The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
In Situ Cross-Linking of Elastin-like Polypeptide Block Copolymers for Tissue Repair
Open accessAbstract
Rapid cross-linking of elastin-like polypeptides (ELPs) with hydroxymethylphosphines (HMPs) in aqueous solution is attractive for minimally invasive in vivo implantation of biomaterials and tissue engineering scaffolds. In order to examine the independent effect of the location and number of reactive sites on the chemical cross-linking kinetics of ELPs and the mechanical properties of the resulting hydrogels, we have designed ELP block copolymers comprised of cross-linkable, hydrophobic ELP blocks with periodic Lys residues (A block) and aliphatic, hydrophilic ELP blocks with no cross-linking sites (B block); three different block architectures, A, ABA, and BABA were synthesized in this study. All ELP block copolymers were rapidly cross-linked with HMPs within several minutes under physiological conditions. The inclusion of the un-cross-linked hydrophilic block, its length relative to the cross-linkable hydrophobic block, and the block copolymer architecture all had a significant effect on swelling ratios of the cross-linked hydrogels, their microstructure, and mechanical properties. Fibroblasts embedded in the ELP hydrogels survived the cross-linking process and remained viable for at least 3 days in vitro when the gels were formed from an equimolar ratio of HMPs and Lys residues of ELPs. DNA quantification of the embedded cells indicated that the cell viability within triblock ELP hydrogels was statistically greater than that in the monoblock gels at day 3. These results suggest that the mechanical properties of ELP hydrogels and the microenvironment that they present to cells can be tuned by the design of the block copolymer architecture.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lutolf, M. P., & Hubbell, J. A. (2005) · Nature Biotechnology · doi:10.1038/nbt1055 · Cited by 4,551
Designing materials for biology and medicine
Langer, R., & Tirrell, D. A. (2004) · Nature · doi:10.1038/nature02388 · Cited by 3,198
Cited by
Biomedical applications of biodegradable polymers
Ulery, B. D., Nair, L. S., & Laurencin, C. T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22259 · Cited by 2,206
Injectable and biodegradable hydrogels: gelation, biodegradation and biomedical applications
Li, Y., Rodrigues, J., & Tomás, H. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15203c · Cited by 1,445
25th Anniversary Article: Rational Design and Applications of Hydrogels in Regenerative Medicine
Annabi, N., Tamayol, A., Uquillas, J. A., Akbari, M., Bertassoni, L. E., Cha, C., Camci‐Unal, G., Dokmeci, M. R., Peppas, N. A., & Khademhosseini, A. (2014) · Advanced Materials · doi:10.1002/adma.201303233 · Cited by 1,409
Chemically Modified Biopolymers for the Formation of Biomedical Hydrogels
Muir, V. G., & Burdick, J. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00923 · Cited by 604
Peptide- and Protein-Based Hydrogels
Jonker, A. M., Löwik, D. W. P. M., & van Hest, J. C. M. (2012) · Chemistry of Materials · doi:10.1021/cm202640w · Cited by 504
Metadata
- Authors
- Lim, D. W., Nettles, D. L., Setton, L. A., & Chilkoti, A.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-29
- Volume
- 9
- Issue
- 1
- Pages
- 222-230
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2102893683
- Cited by
- 162
- References
- 2
- FWCI
- 6.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.