Uptake and Transport of Superparamagnetic Iron Oxide Nanoparticles through Human Brain Capillary Endothelial Cells
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The blood-brain barrier (BBB) formed by brain capillary endothelial cells (BCECs) constitutes a firm physical, chemical, and immunological barrier, making the brain accessible to only a few percent of potential drugs intended for treatment inside the central nervous system. With the purpose of overcoming the restraints of the BBB by allowing the transport of drugs, siRNA, or DNA into the brain, a novel approach is to use superparamagnetic iron oxide nanoparticles (SPIONs) as drug carriers. The aim of this study was to investigate the ability of fluorescent SPIONs to pass through human brain microvascular endothelial cells facilitated by an external magnet. The ability of SPIONs to penetrate the barrier was shown to be significantly stronger in the presence of an external magnetic force in an in vitro BBB model. Hence, particles added to the luminal side of the in vitro BBB model were found in astrocytes cocultured at a remote distance on the abluminal side, indicating that particles were transported through the barrier and taken up by astrocytes. Addition of the SPIONs to the culture medium did not negatively affect the viability of the endothelial cells. The magnetic force-mediated dragging of SPIONs through BCECs may denote a novel mechanism for the delivery of drugs to the brain.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Monopoli, M. P., Walczyk, D., Campbell, A., Elia, G., Lynch, I., Baldelli Bombelli, F., & Dawson, K. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja107583h · Cited by 1,835
Transferrin receptor on endothelium of brain capillaries
Jefferies, W. A., Brandon, M. R., Hunt, S. V., Williams, A. F., Gatter, K. C., & Mason, D. Y. (1984) · Nature · doi:10.1038/312162a0 · Cited by 1,061
Laurent, S., Burtea, C., Thirifays, C., Häfeli, U. O., & Mahmoudi, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0029997 · Cited by 171
Differential receptor-mediated drug targeting to the diseased brain
Rip, J., Schenk, G., & de Boer, A. (2009) · Expert Opinion on Drug Delivery · doi:10.1517/17425240902806383 · Cited by 98
Cited by
Iron Oxide Nanoparticles for Magnetically-Guided and Magnetically-Responsive Drug Delivery
Estelrich, J., Escribano, E., Queralt, J., & Busquets, M. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16048070 · Cited by 532
Functionalized Nanomaterials Capable of Crossing the Blood–Brain Barrier
Zha, S., Liu, H., Li, H., Li, H., Wong, K.-L., & All, A. H. (2024) · ACS Nano · doi:10.1021/acsnano.3c10674 · Cited by 378
Strategies for transporting nanoparticles across the blood–brain barrier
Zhang, T.-T., Li, W., Meng, G., Wang, P., & Liao, W. (2016) · Biomaterials Science · doi:10.1039/c5bm00383k · Cited by 308
Nano carriers for drug transport across the blood–brain barrier
Li, X., Tsibouklis, J., Weng, T., Zhang, B., Yin, G., Feng, G., Cui, Y., Savina, I. N., Mikhalovska, L. I., Sandeman, S. R., et al. (2017) · Journal of Drug Targeting · doi:10.1080/1061186x.2016.1184272 · Cited by 282
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209
Challenges and opportunities to penetrate the blood-brain barrier for brain cancer therapy
Upton, D. H., Ung, C., George, S. M., Tsoli, M., Kavallaris, M., & Ziegler, D. S. (2022) · Theranostics · doi:10.7150/thno.69682 · Cited by 182
Organ-specific toxicity of magnetic iron oxide-based nanoparticles
Chrishtop, V. V., Mironov, V. A., Prilepskii, A. Y., Nikonorova, V. G., & Vinogradov, V. V. (2021) · Nanotoxicology · doi:10.1080/17435390.2020.1842934 · Cited by 86
Nowak-Jary, J., & Machnicka, B. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms252212013 · Cited by 74
A Promising Approach: Magnetic Nanosystems for Alzheimer’s Disease Theranostics
Chaparro, C. I. P., Simões, B. T., Borges, J. P., Castanho, M. A. R. B., Soares, P. I. P., & Neves, V. (2023) · Pharmaceutics · doi:10.3390/pharmaceutics15092316 · Cited by 40
Gupta, R., Chauhan, A., Kaur, T., Kuanr, B. K., & Sharma, D. (2022) · Nanoscale · doi:10.1039/d2nr02210a · Cited by 35
Metadata
- Authors
- Thomsen, L. B., Linemann, T., Pondman, K. M., Lichota, J., Kim, K. S., Pieters, R. J., Visser, G. M., & Moos, T.
- Venue
- ACS Chemical Neuroscience
- Publisher
- American Chemical Society (ACS)
- Published
- 2013-08-26
- Volume
- 4
- Issue
- 10
- Pages
- 1352-1360
- ISSN
- 1948-7193 (ISSN-L)
- OpenAlex
- W2024668700
- Cited by
- 80
- References
- 4
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.