, and unaddressed questions
Yang, Q., & Lai, S. K. (2015) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1339 · Cited by 593
Shi, D., Beasock, D., Fessler, A., Szebeni, J., Ljubimova, J. Y., Afonin, K. A., & Dobrovolskaia, M. A. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.114079 · Cited by 535
PEGylated liposomes: immunological responses
Mohamed, M., Abu Lila, A. S., Shimizu, T., Alaaeldin, E., Hussein, A., Sarhan, H. A., Szebeni, J., & Ishida, T. (2019) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2019.1627174 · Cited by 523
Self-citationSustainable technologies for liposome preparation
Maja, L., Željko, K., & Mateja, P. (2020) · The Journal of Supercritical Fluids · doi:10.1016/j.supflu.2020.104984 · Cited by 398
Cleavable PEGylation: a strategy for overcoming the “PEG dilemma” in efficient drug delivery
Fang, Y., Xue, J., Gao, S., Lu, A., Yang, D., Jiang, H., He, Y., & Shi, K. (2017) · Drug Delivery · doi:10.1080/10717544.2017.1388451 · Cited by 386
Polymer–drug conjugates: Origins, progress to date and future directions
Kopeček, J. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2012.10.014 · Cited by 347
PEGylated Lipid Nanoparticle Formulations: Immunological Safety and Efficiency Perspective
Tenchov, R., Sasso, J. M., & Zhou, Q. A. (2023) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.3c00174 · Cited by 313
Stealth nanoparticles in oncology: Facing the PEG dilemma
Zalba, S., ten Hagen, T. L. M., Burgui, C., & Garrido, M. J. (2022) · Journal of Controlled Release · doi:10.1016/j.jconrel.2022.09.002 · Cited by 278
Kierstead, P. H., Okochi, H., Venditto, V. J., Chuong, T. C., Kivimae, S., Fréchet, J. M. J., & Szoka, F. C. (2015) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.06.023 · Cited by 210
“[36] Furthermore, Ishihara et. al. found that PVP nanoparticles that did not exhibit an ABC effect also did not initiate the production of anti-PVP IgM.”
InfluentialRecent Advances in Protein and Peptide Drug Delivery: A Special Emphasis on Polymeric Nanoparticles
Patel, A., Patel, M., Yang, X., & Mitra, A. (2014) · Protein & Peptide Letters · doi:10.2174/0929866521666140807114240 · Cited by 209
Understanding the immunogenicity and antigenicity of nanomaterials: Past, present and future
Ilinskaya, A. N., & Dobrovolskaia, M. A. (2016) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2016.01.005 · Cited by 209
“…et al., 2005; Ishida et al., 2006a; Ishida et al., 2006b; Ishida et al., 2006c; Ishida et al., 2007; Ishida et al., 2008; Ishida and Kiwada, 2008; Ishihara et al., 2010) and Kaminskas et al. (Kaminskas et al., 2011) suggested that anti-PEG IgM antibodies are responsible for the accelerated…”
BackgroundToxicity and immunogenicity concerns related to PEGylated-micelle carrier systems: a review
Shiraishi, K., & Yokoyama, M. (2019) · Science and Technology of Advanced Materials · doi:10.1080/14686996.2019.1590126 · Cited by 208
Extracellular vesicles as a drug delivery system: A systematic review of preclinical studies
Escudé Martinez de Castilla, P., Tong, L., Huang, C., Sofias, A. M., Pastorin, G., Chen, X., Storm, G., Schiffelers, R. M., & Wang, J.-W. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.011 · Cited by 208
Recent advances in long-acting drug delivery systems for anticancer drug
Pacheco, C., Baião, A., Ding, T., Cui, W., & Sarmento, B. (2023) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2023.114724 · Cited by 190
Current Approaches for Improving Intratumoral Accumulation and Distribution of Nanomedicines
Durymanov, M. O., Rosenkranz, A. A., & Sobolev, A. S. (2015) · Theranostics · doi:10.7150/thno.11742 · Cited by 189
Metadata
- Authors
- Ishihara, T., Maeda, T., Sakamoto, H., Takasaki, N., Shigyo, M., Ishida, T., Kiwada, H., Mizushima, Y., & Mizushima, T.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-08-26
- Volume
- 11
- Issue
- 10
- Pages
- 2700-2706
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2022257798
- Cited by
- 153
- References
- 5
- FWCI
- 3.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.