The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Electrochemical and Spectroscopic Study of Arsenate Removal from Water Using Zero-Valent Iron Media
Abstract
This study investigated the mechanisms involved in removing arsenate from drinking water supplies using zero-valent iron media. Batch experiments utilizing iron wires suspended in anaerobic arsenate solutions were performed to determine arsenate removal rates as a function of the arsenate solution concentration. Corrosion rates of the iron wires were determined as a function of elapsed time using Tafel analysis. The removal kinetics in the batch reactors were best described by a dual-rate model in which arsenate removal was pseudo-first-order at low concentrations and approached zero-order in the limit of high arsenate concentrations. The presence of arsenate decreased iron corrosion rates as compared to those in blank 3 mM CaSO4 background electrolyte solutions. However, constant corrosion rates were attained after approximately 10 days elapsed, indicating that the passivation processes had reached steady state. The cathodic Tafel slopes were the same in the arsenate and the blank electrolyte solutions. This indicates that water was the primary oxidant for iron corrosion and that arsenate did not directly oxidize the iron wires. The anodic Tafel slopes were greater in the arsenate solutions, indicating that arsenate formed complexes with iron corrosion products released at anodic sites on the iron surfaces. Ion chromatography analyses indicated that there was no measurable reduction of As(V) to As(III). X-ray absorption spectroscopy analyses indicated that all arsenic associated with the zero-valent iron surfaces was in the oxidation state. Interatomic arsenic-iron distances determined from EXAFS analyses were consistent with bidentate corner-sharing among arsenate tetrahedra and iron octahedra. Results from this study show that under conditions applicable to drinking water treatment, arsenate removal by zero-valent iron media involves surface complexation only and does not involve reduction to metallic arsenic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Arsenate and Chromate Retention Mechanisms on Goethite. 1. Surface Structure
Fendorf, S., Eick, M. J., Grossl, P., & Sparks, D. L. (1997) · Environmental Science & Technology · doi:10.1021/es950653t · Cited by 1,017
Cited by
Arsenic removal from water/wastewater using adsorbents—A critical review
Mohan, D., & Pittman, C. U. (2007) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2007.01.006 · Cited by 3,536
Leupin, O. X., & Hug, S. J. (2005) · Water Research · doi:10.1016/j.watres.2005.02.012 · Cited by 421
Intraparticle diffusion and adsorption of arsenate onto granular ferric hydroxide (GFH)
Badruzzaman, M., Westerhoff, P., & Knappe, D. R. U. (2004) · Water Research · doi:10.1016/j.watres.2004.07.007 · Cited by 366
Iron and aluminium based adsorption strategies for removing arsenic from water
Giles, D. E., Mohapatra, M., Issa, T. B., Anand, S., & Singh, P. (2011) · Journal of Environmental Management · doi:10.1016/j.jenvman.2011.07.018 · Cited by 345
Hussam, A., & Munir, A. K. M. (2007) · Journal of Environmental Science and Health, Part A · doi:10.1080/10934520701567122 · Cited by 254
Metadata
- Authors
- Farrell, J., Wang, J., O'Day, P., & Conklin, M.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2001-04-06
- Volume
- 35
- Issue
- 10
- Pages
- 2026-2032
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2011254808
- Cited by
- 249
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrochemical and Spectroscopic Study of Arsenate Removal from Water Using Zero-Valent Iron Media. https://app.cochat.ai/papers/10.1021/es0016710
- The paper
- Farrell, J., Wang, J., O'Day, P., & Conklin, M. (2001). Electrochemical and Spectroscopic Study of Arsenate Removal from Water Using Zero-Valent Iron Media. Environmental Science & Technology. https://doi.org/10.1021/es0016710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.