Bioinspired Imprinted PHEMA-Hydrogels for Ocular Delivery of Carbonic Anhydrase Inhibitor Drugs
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Hydrogels with high affinity for carbonic anhydrase (CA) inhibitor drugs have been designed trying to mimic the active site of the physiological metallo-enzyme receptor. Using hydroxyethyl methacrylate (HEMA) as the backbone component, zinc methacrylate, 1- or 4-vinylimidazole (1VI or 4VI), and N-hydroxyethyl acrylamide (HEAA) were combined at different ratios to reproduce in the hydrogels the cone-shaped cavity of the CA, which contains a Zn(2+) ion coordinated to three histidine residues. 4VI resembles histidine functionality better than 1VI, and, consequently, pHEMA-ZnMA(2) hydrogels bearing 4VI moieties were those with the greatest ability to host acetazolamide or ethoxzolamide (2 to 3 times greater network/water partition coefficient) and to sustain the release of these antiglaucoma drugs (50% lower release rate estimated by fitting to the square root kinetics). The use of acetazolamide as template during polymerization did not enhance the affinity of the network for the drugs. In addition to the remarkable improvement in the performance as controlled release systems, the biomimetic hydrogels were highly cytocompatible and possessed adequate oxygen permeability to be used as medicated soft contact lenses or inserts. The results obtained highlight the benefits of mimicking the structure of the physiological receptors for the design of advanced drug delivery systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mechanisms of solute release from porous hydrophilic polymers
Korsmeyer, R. W., Gurny, R., Doelker, E., Buri, P., & Peppas, N. A. (1983) · International Journal of Pharmaceutics · doi:10.1016/0378-5173(83)90064-9 · Cited by 5,258
Structure and mechanism of carbonic anhydrase
Lindskog, S. (1997) · Pharmacology & Therapeutics · doi:10.1016/s0163-7258(96)00198-2 · Cited by 1,022
Challenges and obstacles of ocular pharmacokinetics and drug delivery
Urtti, A. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.07.027 · Cited by 1,003
Cited by
Whitcombe, M. J., Kirsch, N., & Nicholls, I. A. (2014) · Journal of Molecular Recognition · doi:10.1002/jmr.2347 · Cited by 445
Smart drug delivery systems: from fundamentals to the clinic
Alvarez-Lorenzo, C., & Concheiro, A. (2014) · Chem. Commun. · doi:10.1039/c4cc01429d · Cited by 415
Self-citationTopical drug delivery systems: a patent review
Singh Malik, D., Mital, N., & Kaur, G. (2016) · Expert Opinion on Therapeutic Patents · doi:10.1517/13543776.2016.1131267 · Cited by 192
“[74] drug-eluting contact lenses,[75] films,[24] NPs, [76] microemulsions,[22] microneedles,[77] etc.”
Ribeiro, A., Sosnik, A., Chiappetta, D. A., Veiga, F., Concheiro, A., & Alvarez-Lorenzo, C. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0102 · Cited by 91
Self-citationKang-Mieler, J. J., Dosmar, E., Liu, W., & Mieler, W. F. (2017) · Expert Opinion on Drug Delivery · doi:10.1080/17425247.2016.1227785 · Cited by 73
Fibers reinforced composite hydrogels with improved lubrication and load-bearing capacity
Li, J., Gao, L., Xu, R., Ma, S., Ma, Z., Liu, Y., Wu, Y., Feng, L., Cai, M., & Zhou, F. (2022) · Friction · doi:10.1007/s40544-020-0389-9 · Cited by 57
Metadata
- Authors
- Ribeiro, A., Veiga, F., Santos, D., Torres-Labandeira, J. J., Concheiro, A., & Alvarez-Lorenzo, C.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2011-02-11
- Volume
- 12
- Issue
- 3
- Pages
- 701-709
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2324165416
- Cited by
- 121
- References
- 3
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.