Analysis for Perfluorocarboxylic Acids/Anions in Surface Waters and Precipitation Using GC−MS and Analysis of PFOA from Large-Volume Samples
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The presence of perfluorocarboxylates (PFCAs) in the environment is of increasing concern, following the discovery of perfluoroalkyl acids (PFAs) in wildlife and human samples. Here we report a method forthe determination of (C2-C9) PFCAs by preparing the 2,4-difluoroanilides of the acids and analyzing by using GC-MS. Detector response was linear over the range 0.1 -1000 pg of each perfluoroalkyl anilide. A complete suite of PFCAs can be analyzed in an individual sample with the PFCAs detected at levels similar to or lower than those determined by other methods. For a comparison between the present method and the more common LC-MS/MS method, 10 replicates of a sewage treatment plant discharge were analyzed for perfluoro-octanoic acid (PFOA) using both methods. Results were nearly identical with low standard deviation (GC-MS 30.9 +/- 1.88 ng/L; while the LC-MS/MS 34.7 +/- 3.05 ng/L). PFCA concentrations for water samples collected from depth profiles in mid-Lake Ontario were analyzed by GC-MS with most PFCAs (C2-C8) present above the detection limit (0.5 ng/L). Major PFCAs were trifluoroacetate (TFA) (100 ng/L) and perfluorobutanoate (PFBA) (> 5 ng/L). Results for PFOA (2.5 ng/L) were in good agreement with recent analyses by LC-MS/MS. PFCAs were also detected in the precipitation samples at concentrations lower than those of the samples from the lake profiles or sewage treatment plants (STPs) effluent. Since PFOA levels may be less than the lower detection limit (<0.5 ng/L) in 1 L samples, a method for large volumes using XAD-7 resin was developed that allows detection to 0.01 ng/L. This method was applied to Lake Superior samples which produced good agreement for C6-C9 PFCAs between regular analysis (GC-MS) and the XAD-7 followed by GC-MS analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Global Distribution of Perfluorooctane Sulfonate in Wildlife
Giesy, J. P., & Kannan, K. (2001) · Environmental Science & Technology · doi:10.1021/es001834k · Cited by 2,750
Detection of perfluorooctane surfactants in Great Lakes water
Boulanger, B., Vargo, J., Schnoor, J. L., & Hornbuckle, K. C. (2004) · Environmental Science & Technology · doi:10.1021/es0496975 · Cited by 299
Ratio of perfluorochemical concentrations as a tracer of atmospheric deposition to surface waters
Simcik, M. F., & Dorweiler, K. J. (2005) · Environmental Science & Technology · doi:10.1021/es0511218 · Cited by 202
Cited by
The overlooked short- and ultrashort-chain poly- and perfluorinated substances: A review
Ateia, M., Maroli, A., Tharayil, N., & Karanfil, T. (2019) · Chemosphere · doi:10.1016/j.chemosphere.2018.12.186 · Cited by 639
Treatment technologies for aqueous perfluorooctanesulfonate (PFOS) and perfluorooctanoate (PFOA)
Vecitis, C. D., Park, H., Cheng, J., Mader, B. T., & Hoffmann, M. R. (2009) · Frontiers of Environmental Science & Engineering in China · doi:10.1007/s11783-009-0022-7 · Cited by 436
Recent advances in the analysis of per- and polyfluoroalkyl substances (PFAS)—A review
Al Amin, M., Sobhani, Z., Liu, Y., Dharmaraja, R., Chadalavada, S., Naidu, R., Chalker, J. M., & Fang, C. (2020) · Environmental Technology & Innovation · doi:10.1016/j.eti.2020.100879 · Cited by 334
Park, H., Vecitis, C. D., Cheng, J., Choi, W., Mader, B. T., & Hoffmann, M. R. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp807116q · Cited by 305
Water Analysis: Emerging Contaminants and Current Issues
Richardson, S. D. (2007) · Analytical Chemistry · doi:10.1021/ac070719q · Cited by 233
Metadata
- Authors
- Scott, B. F., Moody, C. A., Spencer, C., Small, J. M., Muir, D. C. G., & Mabury, S. A.
- Venue
- Environmental Science & Technology
- Publisher
- American Chemical Society (ACS)
- Published
- 2006-09-14
- Volume
- 40
- Issue
- 20
- Pages
- 6405-6410
- ISSN
- 0013-936X (ISSN-L)
- 1520-5851
- OpenAlex
- W2058335098
- Cited by
- 147
- References
- 3
- FWCI
- 7.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.