Biodegradation of Poly(2-hydroxyethyl methacrylate) (PHEMA) and Poly{(2-hydroxyethyl methacrylate)-co-[poly(ethylene glycol) methyl ether methacrylate]} Hydrogels Containing Peptide-Based Cross-Linking Agents
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PHEMA-peptide and P[HEMA-co-(MeO-PEGMA)]-peptide conjugate hydrogels [where PHEMA = poly(2-hydroxyethyl methacrylate; PEGMA = poly(ethylene glycol) methacrylate] were readily prepared via photoinitiated free-radical polymerization in water. The PHEMA-peptide hydrogels were opaque and had a heterogeneous morphology of interconnected polymer droplets, characteristic of polymers that separate from the aqueous phase during the polymerization experiment. The P[HEMA-co-(MeO-PEGMA)]-peptide conjugates were transparent gels with a homogeneous morphology when formed in water, but when formed in aqueous NaCl solutions the P[HEMA-co-(MeO-PEGMA)]-peptide conjugates were also opaque and exhibited the heterogeneous morphology of interconnected polymer droplets. When incubated in solutions containing activated papain, P[HEMA-co-(MeO-PEGMA)]-peptide conjugates underwent degradation that was characterized by macroscopic changes to sample shape and size, sample weight, and microscopic structure. PHEMA-peptide conjugates did not undergo any significant degradation when incubated with papain, although ninhydrin-staining experiments suggested that some peptide cross-linker groups were cleaved during the incubation. The difference in degradation behavior of PHEMA-peptide and P[HEMA-co-(MeO-PEGMA)]-peptide conjugates is attributed to differences in aqueous solubility of PHEMA and P[HEMA-co-(MeO-PEGMA)].
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hydrophilic gels for biological use
WICHTERLE, O., & LÍM, D. (1960) · Nature · doi:10.1038/185117a0 · Cited by 2,996
Polymeric systems for controlled drug release
Uhrich, K. E., Cannizzaro, S. M., Langer, R. S., & Shakesheff, K. M. (1999) · Chemical Reviews · doi:10.1021/cr940351u · Cited by 2,633
Cited by
Design properties of hydrogel tissue-engineering scaffolds
Zhu, J., & Marchant, R. E. (2011) · Expert Review of Medical Devices · doi:10.1586/erd.11.27 · Cited by 1,430
Designing degradable hydrogels for orthogonal control of cell microenvironments
Kharkar, P. M., Kiick, K. L., & Kloxin, A. M. (2013) · Chem. Soc. Rev. · doi:10.1039/c3cs60040h · Cited by 717
Zhang, Y., Chu, D., Zheng, M., Kissel, T., & Agarwal, S. (2012) · Polymer Chemistry · doi:10.1039/c2py20403g · Cited by 86
Fibers reinforced composite hydrogels with improved lubrication and load-bearing capacity
Li, J., Gao, L., Xu, R., Ma, S., Ma, Z., Liu, Y., Wu, Y., Feng, L., Cai, M., & Zhou, F. (2022) · Friction · doi:10.1007/s40544-020-0389-9 · Cited by 57
Metadata
- Authors
- Casadio, Y. S., Brown, D. H., Chirila, T. V., Kraatz, H.-B., & Baker, M. V.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2010-10-20
- Volume
- 11
- Issue
- 11
- Pages
- 2949-2959
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2054547965
- Cited by
- 56
- References
- 2
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.