The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An Acid-Labile Block Copolymer of PDMAEMA and PEG as Potential Carrier for Intelligent Gene Delivery Systems
Abstract
Intelligent gene delivery systems based on physiologically triggered reversible shielding technology have evinced enormous interest due to their potential in vivo applications. In the present work, an acid-labile block copolymer consisting of poly(ethylene glycol) and poly(2-(dimethylamino)ethyl methacrylate) segments connected through a cyclic ortho ester linkage (PEG- a-PDMAEMA) was synthesized by atom transfer radical polymerization of DMAEMA using a PEG macroinitiator with an acid-cleavable end group. PEG- a-PDMAEMA condensed with plasmid DNA formed polyplex nanoparticles with an acid-triggered reversible PEG shield. The pH-dependent shielding/deshielding effect of PEG chains on the polyplex particles were evaluated by zeta potential and size measurements. At pH 7.4, polyplexes generated from PEG- a-PDMAEMA exhibited smaller particle size, lower surface charge, reduced interaction with erythrocytes, and less cytotoxicity compared to PDMAEMA-derived polyplexes. At pH 5.0, zeta potential of polyplexes formed from PEG- a-PDMAEMA increased, leveled up after 2 h of incubation and gradual aggregation occurred in the presence of bovine serum albumin (BSA). In contrast, the stably shielded polyplexes formed by DNA and an acid-stable block copolymer, PEG- b-PDMAEMA, did not change in size and zeta potential in 6 h. In vitro transfection efficiency of the acid-labile copolymer greatly increased after 6 h incubation at pH 5.0, approaching the same level of PDMAEMA, whereas there was only slight increase in efficiency for the stable copolymer, PEG- b-PDMAEMA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and development of polymers for gene delivery
Pack, D. W., Hoffman, A. S., Pun, S., & Stayton, P. S. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1775 · Cited by 2,568
Ogris, M., Brunner, S., Schüller, S., Kircheis, R., & Wagner, E. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300900 · Cited by 1,178
Dash, P. R., Read, M. L., Barrett, L. B., Wolfert, M. A., & Seymour, L. W. (1999) · Gene Therapy · doi:10.1038/sj.gt.3300843 · Cited by 386
Cited by
Sharifi, S., Behzadi, S., Laurent, S., Laird Forrest, M., Stroeve, P., & Mahmoudi, M. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15188f · Cited by 1,460
Stimuli-Responsive Polymersomes for Programmed Drug Delivery
Meng, F., Zhong, Z., & Feijen, J. (2009) · Biomacromolecules · doi:10.1021/bm801127d · Cited by 1,122
Mechanisms and biomaterials in pH-responsive tumour targeted drug delivery: A review
Kanamala, M., Wilson, W. R., Yang, M., Palmer, B. D., & Wu, Z. (2016) · Biomaterials · doi:10.1016/j.biomaterials.2016.01.061 · Cited by 1,004
Ge, Z., & Liu, S. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60048c · Cited by 914
pH- and ion-sensitive polymers for drug delivery
Yoshida, T., Lai, T. C., Kwon, G. S., & Sako, K. (2013) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2013.821978 · Cited by 367
Metadata
- Authors
- Lin, S., Du, F., Wang, Y., Ji, S., Liang, D., Yu, L., & Li, Z.
- Venue
- Biomacromolecules
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-12-19
- Volume
- 9
- Issue
- 1
- Pages
- 109-115
- ISSN
- 1525-7797 (ISSN-L)
- 1526-4602
- OpenAlex
- W2068668897
- Cited by
- 225
- References
- 3
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Acid-Labile Block Copolymer of PDMAEMA and PEG as Potential Carrier for Intelligent Gene Delivery Systems. https://app.cochat.ai/papers/10.1021/bm7008747
- The paper
- Lin, S., Du, F., Wang, Y., Ji, S., Liang, D., Yu, L., & Li, Z. (2008). An Acid-Labile Block Copolymer of PDMAEMA and PEG as Potential Carrier for Intelligent Gene Delivery Systems. Biomacromolecules. https://doi.org/10.1021/bm7008747
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.